User manual SHARP AF-Q100PX

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP AF-Q100PX. We hope that this SHARP AF-Q100PX user guide will be useful to you.


SHARP AF-Q100PX : Download the complete user guide (4901 Ko)

Manual abstract: user guide SHARP AF-Q100PX

Detailed instructions for use are in the User's Guide.

[. . . ] The INSTALLATION AND OPERATION MANUAL should be kept in a safe place for handy reference. PRECAUTIONS · CAUTION FOR USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 HOW TO OPERATE · PARTS NAMES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 As an ENERGY STAR Partner, Sharp Electronics has determined that this products (AF-Q100PX) meet the ENERGY STAR guidelines for energy efficient air conditioners. To meet these guidelines, air conditioners must be at least 10% more efficient than the minimum Federal standard. FOR YOUR PROTECTION To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the right side of the unit. MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE Dealer Name Address City State Zip Telephone TO PHONE: Dial 1-800-BE-SHARP (237-4277) for: SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 Please provide the following information when you write or call: model number, serial number, date of purchase, your complete mailing address (including zip code), your daytime telephone number (including area code) and description of the problem. 2 CONSUMER LIMITED WARRANTY CONSUMER LIMITED WARRANTY SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below. [. . . ] · Push the AC power plug securely into the receptacle and make sure it is not loose. · Use power circuit with a proper voltage rating. Use a three-pronged grounded electrical outlet rated 125V, 60Hz, 15 amp or more, AC only as shown on right. Use of an improper voltage rating power circuit can result in damage to the unit and possibly fire. · Always use a fuse with the proper amp rating. · Use of extension cords of any kind is not recommended. Two-Pole, 3-wire Grounding Receptacle 15 Amps. 125V. Do not, under any circumstances, use wire, pins or other objects in place of the proper fuse. If you still elect to use an extension cord, it is absolutely necessary that it be a UL Listed 3-wire grounding type appliance extension cord rated 125 Volts, 15 amp or more. · Ventilate the room periodically during use, especially if using gas appliances. GROUNDING INSTRUCTIONS WARNING: Improper use of the grounding plug can result in the risk of electric shock. This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. WARNING: Do not under any circumstances cut or remove the round grounding prong from this plug. If it is necessary to use an extension cord, use only a UL Listed 3-wire extension cord that has a 3blade grounding plug, and a 3-slot receptacle that will accept the plug on the appliance. The marked rating of the extension cord should be AC 125 Volt, 15 Amp or more. Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. · The last setting used will be memorized and will appear on the display the next time you operate the unit with the TIMER function. · If a power failure occurs while the ON or OFF TIMER is set, the TIMER memory will be cancelled and will not resume even after power is reinstated. · OFF TIMER OPERATION can also be set with the REMOTE CONTROL. 14 HOW TO OPERATE OFF TIMER OPERATION · This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance. You can set the timer to stop in increments of 30 minutes (0. 5 hours) up to 9. 5 hours in advance of the stop time, or in 1 hour increments from 10 to 12 hours in advance of the stop time. · The unit will stop automatically according to your setting. When the unit is operating 1 F hr Touch the TIMER ON/OFF pad to set the delayed stop time. · The time setting will change as you touch the pad. The display will change as follows; COOL / FAN TEMP ENERGY SAVER SELECTOR TIMER ON/OFF POWER ON/OFF Preset(0. 5h) Previous setting 0. 5h 1. 0h 1. 5h 12h 10h 11h CL(cancel) TIMER ON/OFF pad TIMER indicator (If you wish to stop the operation 10 hours later, set the delay time as shown above. ) · The timer will be set, 5 seconds after the TIMER ON/OFF pad is touched for the last time. All indicators and displays will go out. TO CANCEL THE TIMER SETTING Touch the TIMER ON/OFF pad again after the timer is set or, press the TIMER ON/OFF pad until CL(cancel) appears on the display. 15 HOW TO OPERATE USING THE REMOTE CONTROL INSTALLING BATTERIES Use two AA (R6) batteries. 1 2 3 Remove the battery compartment cover. Insert the batteries in the compartment, making sure the and polarities are properly aligned. Replace the cover. Battery compartment cover NOTES: · The battery life is approximately one year with normal use. · When you replace the batteries, always use two new ones of the same type. · If the remote control does not operate normally after replacing the batteries, take out the batteries and replace them again after 30 seconds. [. . . ] · The "ON" TIMER cannot be set with the remote control. It can only be activated by the TIMER ON/OFF pad on the unit's control panel ( See page 14 ). To change temperature setting when ON/OFF timer is in use 1. The current set temperature will be recalled on the unit's display. The new set temperature will show on the display for 5 seconds and return to the time display. 17 HOW TO OPERATE PLASMACLUSTER OPERATION Cluster ions are released into the room, keeping air your room clean. During operation PLASMACLUSTER button 1 ON / OFF Press PLASMACLUSTER button. · PLASMACLUSTER indicator will light. PLASMACLUSTER indicator TEMP. F hr SELECTOR COOL / FAN TEMP ENERGY SAVER SELECTOR TIMER ON/OFF POWER ON/OFF SET TIMER / OFF POWER ON / OFF 2 To cancel, press PLASMACLUSTER button again. · PLASMACLUSTER indicator will go off. NOTE: PLASMACLUSTER operation will be memorized when once set and will start its operation the next time the unit is turned on. 18 HOW TO OPERATE NOTE FOR PLASMACLUSTER OPERATION The ionizer inside the air conditioner will discharge cluster ions, which are collective mass of positive and negative ions, into the room. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AF-Q100PX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AF-Q100PX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.