User manual SHARP AF-S60EX

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP AF-S60EX. We hope that this SHARP AF-S60EX user guide will be useful to you.


SHARP AF-S60EX : Download the complete user guide (679 Ko)

Manual abstract: user guide SHARP AF-S60EX

Detailed instructions for use are in the User's Guide.

[. . . ] Read these instructions carefully before installing or operating your air conditioner. The INSTALLATION AND OPERATION MANUAL should be kept in a safe place for handy reference. HOW TO OPERATE · PARTS NAMES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 As an ENERGY STAR Partner, Sharp Electronics has determined that this product (AF-S60EX, AFS120DX) meets the ENERGY STAR guidelines for energy efficient air conditioners. To meet these guidelines, air conditioners must be at least 10% more efficient than the minimum Federal standard. FOR YOUR PROTECTION To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the right side of the unit. MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE Dealer Name Address City State Zip Telephone TO PHONE: Dial 1-800-BE-SHARP (237-4277) for: SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 Please provide the following information when you write or call: model number, serial number, date of purchase, your complete mailing address (including zip code), your daytime telephone number (including area code) and description of the problem. 2 CONSUMER LIMITED WARRANTY CONSUMER LIMITED WARRANTY SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below. [. . . ] (3) Secure the closure assemblies to the sill with 2 screws (L=1", 25. 4 mm). 8 9 (1) Slide the chassis back into the cabinet. (2) Replace the 4 screws removed in step 3 to the top and side of the cabinet . (1) Replace the front panel. Slip the exhaust lever through the opening between the horizontal louver and the front panel then, hook the cabinet top. Horizontal Louver CAUTION: Take care not to damage the exhaust lever with the front panel. (2) Screw the front cabinet on at the bottom corners with 2 screws removed in step 2. Front Panel Exhaust Lever 10 Cut the window sash foam seal to the proper length and seal the opening between the top of the inside window sash and the outside window sash. Window sash foam seal 7 PRECAUTIONS CAUTION FOR USE IMPORTANT: Points to keep in mind when using your air conditioner. · Install the air conditioner by following the installation instructions given in the previous section of this manual. · Make sure the unit is the correct capacity for the area you want to cool. · Push the AC power plug securely into the receptacle and make sure it is not loose. · Use power circuit with a proper voltage rating. Use a three-pronged grounded electrical outlet rated 125V, 60Hz, 15 amp or more, AC only as shown on right. Use of an improper voltage rating power circuit can result in damage to the unit and possibly fire. · Always use a fuse with the proper amp rating. · Use of extension cords of any kind is not recommended. Two-Pole, 3-wire Grounding Receptacle 15 Amps. 125V. Do not, under any circumstances, use wire, pins or other objects in place of the proper fuse. The EXHAUST lever should normally be kept in the CLOSED position during cooling for maximum efficiency. EXHAUST Lever CLOSED OPEN 13 HOW TO OPERATE ON TIMER OPERATION · This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance. You can set the timer to start in increments of 30 minutes (0. 5 hours) up to 9. 5 hours in advance of the start time, or in 1 hour increments from 10 to 12 hours in advance of the start time. · The unit will start automatically according to your setting. When the unit is not operating SELECTOR indicator 1 ENERGY SAVER POWER ON/OFF Touch the TIMER ON/OFF pad to set the delayed start time. · The time setting will change as you touch the pad. The display will change as follows; Preset(0. 5h) F hr SELECTOR TEMP COOL / FAN TIMER ON/OFF Previous setting 0. 5h 1. 0h 1. 5h 12h 10h 11h CL(cancel) TIMER ON/OFF pad TIMER indicator (If you wish to start the operation 6 hours and 30 minutes later, set the delay time as shown above. ) · The timer will be set, 5 seconds after the TIMER ON/OFF pad is touched for the last time. The temperature setting will be displayed. TO CANCEL THE TIMER SETTING Touch the TIMER ON/OFF pad again after the timer is set, or press the TIMER ON/OFF pad until CL(cancel) appears on the display. NOTES FOR TIMER SETTING AND OPERATION: · After setting the TIMER, change the temperature and fan speed settings as shown on pages 11 and 12. When the temperature is set in the timer mode, the temperature will show in the display for 5 seconds and then return to the time display. · The last setting used will be memorized and will appear on the display the next time you operate the unit with the TIMER function. · If a power failure occurs while the ON or OFF TIMER is set, the TIMER memory will be cancelled and will not resume even after power is reinstated. · OFF TIMER OPERATION can also be set with the REMOTE CONTROL. 14 HOW TO OPERATE OFF TIMER OPERATION · This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance. You can set the timer to stop in increments of 30 minutes (0. 5 hours) up to 9. 5 hours in advance of the stop time, or in 1 hour increments from 10 to 12 hours in advance of the stop time. · The unit will stop automatically according to your setting. When the unit is operating 1 F hr Touch the TIMER ON/OFF pad to set the delayed stop time. · The time setting will change as you touch the pad. [. . . ] Fan speed and operation mode selections are shown to the right. SET TIMER/OFF button Push to set delay "OFF" timer during operation. · The time setting will change as you push the button. The display will change as follows; Preset(0. 5h) Previous setting 0. 5h 1. 0h 12h 1. 5h 11h 10h CL(cancel) · The last OFF time setting is memorized by the unit and will appear on the display when the button is pushed. · The timer will be set, 5 seconds after the SET TIMER/OFF button is pushed for the last time. · If you wish to cancel the timer, push the SET TIMER/OFF button again after the time is set or, push the SET TIMER/OFF button until CL (cancel) appears on the display. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AF-S60EX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AF-S60EX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.