User manual TEXECOM PREMIER 832
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEXECOM PREMIER 832. We hope that this TEXECOM PREMIER 832 user guide will be useful to you.
You may also download the following manuals related to this product:
TEXECOM PREMIER 832 BROCHURE (220 ko)
Manual abstract: user guide TEXECOM PREMIER 832
Detailed instructions for use are in the User's Guide.
[. . . ] THANK YOU FOR VOTING TEXECOM
MASTER USER MANUAL
Security Control Panels with Integrated Communicator
INS141-7
Contents
Premier 412/816/832 Master User Manual
Contents
1. 3
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 About this Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Fire Detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The selected partition(s) is now Away armed.
"
8
If the Quick Arm feature is enabled, you can omit step 1 from the above procedure. INS141
Premier 412/816/832 Master User Manual
Operating the Alarm System " To manually bypass zones, proceed as follows:
Changing to another Partition
Normally the remote keypad that you use will be assigned to a particular partition and therefore the zone and status lights will indicate information relevant to the assigned partition. However, you can temporarily switch the remote keypad to a different partition so that the zone and status lights indicate the information relevant to the partition that you have selected. Whilst in this mode you can also use your Access code to arm/disarm the partition you have selected (providing you have access to the selected partition). In order to use the cross partitioning feature, it is recommend that the system is configured as follows: · · · · Cross partitioning must be enabled. The user should be set for "Local Partition Access Only", see page 18. The remote keypads should only be assigned to a single partition.
1
1 2 3
Enter Access code ????
4
Zones
5
6
7
8
Alarm Service
Armed Ready
YES to Arm?MENU for Options Bypass Zone> 00 *NONE BYPASSED*
2
1 2 3 4
Press B
Zones
5 6 7 8
Alarm Service
Armed Ready
3
1 2 3
The Ready light will flash quickly. Enter 02 to select Zone 2.
4
Zones
5
6
7
8
Alarm Service
Armed Ready
Bypass Zone> 02 Zone 02 Bypassed
4 5
The selected zone is now bypassed. Once the selected zones have been bypassed press: y/a to Away arm s to Stay arm N to return to the normal disarmed state
" To change to another partition, proceed as follows:
1
1 2 3 4
Press A
Zones
5 6 7 8
"
If the Quick Bypass feature is enabled, you can omit step 1 from the above procedure. When one or more zones are bypassed the Ready light will flash and if the system is fitted with a Premier RKP8/16 Plus or LCD remote keypad then the Bypass light will also illuminate.
Alarm Service
Armed Ready
AREA ARMED >. . . . Press 2 to select Partition 2.
4
Zones
5
6
7
8
Alarm Service
Armed Ready
Premier 816 17:35. 38 28/04
Unbypassing Zones
To manually unbypass zones, perform the manual Bypass procedure on a zone that is already bypassed. · 24 hour zones cannot be unbypassed if they are still violated. If your installer has enabled the "Reinstate Bypassed Zones on Disarm" option, all zones will automatically be unbypassed each time the system is disarmed.
The remote keypad will now indicate information relevant to the selected partition.
"
After changing to the selected partition, the remote keypad will only remain in the selected partition for 10 seconds after the last key press. However if an Access code is entered whilst the remote is in this mode, the remote keypad will remain in the selected partition for 1 minute after the last key press.
·
Bypassing Zones
Manually Bypassing Zones
Bypassing a zone prevents it from causing an alarm.
"
After manually bypassing a zone, the zone will remain bypassed until the zone is manually unbypassed. The Bypass menu will time-out if no key is pressed for 60 seconds.
INS141
9
Operating the Alarm System
Premier 412/816/832 Master User Manual " To Quick Bypass a group of zones and Away arm, proceed as follows:
Group Bypass
The Group Bypass feature allows you to bypass a predefined group of zones. " To bypass a group of zones, proceed as follows:
1
1 2 3 4
Enter bypass group 1 - 4
Zones
5 6 7 8
Alarm Service
Armed Ready
Premier 816 19:30. 56 28/04
1
1 2 3
Enter Access code ????
4
2
1
Press a
2 3 4
Press y
8
Zones
5
6
7
Zones
5
6
7
8
Alarm Service
Armed Ready
YES to Arm?MENU for Options Bypass Zone> 00 Zone 03 Bypassed Bypass Zone> 00 Zone 04 Bypassed
Alarm Service
Armed Ready
Please Exit. . . . 19:30. 56 28/04
2
Alarm Service
Enter bypass group 1 - 4 followed by B
1 2 3 4
The Armed and Ready lights will flash and the exit tone will sound.
Zones
5
6
7
8
Armed Ready
3
When the exit tone stops, the system is Away armed with the selected group of zones bypassed.
3
The keypad will display the bypassed zones. If required, zones can be added or removed from the group by entering the required zone number ??, e. g. Enter 05 to add Zone 5.
1 2 3 4
" To Quick Bypass a group of zones and Stay arm, proceed as follows:
Zones
5
6
7
8
Alarm Service
Armed Ready
Bypass Zone> 05 Zone 03 Bypassed Bypass Zone> 05 Zone 04 Bypassed Bypass Zone> 05 Zone 05 Bypassed
1
1 2 3 4
Enter bypass group 1 - 4
Zones
5 6 7 8
Alarm Service
Armed Ready
Premier 816 19:30. 56 28/04 Premier 816 19:30. 56 28/04
2
1 2 3 4
Press s
Zones
5 6 7 8
4 5
Alarm
Armed Ready
The selected zone is now bypassed. Once the selected zones have been bypassed press: y/a to Away arm s to Stay arm N to return to the normal disarmed state
Service
The alarm system will arm immediately and the Armed and Ready lights will flash.
3
The system is Stay armed with the selected group of zones bypassed.
"
If the Quick Bypass feature is enabled, you can omit step 1 from the above procedure. [. . . ] Revise the plan as conditions change, such as the number of people in the home, or if there are changes to the building's construction.
3.
·
3.
"
·
·
·
Household Fire Safety Audit
Most fires occur in the home. To minimise the risk of fire, it is recommended that a household safety audit is conducted and a fire escape plan is developed. · Are all electrical appliances and outlets in a safe condition?If you are uncertain about the condition of your electrical appliances or household service, have a professional evaluate these units. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TEXECOM PREMIER 832
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEXECOM PREMIER 832 will begin.