User manual SHARP AH-AP18FMF

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP AH-AP18FMF. We hope that this SHARP AH-AP18FMF user guide will be useful to you.


SHARP AH-AP18FMF : Download the complete user guide (477 Ko)

Manual abstract: user guide SHARP AH-AP18FMF

Detailed instructions for use are in the User's Guide.

[. . . ] Improper cable connection can cause the power supply cord, plug and the electrical outlet to overheat and cause fire. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Use only the manufacturespecified power cord for replacement. WARNINGS FOR INSTALLATION / REMOVAL / REPAIR · Do not attempt to install/remove/repair the unit by yourself. Consult your dealer or other qualified service personnel for the installation/removal/repair of the unit. 3 IMPORTANT SAFETY INSTRUCTIONS CAUTIONS FOR USE periodically to 1 Open a window or door ventilation may ventilate the room, especially when using gas appliances. [. . . ] · Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal. · The unit can be affected by signals transmitted from the remote control of a television, VCR or other equipment used in the same room. · Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit and remote control from moisture and shock which can discolour or damage them. 9 BASIC OPERATION 1 Press the MODE button to select the operation mode. AUTO COOL DRY 2 2 5 3 1 4 Press the ON/OFF button to start operation. · The red OPERATION lamp ( unit will light. button to set the desired temperature. AUTO/DRY MODE The temperature can be changed in 1°C increments within the range of 2°C higher to 2°C lower from the temperature automatically determined by the air conditioner. COOL MODE The temperature can be set within the range of 18 to 32°C. TIPS ABOUT AUTO MODE In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature when the unit is turned on. 4 Press the FAN button to set the desired fan speed. AUTO SOFT LOW HIGH Modes and Temperature Settings Room temp. Automatic Operation at operation start-up Mode Temperature Setting Below 24°C DRY Room Temp. at start-up 24°C-26°C COOL 24°C 26°C-28°C COOL 25°C Above 28°C COOL 26°C · In the DRY mode, the fan speed is preset to AUTO and cannot be changed. 5 To turn off the unit, press the ON/ OFF button again. · The red OPERATION lamp ( unit will turn off. ) on the 10 ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION Press the SWING button on the remote control once. · The vertical adjustment louvre will change its angle continuously. Press the SWING button again when the vertical adjustment louvre is at the desired position. · The louvre will stop moving within the range shown in the diagram. · The adjusted position will be memorized and will be automatically set to the same position when operated the next time. Adjustment range The adjustment range is narrower the SWING range in order to prevent condensation from dripping. HORIZONTAL AIR FLOW DIRECTION Hold the horizontal adjustment louvre as shown in the diagram and adjust the air flow direction. CAUTION Never attempt to adjust the vertical adjustment louvres manually. · Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction when the remote control is used for adjustment. · When the vertical adjustment louvre is positioned at the lowest position in the COOL or DRY mode for an extended period of time, condensation may result. Do not adjust the horizontal adjustment louvre to the extreme left or right in the COOL mode with the fan speed set to "SOFT( )" for an extended period of time. Condensation may form on the louvres. 11 PLASMACLUSTER OPERATION The Plasmacluster ion generator inside the air conditioner will release positive and negative Plasmacluster ions into the room. Approximately the same numbers of positive and negative ions released into the air will reduce some airborne mold. 1 During operation, press the PLASMACLUSTER button. · The remote control will display " ". · If the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will operate for an hour at the formerly set condition. · If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER is activated, press the ONE-HOUR OFF TIMER button again during operation. 13 TIMER OPERATION TIMER OFF The unit will turn off automatically according to your setting. Timer duration can be set from a minimum half an hour (30 minutes) to a maximum of 12 hours. Up to 9. 5 hours, you can set in half-hour (30-minute) increments, and from 10 to 12 hours, in 1-hour increments. Point the remote control at the signal receiver window on the unit. 1 Press the TIMER OFF ( the time as desired. 0. 5h 1. 0h 1. 5h ) button and set · The time setting will change as you press the button as follows, 10h 11h 12h Hold the button down to speed through the settings. 1 · The orange TIMER lamp ( ) on the unit will light. [. . . ] This sound is generated by the friction of the front panel and other components expanding or connecting due to a temperature change. ODOR EMITTED FROM THE PLASMACLUSTER AIR OUTLET This is the smell of ozone generated from the Plasmacluster ion generator. The ozone concentration is very small, posing no adverse effect on your health. The ozone discharged into the air rapidly decomposes, and its density in the room will not increase. A LOW BUZZING NOISE EMITTED This is a sound emitted when the unit is generating Plasmacluster ions. If the unit appears to be malfunctioning, check the following points before calling for service. IF THE UNIT FAILS TO OPERATE · Check to see if the circuit breaker has tripped or the fuse has blown. All lamps on the indicator panel will blink when the louver unit is not properly installed. IF THE UNIT FAILS TO COOL THE ROOM EFFECTIVELY Check the filters. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AH-AP18FMF




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AH-AP18FMF will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.