User manual SIEMENS HB65LR560F/35 INSTALLATION INSTRUCTIONS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SIEMENS HB65LR560F/35. We hope that this SIEMENS HB65LR560F/35 user guide will be useful to you.


SIEMENS HB65LR560F/35 INSTALLATION INSTRUCTIONS: Download the complete user guide (1041 Ko)

You may also download the following manuals related to this product:

   SIEMENS HB65LR560F/35 (2790 ko)
   SIEMENS HB65LR560F/35 SUPPLEMENT (789 ko)

Manual abstract: user guide SIEMENS HB65LR560F/35INSTALLATION INSTRUCTIONS

Detailed instructions for use are in the User's Guide.

[. . . ] J Fitted units must be heatĆresistant up to 90 ºC, and neighbouring unit fronts up to 70 ºC. J Cut out the units and the work surface before fitting the appliances. [. . . ] Remove any shavings or the function of the electrical components may be impaired. J The power socket for the appliance must either be located in the hatched area B or else away from the installation space. J A gap of 5 mm is required between the appliance and surrounding unit fronts. There must be a ventilation cutĆout made in the intermediate floor of the surround unit. If a fitted oven is to be built in under a hob, pay attention to the hob installation instructions. Eckeinbau Ć Bild 3 The appliance may also be installed in a tall unit. Câble de raccordement avec fiche avec terre Power cable without a plug with earthing contact Only allow a licensed professional to connect the appliance. An allĆpole isolating switch with at least a 3 mm contact gap must be available for the installation. Connect the wires of the mains power cable according to the colour coding: Green/yellow earth conductor $ Blue neutral conductor Brown phase (external conductor) L'appareil doit être raccordé impérativeĆ ment à une prise avec terre installée de manière réglementaire. Only in Sweden, Finland and Norway The appliance can also be connected using the plug provided which has an earthing contact system. If this is not the case, an allĆpole isolating switch must be used on the installation side with a contact gap of at least 3 mm. 2+4 GB et Australie uniquement Securing the appliance Ć Figure 5 J If necessary, fit the spacer. [. . . ] If this is not the case, an allĆpole isolating switch must be used on the installation side with a contact gap of at least 3 mm. 2+4 GB et Australie uniquement Securing the appliance Ć Figure 5 J If necessary, fit the spacer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIEMENS HB65LR560F/35




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SIEMENS HB65LR560F/35 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.