User manual SHARP AY-XP9FR-N

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP AY-XP9FR-N. We hope that this SHARP AY-XP9FR-N user guide will be useful to you.


SHARP AY-XP9FR-N : Download the complete user guide (1117 Ko)

You may also download the following manuals related to this product:

   SHARP AY-XP9FR-N (1113 ko)

Manual abstract: user guide SHARP AY-XP9FR-N

Detailed instructions for use are in the User's Guide.

[. . . ] AY-XP9FR -N AY-XP12FR-N AY-XP12GR-N SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL INDOOR UNIT OUTDOOR UNIT AY- XP9FR-N AE- X9FR-N AY- XP12FR-N AE- X12FR-N AY- XP12GR-N AE- X12GR-N *Plasmacluster is a trademark of SHARP Corporation. A. In the European Union Attention: If you want to dispose of this equipment, please do not use the ordinary dust bin!Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper treatment, recovery and recycling of used electrical and electronic equipment. Following the implementation by member states, private households within the EU states may return their used electrical and electronic equipment to designated collection facilities free of charge*. [. . . ] · The unit can be affected by signals transmitted from the remote control of a television, VCR or other equipment used in the same room. · Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit and remote control from moisture and shock which can discolour or damage them. SET CURRENT CLOCK TIME There are two clock modes: 12-hour mode and 24-hour mode. Example: 5 o'clock in the afternoon Clock Display 12-hour mode 24-hour mode PM 5:00 17:00 MODE 1h 1 To set to the 12-hour mode, press the CLOCK button once in the first step. 2 3 1 To set to the 24-hour mode, press the CLOCK button twice in the first step. TIME 2 Press the set theADVANCE or REVERSE button to current time. · Keep the button pressed to advance or reverse the time display quickly. CLEAN FAN SWING SET/C the SET/C button. 3 Press colon (:) blinks to indicate that the · The clock is functioning. NOTE: · The current time cannot be set when the timer is operating. 7 BASIC OPERATION 1 Press the MODE button to select the operation mode. AUTO HEAT COOL DRY 2 2 5 3 DISPLAY Press the ON/OFF button to start operation. · The red OPERATION lamp ( will light. · During SELF CLEAN operation, the indicator panel will display remaining time of the operation. Room and outdoor temperature will not be displayed even if you press the DISPLAY button. 9 ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION 1 Press the SWING button remote control once. MODE 1h on the · The vertical adjustment louvres will change its angle continuously. CLEAN FAN SWING SET/C 1 2 again when 2 Press the SWING button louvres are the vertical adjustment at the desired position. · The louvre will stop moving within the range shown in the diagram. · The adjusted position will be memorized and will be automatically set to the same position when operated the next time. Adjustment range COOL and DRY modes HEAT mode HORIZONTAL AIR FLOW DIRECTION Hold the horizontal adjustment louvre as shown in the diagram and adjust the air flow direction. AY-XP9FR-N/AY-XP12FR-N AY-XP12GR-N CAUTION Never attempt to adjust the vertical adjustment louvres manually. · Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction when the remote control is used for adjustment. · When the vertical adjustment louvre is positioned at the lowest position in the COOL or DRY mode for an extended period of time, condensation may result. Do not adjust the horizontal adjustment louvre to the extreme left or right in the COOL mode with the fan speed set to "SOFT ( )" for an extended period of time. Condensation may form on the louvres. 10 PROGRESSIVE AIRFLOW Press the PROGRESSIVE AIRFLOW button during cooling or dry operation when you do not want to feel cold air. Vertical adjustment louvres are set obliquely upward to deliver cool air to the ceiling. Vertical adjustment louvres are set downward to deliver the warm air down to the floor and warm you. 1 During operation, AIRFLOW button. AM press the PROGRESSIVE . · The remote control will display TO CANCEL Press the PROGRESSIVE AIRFLOW button. NOTES: DISPLAY 1 · The PROGRESSIVE AIRFLOW setting is cancelled when you press FULL POWER button while PROGRESSIVE AIRFLOW is set. · If you want PROGRESSIVE AIRFLOW operation in FULL POWER mode, press PROGRESSIVE AIRFLOW button during FULL POWER operation. FULL POWER OPERATION In this operation, the air conditioner works at maximum power to makes the room cool or warm so rapidly that you can use it just after you come home. FULL 1 To activate the button POWER operation, press the FULL POWER during operation. · The remote control will display . · The green FULL POWER lamp ( ) on the unit will light up. AM TO CANCEL Press the FULL POWER button again. DISPLAY 1 NOTE: · FULL POWER operation will also be cancelled when the operation mode is changed, or when the unit is turned off. · The green FULL POWER lamp ( ) on the unit will turn off. · You can not set the temperature or fan speed during the FULL POWER operation. 11 PLASMACLUSTER OPERATION The Plasmacluster Ion generator inside the air conditioner will release positive and negative plasmacluster ions into the room. Approximately the same numbers of positive and negative ions released into the air will reduce some airborne mold. 1 During operation, press the PLASMACLUSTER button. · The remote control will display " " · The blue PLASMACLUSTER lamp on the unit will light up. TO CANCEL 1 DISPLAY Press the PLASMACLUSTER button again. · The PLASMACLUSTER lamp on the unit will turn off. NOTES: · Use of the PLASMACLUSTER operation will be memorized, and it will be activated the next time you turn on the air conditioner. · To turn off the PLASMACLUSTER lamp, press the DISPLAY button. · When the PLASMACLUSTER button is pressed while the unit is not operating, the PLASMACLUSTER operation will be performed without accompanying air conditioning mode (eg, HEATING or COOLING). [. . . ] Clean the filters, then reinstall them. 1 Make sure that the air filters are not dirty. rack 3 Check the outdoor mountingmake periodically for wear and to sure it is firmly in place. CHANGING THE DEODORANT DUST COLLECTION FILTER The filter should be changed every 3 ~ 6 months Filter stopper 1 REMOVE THE AIR FILTER 2 CHANGE THE DEODORANT COLLECTION FILTER DUST 1 Take off the old deodorant dust collection filter from the air filter. 2 Set the new deodorant dust collection filter, under the filter stoppers located on the air filter. 3 REINSTALL THE AIR FILTER NOTE: · The dirty deodorant dust collection filter is not washable for reuse. The new filter is available at your nearest dealer. Replacement filter: Type AZ-F920FN Disposal of Filters Please dispose of replaced filters according to the local disposal laws and regulations. DEODORANT DUST COLLECTION Filter materials: · Filter: Polypropylene · Frame: Polyester 17 ADDITIONAL NOTES ON OPERATION OPERATING TEMPERATURE RANGE INDOOR TEMP. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AY-XP9FR-N




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AY-XP9FR-N will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.