User manual SHARP XE-A206

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP XE-A206. We hope that this SHARP XE-A206 user guide will be useful to you.


SHARP XE-A206 : Download the complete user guide (2239 Ko)

You may also download the following manuals related to this product:

   SHARP XE-A206 QUICK START GUIDE (501 ko)

Manual abstract: user guide SHARP XE-A206

Detailed instructions for use are in the User's Guide.

[. . . ] 16 5:30 PM Page C2 WARNING FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user’s authority to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. [. . . ] 16 5:31 PM Page 35 3 Miscellaneous Key Programming The cash register provides miscellaneous keys such as %, &, -, f, r, R, V, t, C, c and A. While the cash register is pre-programmed so you can use these keys, you must set a currency conversion rate to use V key. % , & f r , R V C , c and A t (Manual tax) * Item %/Item _: Percent rate (0. 00%), tax status (non-taxable), sign (minus), item % and subtotal % entry* (both are allowed), percent rate limitation (100 %) Amount (0. 00), tax status (non-taxable), sign (minus), item _ and subtotal _ entry* (both are allowed), entry digit limit (7 digits) Not necessary to program Entry digit limit (9 digits) Currency conversion rate (0. 0000), currency conversion rate entry method - open or preset (both are enabled) Compulsory entry of amount tender (not compulsory), entry digit limit (8 digits), footer printing (not printed) Entry digit limit (7 digits) Percent/discount calculation is applied to individual department and PLU/subdepartment. * Subtotal %/Subtotal _: Percent/discount calculation is applied to subtotals. Rate for %, & and V To program zero *Rate % & V or A To program another rate *: Rate 0. 9999 (Currency conversion rate) Key operation example Print 10 P 25 0 P 7674 % V A Percent rate Currency conversion rate You must use a decimal point when setting fractional rates. 00%) % & or A To program for another percent key • Percent entries that exceed the upper limit may be overridden in the MGR mode. Key operation example Print 15 s 29 @ P 00 % A Percentage limit Function parameters for %, & and To program “0” for all items *ABCDEFGH @ % & or A To program for another key 36 A206_3 FOR THE MANAGER 09. 16 5:31 PM Page 37 *: Item: A B C D E F G H Tax 4 status Tax 3 status Tax 2 status Tax 1 status +/- sign Item % / Item _ Subtotal % / Subtotal _ Entry digit limit for discount key Selection: Taxable Non-taxable* Taxable Non-taxable* Taxable Non-taxable* Taxable Non-taxable* + (premium) sign - (discount) sign* Allow* Disallow Allow* Disallow Entry: 1 0 1 0 1 0 1 0 0 1 0 1 0 1 0-7 (default: 7) When programming percent keys, always enter 0 for H. Tax status (taxable 1 through 4 / non-taxable) • When taxable is selected, tax is applied to the amount obtained after premium or discount calculation. +/- sign • Programming of the +/- sign assigns the premium or discount function for each key. Entry digit limit (For discount key only) • The entry digit limit is in effect for the REG mode operations but can be overridden in the MGR mode. The entry digit limit is represented by the number of allowable digit for the maximum entry amount for discount key. Key operation example Print 00011006 @ -A Tax status From left, FGH Sign(E) Function parameters for V To program “0” for all items *AB @ V Selection: Allow* Disallow Allow* Disallow A Entry: 0 1 0 1 *: Item: A B Open rate entry Preset rate entry Key operation example Print 00 @ VA From left, AB 37 A206_3 FOR THE MANAGER 09. 16 5:31 PM Page 38 Entry digit limit for r, R and t Entry digit limit @ r, R t or A (only for manual entry) • For r R, enter 0 to 9 (digits), and for t (manual tax), enter 0 to 7 (digits). Entry digit limit is in effect for REG mode operation but can be overridden in MGR mode. The entry digit limit is represented by the number of allowable digits for maximum entry or total amount. When “0” is set, the operation of the corresponding key is prohibited. Key operation example Print 4@ RA Function parameters for C, c and A (when using as CA key) To program “0” for all items *1ABC @ s, C c or *2 A Entry: To program for another key *2:Press s key for CA key setting. [. . . ] error code E01 E02 E03 E07 E11 E12 E32 E34 E35 E36 E37 E67 Registration error Misoperation error Undefined code is entered. Compulsory depression of the s key for direct finalization Compulsory tendering No entry of a clerk code Overflow limitation error The open price entry is inhibited. Finalize the transaction, and correct the wrong entries in the void mode. 12 lines/second 24 digits each for receipt and journal paper • Graphic logo printing function • Logo message function • Receipt (ON-OFF) function, compression printing function Paper roll: Width: 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP XE-A206




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP XE-A206 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.