User manual WHIRLPOOL AMD 030 - 034

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL AMD 030 - 034. We hope that this WHIRLPOOL AMD 030 - 034 user guide will be useful to you.


WHIRLPOOL AMD 030 - 034 : Download the complete user guide (4064 Ko)

Manual abstract: user guide WHIRLPOOL AMD 030 - 034

Detailed instructions for use are in the User's Guide.

[. . . ] а употреба Návod k použití Návod na použitie Instruc∑iuni de utilizare Инструкции по эксплуатации 501932602028:Layout 1 1-12-2008 16:58 Pagina 2 501932602028:Layout 1 1-12-2008 16:58 Pagina 3 ENGLISH РУCCКИЙ Instructions for use Инcтpyкции по экcплyaтaции Page 4 Cтpaницa 27 3 501932602028:Layout 1 1-12-2008 16:58 Pagina 4 AMD 030 - 031 - 032 - 033 - 034 INSTRUCTIONS FOR USE BEFORE USING THE APPLIANCE SAFETY PRECAUTIONS AIR CONDITIONER PRECAUTIONS SAFEGUARDING THE ENVIRONMENT PRODUCT DESCRIPTION CONTROL PANEL DISPLAY INDICATORS DESCRIPTION REMOTE CONTROL FUNCTIONS AND INDICATORS INDICATOR SYMBOLS ON RC DISPLAY STORAGE AND TIPS FOR USING THE RC OPERATING MODE DESCRIPTION AIRFLOW DIRECTION CONTROL MODE AND FUNCTION DESCRIPTIONS MAINTENANCE PROTECTION TROUBLESHOOTING INSTALLATION INSTRUCTIONS INDOOR UNIT INSTALLATION WIRING DIAGRAM OUTDOOR UNIT INSTALLATION 4 Page 5 5 6 6 7 8 9 9 10 11 12 13 16 16 17 18 20 23 25 501932602028:Layout 1 1-12-2008 16:58 Pagina 5 BEFORE USING THE APPLIANCE To make the most out of your new appliance, please read the user instructions carefully and keep them handy for future consultation. Before using the appliance please follow and set according to the below indications: Remote Control (RC) presetting: Each time the batteries are replaced in the remote control, the RC is pre-set on Heat pump. If the air conditioner that you purchased is a cooling only, then the pre-set on Heat pump will not bring any changes. Auto-Restart presetting Function: To set the auto-restart function, press the Emergency button (ON/OFF) on the indoor unit for at least 5 seconds A buzz sound will signal that the auto-restart function is set and the air conditioner is in standby. [. . . ] Unplug from the power supply Turn off the appliance first before disconnecting from power supply. Use lukewarm water (below 40°C) to clean if the appliance is very dirty. Never use substances such as gasoline or polishing powder to clean the appliance. Air filter It is necessary to clean the air filter after using it for about 100 hours. Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment. Unplug from the power supply Turn off the appliance first before disconnecting from power supply and remove the air filter. If the filter is very dirty, clean it with a solution of lukewarm water and neutral detergent. B PROTECTION Operating condition The protective device maybe trip and stop the appliance in the cases listed below. Outdoor air temperature is over 24°C HEATING Outdoor air temperature is below -7°C Room temperature is over 27°C Outdoor air temperature is over *43°C COOLING Room temperature is below 21°C DRY Room temperature is below 18°C *For Tropical (T3) Climate condition models, the temperature point is 52°C instead of 43°C. If the air conditioner runs in COOLING or DRY mode with door or window opened for a long time when relative humidity is above 80%, dew may drip down from the outlet. Noise pollution • Install the air conditioner at a place that can bear its weight in order to operate more quietly. 16 501932602028:Layout 1 1-12-2008 17:02 Pagina 17 • Install the outdoor unit at a place where the air discharged and the operation noise would not annoy your neighbours. € Do not place any obstacles in front of the air outlet of the outdoor unit lest it increases the noise level. Protection device Wait at least 3 minutes before restarting the unit after operation stops or changing mode during operation. After connecting to power supply and turning on the appliance immediately, a delay of 20 seconds may occur before it starts to operate. Features of HEATING mode Preheating 2-5 minutes are necessary to preheat the indoor unit at HEATING operation start. Defrosting (out door unit) In HEATING operation the appliance will defrost (de-ice) automatically to raise efficiency. after defrosting completes , it returns to HEATING mode automatically. Note: Heating is NOT available for cooling only air conditioner models. tROUBLESHOOTING Trouble Analysis • Is the protection device or fuse blown?€ Please wait for 3 minutes and start again, protection device may be preventing unit to work. € Has there been a strong interference (from excessive static electricity discharge, power supply voltage abnormality)? [. . . ] In order not to disturb your neighbours and protect the environment, install a drain port and a drain hose to direct the condensate water. Just install the drain port and rubber washer on the chassis of the outdoor unit, then connect a drain hose to the port Washer as shown in the figure on the right . Install and Fix Outdoor Unit Drain hose Fix with bolts and nuts tightly on a flat and strong (prepare by user) floor. If installed on the wall or roof, make sure to fix the supporter well to prevent it from shaking due to serious vibration or strong wind. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AMD 030 - 034




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL AMD 030 - 034 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.