User manual SHARP XE-A217B BASIC

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP XE-A217B. We hope that this SHARP XE-A217B user guide will be useful to you.


SHARP XE-A217B BASIC: Download the complete user guide (3385 Ko)

You may also download the following manuals related to this product:

   SHARP XE-A217B (24435 ko)
   SHARP XE-A217B (4263 ko)
   SHARP XE-A217B (24435 ko)
   SHARP XE-A217B (24435 ko)
   SHARP XE-A217B BASIC (4332 ko)
   SHARP XE-A217B BASIC (4288 ko)
   SHARP XE-A217B FULL DETAILED (23854 ko)

Manual abstract: user guide SHARP XE-A217BBASIC

Detailed instructions for use are in the User's Guide.

[. . . ] · Install the register in a location not subject to direct sunlight, unusual temperature changes, high humidity or splashing water. Installation in such locations could cause damage to the cabinet and the electronic components. The water could seep into the interior of the register and cause component failure. The use of such chemicals will lead to discoloration or deterioration of the cabinet. [. . . ] B) For department 17 to 32, enter the unit price, press the d key and press the department key. If you use the programmed unit price, press the d key and press the department key. 8 digits) Department key Correction Correction of Entered Number Correction of the Last Entry When you enter an incorrect number, delete it by pressing the L key immediately after the entry. If you make a mistake when making a department entry, PLU entry, percentage (0) and discount (J), you can correct this entry by pressing the ~ key immediately. Correction of Earlier Entries d C) For department 33 and above, enter the department code using the numeric keys and press the d key, then enter the unit price and press the A key. If you use the programmed unit price, enter the department code and press the d key. code (1 to 99) You can correct any incorrect entry made during a transaction if you find it before finalizing the transaction by pressing the A key. Move the cursor to the item to be voided and press the ~ key. Subtotal Void d Unit price (max. 8 digits) A (In case only preset price entry is allowed. ) Key operation example Clerk assignment Item entries Displaying subtotal Amount tendered Finalizing the transaction * !" : indicate department keys. You can void an entry transaction. Once subtotal void is executed, the transaction is aborted and the register issues an receipt. And then press the z key again. 1L 1500 !* 2300 "* For XE-A217W/XE-A217B A) For the department 1 to 6, enter the unit price and press the department key. - When an including-tax subtotal exceeds eight digits: Clear the error message by pressing the L key and then press a media key to finalize the transaction. D The direct PLU entry function is availbale only for XE-A217W/XE-A217B. Reading and Resetting Sales List of All Available Report · Use the reading function (X) when you need to take the reading of sales information entered after the last resetting. · Use the resetting function (Z) when you need to clear the register's memory. Resetting prints all sales information and clears the entire memory except for the GT1 through GT3, reset count, and consecutive number. · X2 and Z2 reports show periodic (monthly) consolidation information. Mode Item General report PLU report by designated range PLU report by associated department Individual clerk report All clerk report Hourly report GLU report * GLU report by clerk* Balance report * Flash report *: For XE-A217W/XE-A217B only OP X/Z X1/Z1 X Z X Z X2/Z2 X Z D · When both sales quantities and sales amounts are zero, printing is skipped. · "X" represents read symbol and "Z" represents reset symbol in the reports. · When printing is performed continuously, the printing may be intermitted for several seconds. After the intermission, the printing will be restarted. Main Functional Overview The register has the following main functions. Item Entries Single item entries Repeat entries Multiplication entries Split-pricing entries Single item cash sale (SICS) entries Special Entries for PLU PLU entries Direct PLU entries (For XE-A217W/XE-A217B only) Display of Subtotals Subtotal Finalization of Transaction Cash or check sale that does not need any tender entry Credit sale Mixed sales and tender entries Computation of VAT (Value Added Tax)/Tax VAT/tax system VAT surcharge system VAT shift entries (For XE-A217W/XE-A217B only) Guest Check (GLU) Guest look up (GLU) system (For XE-A217W/ XE-A217B only) Auxiliary Entries Refund entries Percentage discount Amount discount Non-add code entry Payment Treatment Currency exchange Received-on-account entries Paid-out entries No-sale (exchange) Cashing a check Correction Correction of the last entry (direct void) Correction of the next-to-last or earlier entries (indirect void) Subtotal void Correction of incorrect entries not handled by the direct, indirect or subtotal void function Special Printing Function Copy receipt printing Bill printing Manager Mode Manager sign-on Override entries Other Functions Training mode SD card mode Electronic journal Electronic journal data view function Reports General report Transaction report Department report PLU report Hourly report Clerk report (All/Individual) GLU (For XE-A217W/XE-A217B only) Balance (For XE-A217W/XE-A217B only) Electric Journal (Search) Flash reports Euro change How to take a X1/Z1 or X2/Z2 report [To take an X1 or X2 report:] key. Select the "4 X1/Z1 MODE" or "5 X2/Z2 MODE" by using the key, and press the A key. Select "2 READING" in the X1/Z1 mode or select "1 READING" in the X2/Z2 mode menu window and press in both cases the A key to display the items list. [. . . ] VORSICHT: Die Netzsteckdose muß nahe dem Gerät angebracht und leicht zugänglich sein. ATTENTION: La prise de courant murale devra être installée à proximité de l'équipement et devra être facilement accessible. AVISO: El tomacorriente debe estar instalado cerca del equipo y debe quedar bien accesible. VARNING: Det matande vägguttaget skall placeras nära apparaten och vara lätt åtkomligt. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP XE-A217B




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP XE-A217B will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.