User manual WHIRLPOOL MGC 3010 AAS INSTRUCTION FOR USE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL MGC 3010 AAS. We hope that this WHIRLPOOL MGC 3010 AAS user guide will be useful to you.


WHIRLPOOL MGC 3010 AAS INSTRUCTION FOR USE: Download the complete user guide (174 Ko)

You may also download the following manuals related to this product:

   WHIRLPOOL MGC 3010 AAS PROGRAM CHART (916 ko)

Manual abstract: user guide WHIRLPOOL MGC 3010 AASINSTRUCTION FOR USE

Detailed instructions for use are in the User's Guide.

[. . . ] Keep the packaging material (plastic bags, polystyrene parts, etc. ) out of the reach of children, as they are potentially dangerous. Check whether the hob has been damaged during transport and remove any protective film from the appliance parts. Any other use (such as heating rooms) is to be considered improper and, as a consequence, dangerous. Ensure that the installation and gas/electrical connections are performed by a qualified technician in compliance with current local safety regulations. [. . . ] This room must also be continuously ventilated, fresh air should flow through permanent openings in walls to outside or to an adjacent non-inhabitable room as detailed is AS 5601. These permanent openings must be made in such a way that it cannot be obstructed from either side of the wall, also they should be protected by plastic grids, metallic mesh, etc. , taking care not to reduce the air vent effective area mentioned above and located near floor level and positioned so as not to interfere with the operation of the exhaust system, the minimum cross section of these permanent openings is set by AS5601. • - OVERHEAD CLEARANCE Range hoods and exhaust fans shall be installed in accordance with the manufactures instructions. However, in no case shall the clearance between the top of the highest burner of the cooking appliance and the range hood be less than 600mm or, for an overhead exhaust fan, 750mm Any downward facing combustible surface less than 600mm above the top of the highest burner shall be protected for the full width and depth of the cooking surface area in accordance with Clauses 5. 12. 1. 2 of AS 5601 However, in no case shall this clearance to any surface be less than 450mm. SIDE CLEARANCE Where the distance measured between the periphery of the burner and any vertical combustible surface is less than 200mm, the surface shall be protected in accordance with Clause 5. 12. 1. 2 of AS5601 to a height of not less than 150mm above the hotplate top surface for the full length and width of the cooking surface area. Note: the cooking surface area is defined as the part of the appliance where the cooking normally takes place and does not include those parts of the appliance containing the control knobs. INSTALLATION GAS CONNECTION 1. 5. ELECTRICAL CONNECTION • • • The electrical connections must comply with local regulations. The data relevant to the voltage and power absorption are indicated on the rating plate. The earthing of this appliance is compulsory by law. L Earth (yellow/green) N 6. 10. Check the “gas type” sticker attached to the hotplate. Details of the injector sizes used are recorded on the data plate located on the base of the appliance. This appliance shall be installed in accordance with installation requirements of the local gas authority to the appropriate installation code (AS5601). Before installing the hotplate consider the location of the gas supply and routing the gas line. For ULPG models the gas supply for the hotplate must be regulated to a pressure of 2. 75kPa. The gas inlet connection fitting is ½” B. S. P female thread. For NG models the gas supply is connected to a regulator which is supplied. IT IS ESSENTIAL THAT THE ELBOW ON THE APPLIANCE BE HELD FIRMLY WITH A SPANNER. A manual shut-off valve must be installed in the gas line, in an accessible position external to the hotplate, so that in the event of an emergency or service, the gas supply can be shutoff. After installing the gas supply and making all connections check thoroughly for possible leaks. Using a soap and water solution check each gas connection one at a time, by brushing the solution over connection. If burners shows any abnormalties check the following: Burner cap on correctly Burner positioned correctly Burner vertically aligned with injector nipple In some cases the burners will fail to ignite immediately and will seem to 'blow's lightly when they do ignite, this is usually due to air in the gas pipe which should clear itself within seconds of operation. If after following the instructions given, satisfactory performance cannot be obtained, contact the local gas authority for advice and assistance. WIRING DIAGRAM 00 11 22 33 44 55 66 77 88 99 09 29 49 69 90 45 BLACK BROWN RED ORANGE YELLOW GREEN BLUE VIOLET BLUE SKY WHITE WHITE-BLACK WHITE-RED WHITE-YELLOW WHITE-BLUE GREY YELLOW-GREEN N6 : SPARK IGNITION SWITCH (UNDER KNOB) Q : SPARK IGNITION PLUG W/PI: MAINS TERMINAL BLOCK/SPARK IGNITION X2 : COOKTOP EARTHING 230 - 240 V • • • The manufacturer cannot be held responsible for any injury to persons or animals or damage to property arising from failure to comply with these requirements. When the hob is installed, provide a single-pole circuit breaker with a contact separation of at least 3 mm. If necessary, the electrical power cable must be replaced exclusively with a power cable having identical characteristics to the original supplied by the manufacturer (type H05V2V2-F T90°C or H05RR-F). [. . . ] Note: Failure to comply with these instructions may compromise the safety and quality of the product. Customer Service: 1300 363 344 Service Call Booking: 1300 361 166 CARE AND MAINTENANCE CLEANING THE HOB SURFACE • • To maintain your hob in perfect conditions, clean it after every use, removing any food spills. Before any cleaning operation, disconnect the hob from the mains and wait for it to cool down. • • All the enamelled and glass parts should be cleaned with warm water and neutral solution. Stainless steel surfaces may be stained by calcareous water or aggressive detergents if left in contact for too long. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL MGC 3010 AAS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL MGC 3010 AAS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.