User manual SHARP UP-600/700

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP UP-600/700. We hope that this SHARP UP-600/700 user guide will be useful to you.


SHARP UP-600/700 : Download the complete user guide (1080 Ko)

Manual abstract: user guide SHARP UP-600/700

Detailed instructions for use are in the User's Guide.

[. . . ] POS TERMINAL MODEL UP-600 UP-700 INTER-REGISTER COMMUNICATION SYSTEM INSTRUCTION MANUAL TABLE OF CONTENTS Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Inline Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Message display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 (1) The message displayed during inline communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 19 (2) List of consolidated reports (SYSTEM READING/RESETTING) Operating modes Report type DEPARTMENT Description Full department report Individual dept. group total report Department markdown report PLU/UPC report by specified range PLU/UPC pick up report PLU/UPC report by associated dept. Individual PLU/UPC specified report PLU/UPC group total report PLU/UPC stock total report PLU/UPC stock pick up report PLU/UPC zero sales report PLU/UPC zero sales report by specified dept. STOCK PLU CATEGORY PLU/UPC minimum stock report PLU/UPC sales report by price category Dynamic UPC by designated range Dynamic UPC pick up report OP XZ X1/Z1 X1, Z1 X2, Z2 X1 X2 X1 X2 X1 X2 X1, Z1 X2, Z2 X1, Z1 X2, Z2 X1, Z1 X2, Z2 X1 X2 X1 X2 X1 X1 X1 X2 X1 X2 X1 X1 X2 X1, Z1 X2, Z2 X1, Z1 X2, Z2 X2/Z2 Job # 1110 1210 1112 1212 1113 1213 1119 1219 1120 PLU/UPC code (To specify a PLU/UPC range, enter 1220 start and end PLU/UPC codes. ) 1120 1220 1121 1221 1122 1222 1123 1223 1124 1124 1127 1227 1127 1227 1128 1129 1229 1169 1269 1169 1269 *1 Start/end UPC codes Price PLUs of zero sales by department PLU/UPC code *1 All PLUs of zero sales. TOTAL M-DOWN DEPT. PLU/UPC PLU PICK UP PLU BY DEPT PLU IND. TOTAL PLU STOCK PLU STOCK PICK PLU ZERO SALES DYNAMIC UPC D-UPC PICK UP 20 Operating modes Report type D-UPC BY DEPT Description Dynamic UPC by associated dept. Transaction report OP XZ X1/Z1 X1, Z1 X2, Z2 X1, Z1 X2, Z2 CID Cash-in-drawer report Tax report X1 X2 X1 X2 POSITIVE CHECK ALL SERVER Positive no. SERVER Individual server report OP XZ X1, Z1 X2, Z2 HOURLY Hourly report X1 X2/Z2 Job # 1166 1266 1130 1230 1131 1231 1133 1233 1139 1140 1240 1041 1141 1241 1160 Use the military time (24-hour) system. For example, to set 2:30 a. m. , enter 230; and to set 2:30 p. m. , enter 1430. For all 48 half-hours with zero skipped For all servers Required data/Remarks Department code TRANSACTION TAX X1, Z1 DAILY NET GLU Daily net report GLU report X1, Z1 X2, Z2 1160 1270 1180 GLU/PBLU code. (The range can be specified by entering start and end codes. ) GLU BY SERVER CLOSED GLU GLU report by server Closed GLU report X1, Z1 X1, Z1 1181 1182 Bill no. (The range can be specified by entering start and end codes. ) CL-GLU BY SERVER CUSTOMER SALES 1 Closed GLU report by server Customer sales report 1 (Only details) Customer sales report 2 (Detail/amount & total) X1, Z1 X2, Z2 1183 1285 Customer code (The range can be specified by entering start and end codes. ) Customer code (The range can be specified by entering start and end codes. ) CUSTOMER SALES 2 X2, Z2 1289 21 Operating modes Report type CUSTOM BY AMT Description Customer sales report (by the specified sales range) Customer charge account Non-accessed UPC report Non-accessed UPC report (Delete) NO ACCESS CUSTOM Non-accessed customer report Non-accessed customer report (Delete) CUSTOMER DELETE STACKED REPORT Customer delete report Stacked report (X1/Z1) Stacked report (X2/Z2) X1, Z1 X1 Z1 OP XZ X1/Z1 X2/Z2 X2 Job # 1286 Required data/Remarks Customer sales range CHARGE ACCOUNT NO ACCESS UPC X2 1288 1105 1105 X2 Z2 1287 1287 Z2 1298 1190 1191 Stacked report 1 Stacked report 2 Stacked report 1 Stacked report 2 STACKED REPORT X2, Z2 1290 1291 NOTE 1: You can pick up PLU/UPC codes for issuing the report. You can pick up new PLU/ UPC codes or the codes that were picked up the last time. To pick up new codes, select "1 NEW PICK UP", and follow the procedure show below to pick up new codes. To pick up the codes that were picked up last time, select "2 LAST PICK UP". Follow the following procedure for picking up PLU/UPC codes. To pick up another code PLU/UPC code (PLU code: max. 13digits) @ FOR CA/AT Scanning UPC code @ FOR CA/AT To pick up PLU/UPC codes that were picked up the last time To pick up all PLU/UPC codes CA/AT 22 4. Individual reports -- master/back-up master/satellite (1) Report generation procedure To generate respective reports, use the following procedure, referring to the list of individual reports on the following pages. 1. Turn the mode switch to the required position (OPXZ, X1/Z1 or X2/Z2). 2. Select "READING" or "RESETTING" depending on your need, and press the [ENTER] key. 3. Select the type of report you wish to generate and press the [ENTER] key or enter the corresponding report type No. (If the desired type of report is not listed on the display, scroll up or down the screen. ) 4. [. . . ] · The above-mentioned data clearing jobs should be performed at the advice of your authorized SHARP dealer. 54 (2) Data clearing of the capture data -- master and satellite Clearing procedure After selecting "DATA CLEAR" from the PGM2 mode menu with the same procedure as steps 1 and 2 in "(1) Data clearing of the T-LOG buffer, " select "CAPTURE DATA". (3) Data clearing of the transaction memory -- master and satellite You can clear the transaction memory in the event there is some trouble and the terminal's memory requires clearing. Clearing procedure After selecting "DATA CLEAR" from the PGM2 mode menu with the same procedure as steps 1 and 2 in "(1) Data clearing of the T-LOG buffer, " select "TRANSACTION. " (4) Data clearing of the hourly sales data memory -- master and satellite You can clear the hourly sales data memory in the event there is some trouble and the terminal's memory requires clearing. Clearing procedure After selecting "DATA CLEAR" from the PGM2 mode menu with the same procedure as steps 1 and 2 in "(1) Data clearing of the T-LOG buffer, " select "HOURLY. " (5) Data clearing of the daily net sales data memory -- master and satellite You can clear the daily net sales data memory in the event there is some trouble and the terminal's memory requires clearing. Clearing procedure After selecting "DATA CLEAR" from the PGM2 mode menu with the same procedure as steps 1 and 2 in "(1) Data clearing of the T-LOG buffer, " select "DAILY NET. " 55 (6) Data clearing of the server sign-on state -- master You can clear the master's server sign-on status flags in case of trouble. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP UP-600/700




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP UP-600/700 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.