User manual SHARP AY-XP12DR-NC

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP AY-XP12DR-NC. We hope that this SHARP AY-XP12DR-NC user guide will be useful to you.


SHARP AY-XP12DR-NC : Download the complete user guide (1006 Ko)

Manual abstract: user guide SHARP AY-XP12DR-NC

Detailed instructions for use are in the User's Guide.

[. . . ] AY-XP12DR-NC SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL · Uses ozone layer friendly refrigerant R410A. INDOOR UNIT OUTDOOR UNIT AY-XP12DR-NC AE-X12DR-N *Plasmacluster is a trademark of SHARP Corporation. A. In the European Union Attention: If you want to dispose of this equipment, please do not use the ordinary dust bin!Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper treatment, recovery and recycling of used electrical and electronic equipment. Following the implementation by member states, private households within the EU states may return their used electrical and electronic equipment to designated collection facilities free of charge*. [. . . ] Also, protect the unit and remote control from moisture and shock which can discolour or damage them. SET CURRENT CLOCK TIME There are two clock modes: 12-hour mode and 24-hour mode. Example: 5 o'clock in the afternoon Clock Display 12-hour mode 24-hour mode PM 5:00 17:00 MODE 1h 1 To set to the 12-hour mode, press the CLOCK button once in the first step. 2 3 1 To set to the 24-hour mode, press the CLOCK button twice in the first step. TIME 2 Press the set theADVANCE or REVERSE button to current time. · Keep the button pressed to advance or reverse the time display quickly. CLEAN FAN SWING SET/C 3 Press the SET/C button. · Only the room temperature can be displayed for 5 seconds when the unit is not in operation. · During SELF CLEAN operation, the indicator panel will display remaining time of the operation. Room and outdoor temperature will not be displayed even if you press the DISPLAY button. PROGRESSIVE AIRFLOW Press the PROGRESSIVE AIRFLOW button during cooling or dry operation when you do not want to feel cold air. Vertical adjustment louvre is set obliquely upward to deliver cool air to the ceiling. Vertical adjustment louver is set downward to deliver the warm air down to the floor and warm you. 1 During operation, AIRFLOW button. AM press the PROGRESSIVE . · The remote control will display TO CANCEL Press the PROGRESSIVE AIRFLOW button. NOTES: DISPLAY 1 · The Progressive Airflow setting is cancelled when you press FULL POWER button while Progressive Airflow is set. · If you want Progressive Airflow operation in Full Power mode, press PROGRESSIVE AIRFLOW button during Full Power operation. E-9 ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION The air flow direction is automatically preset in each mode as follows for optimum comfort: COOL and DRY modes HEAT mode Horizontal air flow Diagonal air flow HOW TO ADJUST THE AIR FLOW DIRECTION Press the SWING button on the remote control once. · The vertical adjustment louvre will change its angle continuously. Adjustment range COOL and DRY modes HEAT mode Press the SWING button again when the vertical adjustment louvre is at the desired position. · The louvre will stop moving within the range shown in the diagram. · The adjusted position will be memorized and will be automatically set to the same position when operated the next time. HORIZONTAL AIR FLOW DIRECTION Hold the horizontal adjustment louvre as shown in the diagram and adjust the air flow direction. CAUTION Never attempt to adjust the vertical adjustment louvres manually. · Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction when the remote control is used for adjustment. · When the vertical adjustment louvre is positioned at the lowest position in the COOL or DRY mode for an extended period of time, condensation may result. Do not adjust the horizontal adjustment louvre to the extreme left or right in the COOL mode with the fan speed set to "SOFT( )" for an extended period of time. Condensation may form on the louvres. E-10 10°C OPERATION Heating operation with 10°C set temperature will be performed. AM 1 Press the MODE button and select HEAT mode. · 10°C operation will also be cancelled when the operation mode is changed, or when the unit is turned off. DISPLAY MODE 1h CLEAN FAN SWING SET/C 1 NOTE: · 10°C operation will not be available with heating operation automatically selected by AUTO mode. FULL POWER OPERATION In this operation, the air conditioner works at maximum power to make the room cool or warm so rapidly that you can use it just after you come home. FULL 1 To activate the button POWER operation, press the FULL POWER during operation. · The remote control will display . · The temperature display will go off. AM TO CANCEL Press the FULL POWER button again. · FULL POWER operation will also be cancelled when the operation mode is changed, or when the unit is turned off. DISPLAY 1 NOTE: · You can not set the temperature or fan speed during the FULL POWER operation. E-11 ONE-HOUR OFF TIMER When the ONE-HOUR OFF TIMER is set, the unit will automatically turn off after one hour. 1 Press the ONE-HOUR OFF TIMER button. · The remote control displays " ". · The orange TIMER lamp ( · The unit will stop operating after one hour. TO CANCEL Press the TIMER CANCEL (SET/C) button. MODE 1h 1 · The orange TIMER lamp ( ) on the unit will turn off. CLEAN FAN Alternatively, turn the unit off by pressing the ON/ OFF button. · The red OPERATION lamp ( ) and the orange TIMER lamp ( ) on the unit will turn off. NOTES: · The ONE-HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF operations. · If the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will operate for an hour at the formerly set condition. · If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER is activated, press the ONE-HOUR OFF TIMER button again during operation. · If TIMER ON and/or TIMER OFF are set, TIMER CANCEL button cancels every setting. E-12 PLASMACLUSTER OPERATION The Plasmacluster Ion generator inside the air conditioner will release positive and negative plasmacluster ions into the room. Approximately the same numbers of positive and negative ions released into the air will reduce some airborn mold. 1 During operation, press the PLASMACLUSTER button. · The remote control will display " " · The blue PLASMACLUSTER lamp on the unit will light up. TO CANCEL Press the PLASMACLUSTER button again. 1 DISPLAY · The PLASMACLUSTER lamp on the unit will turn off. NOTES: · Use of the PLASMACLUSTER operation will be memorized, and it will be activated the next time you turn on the air conditioner. [. . . ] 2 Put the shaft at the left of the louvre in the shaft receiver of the unit. Make sure the shaft at the center of the louvre is placed in the center shaft receiver of the air outlet. 3 Close the left cover until it clicks. Hole 1 Shaft Shaft Receiver 2 2 5 Connect the poweroncord to the wall outlet or turn the circuit breaker. 3 Cover E-18 ADDITIONAL NOTES ON OPERATION OPERATING TEMPERATURE RANGE INDOOR TEMP. · The built-in protective device may prevent the unit from operating when used out of this range. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AY-XP12DR-NC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AY-XP12DR-NC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.