User manual XTANT 603X

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual XTANT 603X. We hope that this XTANT 603X user guide will be useful to you.


XTANT 603X : Download the complete user guide (453 Ko)

You may also download the following manuals related to this product:

   XTANT 603X INSTALLATION (117 ko)

Manual abstract: user guide XTANT 603X

Detailed instructions for use are in the User's Guide.

[. . . ] Vivid mobile audio, a continuing evolution of the art of listing and hearing, well. We have united art of the technology and the technology of the art to create the magic. Xtant is only available through the finest specialized mobile audio retailers. Your Xtant Select Dealer was chosen by us because of their passion for excellence and their commitment to expanding their expertise. [. . . ] Refer to page 7 of this manual for a list of the available frequencies. Balanced / Floating Input: The 603x offers a built on board balanced input stage. When placed in the enable position this circuitry helps to eliminate "system noise" associated with "ground-loops". Additionally the balanced input allows the 603x to accept input voltage from 100mV to 17V. Modular Expansion Port: All Xtant amplifiers are supplied with a modular port used for docking any of Xtant's signal processing modules. Protection Circuitry: Both Thermal and Overcurrent protection has been incorporated into all Xtant amplifiers. In the event of a problem, the amplifier will reduce its power to maintain operation. Status LEDs: Four LEDs, visible through the cover, indicate operational status of all Xtant amplifiers. The red LED illuminates when the amplifier is "ON", the green LED indicates when the noise gate is open, the yellow LED indicates that overcurrent protection is employed and the orange LED indicates that the thermal protection circuit is operational. 5 Xtant 603x SPECIFICATIONS Frequency Response Number of Channels Watts per Channel @ 4 Watts per Channel @ 2 Bridged Mono @ 4 (Stereo Channels) 5 Hz to 50 kHz +/­ 1 dB 3 2 x 75 + 1 x 150 2 x 150 + 1 x 300 1 x 300 Recommended Load (stereo channels) >2 Stereo / >4 Bridged Recommended Load (Mono channel) Distortion (THD) Signal to Noise Ratio Damping Factor Input Sensitivity >2 < . 04% > 100 dB > 200 @ 100 Hz with 4 load 100 mV to 8. 5 V RMS Unbalanced Source 100 mV to 17 V RMS Balanced Source Measured: 20 Hz to 20 kHz at rated power, all channels driven 4 Measured: A-weighted in 20 kHz noise bandwidth @ 1 volt sensitivity Input to Line Output Gain 0 dB +/­ 20 dB, Selectable in 10 dB steps On-Board Crossover Module Port(s) Power Supply Operational Voltage Fusing Warranty SEE PAGE ELEVEN OF THIS 12 dB (Butterworth) or 24dB (Linkwitz-Reily) 4 Fully Regulated, PWM 11 to 15 Volts Requires 100 Amp Limited 4 Year Parts and Labor MANUAL FOR COMPLETE D E TA I L S 6 ON-BOARD ELECTRONIC CROSSOVER All Xtant "x", and "ix" Series 2 channel amplifiers have onboard, two-way electronic crossovers. Xtant 3 and 4 channel models feature two independent two-way crossovers. Each crossover is tied to a set of inputs and controls the frequency range of the associated amplifier. Independent frequency selection is provided for both the High and Low Pass sections. A set of selectable RCA line outputs (to feed additional components) are included with each crossover. In addition, each crossover features two on-board header jumpers (one for the amplifier and one for the RCA line outputs) which allow you to select Bypass (Full Range), High Pass, and/or Low Pass modes. The "ix" Series models offer an additional Band Pass selection. When chosen, the Band Pass selection is available via the Low Pass jumper position for the RCA line outputs. The following Frequency Modules (SIPs)* are available from your Xtant Dealer: 50 Hz, 70 Hz, 80 Hz, 90 Hz, 120 Hz, 150 Hz, 300 Hz, 500 Hz, 700 Hz, 1 kHz, 3 kHz, 4 kHz, and 5 kHz. Please refer to the Installer's Reference (insert) for the Frequency Module receptacle location and chart of frequency/SIP value code numbers * SIP: an acronym referring to multiple resistors in a Single In-Line Package 7 OPTIONAL ACCESSORY MODULES Xtant optional accessory modules are easily and quickly installable by your Authorized Xtant Dealer. The upgrade modules snap into place on the amplifiers PC board when the top of the unit is removed. These accessories enhance your entire system, expanding and customizing performance for your unique applications. PARAMETRIC EQUALIZATION MODULE ­ PQM 1 The PQM-1 is a precision tuning instrument, designed to be adjusted with the use of a Real-Time-Analyzer. This true, fully adjustable, one band parametric equalizer provides individual frequency, Q/bandwidth, and +/- 18dB gain adjustment controls. [. . . ] If improper operation of your Xtant product should occur, contact your Authorized Xtant Dealer for assistance with the return and factory repair of your Xtant product. If an Authorized Xtant Dealer is not available, please contact Xtant's Customer Service Department for assistance. ELECTRONICS X t a n t Te c h n o l o g i e s 7676 South 46th Street Phoenix, Arizona 85040 888-449-8268 SPEAKERS X t a n t Te c h n o l o g i e s 805 Woodman Ave. Winslow, Il 61089 800-556-2888 TO RETURN XTANT PRODUCTS OUT OF WARRANTY: Contact Xtant's Warranty Department at (602) 431 8686 from 8:00 am to 5:00 pm (MST) for a Return Authorization Number. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE XTANT 603X




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual XTANT 603X will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.