User manual WHIRLPOOL WMH32519CS INSTALLATION GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL WMH32519CS. We hope that this WHIRLPOOL WMH32519CS user guide will be useful to you.


WHIRLPOOL WMH32519CS INSTALLATION GUIDE: Download the complete user guide (414 Ko)

You may also download the following manuals related to this product:

   WHIRLPOOL WMH32519CS (220 ko)
   WHIRLPOOL WMH32519CS DIMENSION GUIDE (84 ko)
   WHIRLPOOL WMH32519CS QUICK REFERENCE SHEET (81 ko)

Manual abstract: user guide WHIRLPOOL WMH32519CSINSTALLATION GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] PRODUCT DIMENSIONS VENTING DESIGN SPECIFICATIONS This section is intended for architectural designer and builder/contractor reference only. NOTES: Vent materials needed for installation are not provided with microwave hood combination. q To avoid possible product damage, be sure to vent air outside, unless using recirculation installation. [. . . ] Do not vent exhaust air into concealed spaces, such as spaces within walls or ceilings, attics, crawl spaces or garages. q For optimal venting installation, we recommend: using roof or wall caps that have back draft dampers using a rigid metal vent q using the most direct route by minimizing the length of the vent and number of elbows to provide efficient performance q using uniformly sized vents q using duct tape to seal all joints in the vent system q using caulking compound to seal exterior wall or roof opening around cap q not installing 2 elbows together, for optimal hood performance If venting through the wall, be sure that there is proper clearance within the wall for the damper to open fully. If venting through the roof, and rectangular to round transition is used, be sure there is at least 3" (7. 6 cm) of clearance between the top of the microwave oven and the transition piece. q q 17 " (43. 8 cm) 16 " (41. 3 cm) 1 (40 5 " . +/- 0 cm) (1. 0 3/8" cm ) " (76. 0 cm) CABINET OPENING DIMENSIONS The grounded 3-prong outlet must be inside the upper cabinet. A B 30" (76. 2 cm) min. upper cabinet and side cabinet depth Roof venting Roof cap 66" (167. 6 cm) min. Wall venting Wall cap A. Grounded 3-prong outlet *30" (76. 2 cm) is typical for 66" (167. 6 cm) installation height. Vent extensio 6" (15. 2 cm) vent system = 73 ft (22. 2 m) total A 6 ft (1. 8 m) B A. 3 " x 10" to 6" (8. 3 x 25. 4 cm to 15. 2 cm) rectangular to round transition piece F. Vent extension piece, at least 3" (7. 6 cm) h 2 ft (0. 6 m) A. 2 ft (0. 6 m) + 6 ft (1. 8 m) straight = 8 ft (2. 4 m) C D 3 " x 10" (8. 3 x 25. 4 cm) vent system = 73 ft (22. 2 m) total A 6 ft (1. 8 m) B 2 ft (0. 6 m) C A. One 3 " x 10" (8. 3 x 25. 4 cm) 90° elbow = 25 ft (7. 6 m) B. [. . . ] One 3 " x 10" (8. 3 x 25. 4 cm) 90° elbow = 25 ft (7. 6 m) B. 2 ft (0. 6 m) + 6 ft (1. 8 m) straight = 8 ft (2. 4 m) If the existing vent is round, a rectangular to round transition piece must be used. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WMH32519CS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WMH32519CS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.