User manual SHARP AY-XP09DR-NC

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP AY-XP09DR-NC. We hope that this SHARP AY-XP09DR-NC user guide will be useful to you.


SHARP AY-XP09DR-NC : Download the complete user guide (809 Ko)

Manual abstract: user guide SHARP AY-XP09DR-NC

Detailed instructions for use are in the User's Guide.

[. . . ] AY-XP09DR-NC OPERATION MANUAL · Uses ozone layer friendly refrigerant R410A. INDOOR UNIT OUTDOOR UNIT AY-XP09DR-NC AE-X09DR-N ENGLISH SPLIT TYPE ROOM AIR CONDITIONER ENGLISH CONTENTS · PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3 · SETTING DEODORANT DUST COLLECTING FILTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-5 · USING THE REMOTE CONTROL . . . . . . . . . . . E-12 · TIPS ABOUT PLASMACLUSTER OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-20 PRECAUTIONS WARNINGS FOR USE 1 2 3 4 5 6 7 8 Do not pull or deform the power supply cord. [. . . ] AUTO SOFT LOW HIGH · In the DRY mode, the fan speed is preset to AUTO and cannot be changed. 5 To turn off the unit, press the ON/OFF button again. · The red OPERATION lamp ( will turn off. ) on the unit TIPS ABOUT AUTO MODE In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature and outdoor temperature when the unit is turned on. Modes and Temperature Settings During operation, if the outdoor temperature changes, the temperature settings will automatically slide as shown in the chart. 29 21 (¡C) 0 10 18 Cool (24¡C) 28 34 temp. (¡C) outdoor Cool Cool (25¡C) (26¡C) Heat Heat (24¡C) (23¡C) Dry ( Room Temp. ) -2¡C Heat (22¡C) indoor temp. the figures in ( ) are temperature settings E-8 TIPS ABOUT INDICATOR PANEL The indicator panel will change each time you press the DISPLAY button in the following manner. Lamp The outdoor temperature is displayed. No display. NOTES: · The displayed temperatures are rough estimates and may vary from the actual temperatures. · Temperature display ranges is displayed when less than 0°C and when higher Room temperature: 0°C ~ 40°C ( than 40°C) Outdoor temperature: -9°C ~ 45°C ( is displayed when less than -9°C and when higher than 45°C) is displayed during the first 60 seconds of operation while the temperatures are being · detected. · Only the room temperature can be displayed for 5 seconds when the unit is not in operation. PROGRESSIVE AIRFLOW Press the Progressive Air Flow button during cooling or dry operation when you do not want to feel cold air. Condensation may form on the louvres. E-10 10°C OPERATION Heating operation with 10°C set temperature will be performed. AM 1 Press the MODE button and select HEAT mode. · 10°C operation will also be cancelled when the operation mode is changed, or when the unit is turned off. ENGLISH DISPLAY MODE 1h CLEAN FAN SWING SET/C 1 NOTE: · 10°C operation will not be available with heating operation automatically selected by AUTO mode. FULL POWER OPERATION In this operation, the air conditioner works at maximum power to makes the room cool or warm so rapidly that you can use it just after you come home. FULL 1 To activate the button POWER operation, press the FULL POWER during operation. · The remote control will display . · The temperature display will go off. AM TO CANCEL Press the FULL POWER button again. · FULL POWER operation will also be cancelled when the operation mode is changed, or when the unit is turned off. DISPLAY 1 NOTE: · You can not set the temperature and fan speed during the FULL POWER operation. E-11 ONE-HOUR OFF TIMER When the ONE-HOUR OFF TIMER is set, the unit will stop operating after one hour. 1 Press the ONE-HOUR OFF TIMER button. · The remote control displays " ". · The unit will stop operating after one hour. TO CANCEL Press the TIMER CANCEL (SET/C) button. MODE 1h 1 · The orange TIMER lamp ( ) on the unit will turn off. Or, turn the unit off by pressing the ON/OFF button. · The red OPERATION lamp ( ) and the orange TIMER lamp ( ) on the unit will turn off. CLEAN FAN NOTES: · The ONE-HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF operations. · When the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will operate for an hour with the formerly set condition. · If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER activates, press the ONE-HOUR OFF TIMER button again during operation. · If TIMER ON and/or TIMER OFF are set, TIMER CANCEL button cancels every setting. TIPS ABOUT PLASMACLUSTER OPERATION The Plasmacluster Ion generator inside the air conditioner will release Plasmacluster ions, which are collective mass of positive and negative ions, into the room. The Plasmacluster ions reduce airborne mold fungus. AIR CLEAN OPERATION Plasmacluster ions released into the air will reduce airborne mold fungus. ION BALANCE OPERATION Plasmacluster Ion generator Plasmacluster ions It is said that plenty of negative ions exist in places such as waterfalls or waterside in natural environment. In this operation mode, negative ions will be released in an increased rate, in order to bring the room air close to this condition. SELF CLEAN OPERATION Plasmacluster Operation will be performed with FAN or HEAT mode, in order to reduce the growth of mold fungus, and dry inside of the air conditioner unit. Mold fungus already grown can not be eliminated by this operation. E-12 PLASMACLUSTER OPERATION You can choose AIR CLEAN OPERATION or ION BALANCE OPERATION 1 During operation, press the PLASMACLUSTER button to select the mode. AIR CLEAN REMOTE CONTROL DISPLAY PLASMACLUSTER lamp on the unit ION BALANCE CANCEL BLUE lamp light up GREEN lamp light up Lamp goes off 1 DISPLAY · In the AIR CLEAN operation, the blue PLASMACLUSTER lamp on the unit will light up. · In the ION BALANCE operation, the green PLASMACLUSTER lamp on the unit will light up. TO CANCEL Press the PLASMACLUSTER button until PLASMACLUSTER symbol on the remote control display goes off. NOTES: · The PLASMACLUSTER lamp on the unit will turn off. · Setting of the PLASMACLUSTER operation will be memorized and will operate in the same mode, the next time you turn on the air conditioner. · To turn off the PLASMACLUSTER lamp, press the DISPLAY button. · When the PLASMACLUSTER button is pressed while the unit is not operating, the PLASMACLUSTER operation will be performed without accompanying air conditioning mode (eg, HEATING or COOLING). The mode symbol of the remote control will go off and the fan speed can not be set AUTO. SELF CLEAN OPERATION 1 Press the SELF CLEAN button when the unit is not operating. · The remote control displays " ". · The remaining operation time will be indicated on the TEMPERATURE INDICATOR of the indoor unit in minute decrements. MODE 1h CLEAN FAN 1 TO CANCEL Press the SELF CLEAN button. [. . . ] 2 Put the shaft at the left of the louvre in the shaft receiver of the unit. Make sure the shaft at the center of the louvre is placed in the center shaft receiver of the air outlet. 3 Close the left cover until it clicks. Hole 1 Shaft Shaft Receiver 2 2 5 Connect the poweroncord to the wall outlet or turn the circuit breaker. 3 Cover E-18 ADDITIONAL NOTES ON OPERATION OPERATING TEMPERATURE RANGE INDOOR TEMP. · The built-in protective device may prevent the unit from operating when used out of this range. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AY-XP09DR-NC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AY-XP09DR-NC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.