User manual WHIRLPOOL WRF532SMBW DIMENSION GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL WRF532SMBW. We hope that this WHIRLPOOL WRF532SMBW user guide will be useful to you.


WHIRLPOOL WRF532SMBW DIMENSION GUIDE: Download the complete user guide (91 Ko)

You may also download the following manuals related to this product:

   WHIRLPOOL WRF532SMBW ENERGY GUIDE (117 ko)
   WHIRLPOOL WRF532SMBW USE & CARE GUIDE (1539 ko)
   WHIRLPOOL WRF532SMBW WARRANTY INFORMATION (93 ko)

Manual abstract: user guide WHIRLPOOL WRF532SMBWDIMENSION GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] An optional stainless steel panel kit (SPKCMD-1) can be field installed. It contains a stainless steel top, side panels, service panels, and front panel. · *BH550 · *HTB500, HTB350, HTB250 · BH800 (with bin top KBT23) · BH900 (with bin top KTB22) · BH1360 It will also fit these Scotsman Dispensers: · CD200 · IS150 (with adapter kit KADCM1) · RS150 (with adapter kit KADCM1) *These smaller bins are recommended. Scotsman Ice Systems are designed and manufactured with the highest regard for safety and performance. Scotsman assumes no liability or responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use of any parts and/or other components not specifically approved by Scotsman. [. . . ] Water Distribution System The water distribution system evenly supplies water to all cells of the evaporator plates. The water pump pumps water from the sump up the vertical tygon tube to the tee. From there water is channeled through the water manifold to the water distributors, above each evaporator plate, and from six holes within each distributor, water flows to the cells of each side of the evaporator plates. Gravity flow returns the unfrozen excess portion of water to the sump reservoir for recirculation. Water Distribution System Water System Components Water Inlet Valve Water Pump March 1994 Page 14 WRF532SMBW INITIAL START UP Before Start Up: 1. Check that the Master ON-OFF switch and the Compressor ON-OFF switch are in the OFF position. Electrical power must be supplied to the ice machine for 4 hours before starting the compressor for the first time. The oil is warmed to evaporate any refrigerant that may have collected in it. If there is refrigerant in the oil when the compressor starts, the oil will foam and will not lubricate the compressor properly, shortening its life. Do not start the compressor for the first time unless the dome of the compressor is warm. Rotate the shaft of the timer and switch assembly clockwise to start the timer. The timer starts when the actuator arm on the microswitch drops off outer cam into cam slot. At the beginning of the freezing cycle, the electrical circuit is completed to the compressor and the water pump. The water pump operates continuously, through both the freezing cycle and the harvest cycle. During the freezing cycle, the hot gas solenoid valve is CLOSED and the water inlet solenoid valve is CLOSED. When the ice cubes are partially formed, the cube size control will sense the temperature at which it is preset to CLOSE. The timer will keep the icemaker operating in the freezing cycle for a selected length of time. After that selected length of time, the timer will switch the icemaker into the harvest cycle, through the contacts of the timer assembly microswitch. Low Temperature Freeze: When the outside air temperature is low, the Head Pressure Regulator will close off the liquid line to the receiver, causing liquid refrigerant to back up into the condenser until the head pressure builds up to 240 PSIG. While this is occurring, the head pressure regulator passes discharge gas into the receiver to keep the refrigerant flowing. REFRIGERATION SCHEMATIC Liquid Line Fan Motor Discharge Line Head Pressure Control Valve Discharge Coil Heat Exchange Filter Hot Gas Valve (Closed) Suction Line Receiver Compressor Crankcase Heater Liquid Line Valve Water Valve (Closed) Filter/Dryer TXV Evaporators Pump King Valve Drain October 1994 Page 17 WRF532SMBW HARVEST CYCLE - HOT GAS BYPASS When the timer switches the icemaker into the harvest cycle, high pressure, high temperature refrigerant gas discharged from the compressor flows through the hot gas solenoid valve into each evaporator plate. In the electrical circuit, both the compressor and the water pump are operating. Both the hot gas solenoid valve and the water inlet solenoid valve are OPEN. The finished ice cubes are released from the sides of each evaporator plate by the warming effect of the hot gas condensing in each evaporator plate and the water cascading over the ice cubes. [. . . ] · HP62 is a "Near Azeotrope", and therefore liquid charging is required. ¤ Weigh as much of the charge as liquid into the receiver as possible. ¤ Install a sight glass between the suction service valve and the gage manifold. Use the manifold valve to "flash off" liquid before it enters the ice machine's refrigeration system. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WRF532SMBW




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WRF532SMBW will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.