User manual SENNHEISER SR 2050 IEM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SENNHEISER SR 2050 IEM. We hope that this SENNHEISER SR 2050 IEM user guide will be useful to you.


SENNHEISER SR 2050 IEM : Download the complete user guide (8348 Ko)

You may also download the following manuals related to this product:

   SENNHEISER SR 2050 IEM (8143 ko)
   SENNHEISER SR 2050 IEM (8420 ko)
   SENNHEISER SR 2050 IEM (8216 ko)
   SENNHEISER SR 2050 IEM 01-09 (8216 ko)
   SENNHEISER SR 2050 IEM 01-09 (8143 ko)
   SENNHEISER SR 2050 IEM (5384 ko)
   SENNHEISER SR 2050 IEM 01-09 (8287 ko)
   SENNHEISER SR 2050 IEM ANNEXE 110 (8287 ko)

Manual abstract: user guide SENNHEISER SR 2050 IEM

Detailed instructions for use are in the User's Guide.

[. . . ] SR 2000 IEM SR 2050 IEM Instruction manual Contents Contents Important safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 The SR 2000 IEM and SR 2050 IEM transmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 The frequency bank system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Areas of application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] When in the operating menu, pressing the STANDBY button º will cancel your entry (ESC function) and return you to the standard display. The STANDBY button º is backlit in red both during operation and in standby mode. To completely switch the transmitter off: Disconnect the transmitter from the mains by unplugging the mains plug from the wall socket. The backlighting of the STANDBY button º goes off. Deactivating the lock mode temporarily You can activate or deactivate the automatic lock mode via the "Auto Lock" menu item (see page 25). If the lock mode is activated, you have to temporarily deactivate it In order to be able to operate the transmitter: Press the jog dial. ­ When you are in the operating menu, the lock mode remains deactivated until you exit the operating menu. ­ When the standard display is shown, the lock mode is automatically activated after 10 seconds. The lock mode icon PEAK PEAK flashes prior to the lock mode being activated again. 0 -10 -20 -30 -40 AF I 0 -10 -20 -30 -40 AF II B. Ch: 5. 14 **2000** 552. 300 MHz EQ Standard -18dB Activating/deactivating the RF signal To deactivate the RF signal: When the standard display is shown on the display panel, press the STANDBY button. "RF Mute On?" appears on the display panel. 14 Using the transmitter Press the jog dial. In addition, the display backlighting changes from orange to red and "RF Mute" flashes in alternation with the standard display. The RF signal is activated and the transmission icon backlighting changes from red to orange. To deactivate the RF signal on switch-on: See "offline operation" on page 13. Listening at high volume levels for long periods can lead to permanent hearing defects. Set the headphone volume control » to the minimum position before putting the headphones on. Do not continuously expose yourself to high volumes. PEAK PEAK Set the headphone volume control » to the minimum position. Connect headphones with a ¼" (6. 3 mm) stereo jack plug to the headphone output ·. Gradually increase the volume and monitor the audio signal with the lowest possible volume. Stereo Transmitter SR 2000 IEM 0 -10 -20 -30 -40 AF I 0 -10 -20 -30 -40 AF II Synchronizing transmitters and EK 2000 IEM receivers via the infra-red interface Synchronization allows you to quickly and easily transfer transmitter and receiver settings from one device to the other, especially if you want to configure a multi-channel system. Easy Setup Sync: Transfer from the receiver to one or several transmitters Once you have performed a frequency preset scan with a receiver, you can use the Easy Setup Sync function to transfer unused frequency presets from the receiver to the transmitters via the infra-red interface. In order to set up a multi-channel system, you use the diversity receiver to transfer the first unused channel from the selected frequency bank to the first transmitter and the next unused channel to the second transmitter and so on, thus ensuring that all transmitters of a multi-channel system operate on suitable frequencies. Sync: Transfer from a transmitter to a receiver Once you have selected and set the desired receiver settings on the transmitter (either manually or using the Easy Setup Sync function), you transfer these settings to a receiver. This configures the receiver and establishes a transmission link between transmitter and receiver. 15 Using the transmitter When carrying out the Sync function, the transmitter's current frequency bank and channel setting as well as the receiver parameters adjusted via the "Sync Settings" submenu (see page 27) are transferred to the EK 2000 IEM receiver via the infra-red interface. Carrying out an Easy Setup Sync or a Sync function The following assumes that you are using the Easy Setup Sync function for setting up a multichannel system. You can also use the Easy Setup Sync function for establishing a transmission link between one transmitter and one EK 2000 IEM receiver. [. . . ] · When using several transmitters simultaneously, interference can be avoided by maintaining a minimum distance of 20 cm between two transmitters. · Use accessories recommended by Sennheiser for multi-channel applications (see page 34). 33 Accessories Accessories Cat. 004368 502048 500887 003658 004645 087969 002324 Accessory GA 3030 AM antenna front mount kit AC 3200 antenna combiner A 5000 CP circularly polarized broadband antenna A 2003 directional broadband antenna A 1031 omni-directional broadband antenna Antenna daisy-chain cable, 50 , BNC, 0. 25 m GZL 1019-A1 coaxial cable, type RG 58, BNC to BNC, 1 mm 34 If a problem occurs . . . If a problem occurs . . . Problem Possible cause Possible solution Deactivate the lock mode (see page 14). Transmitter cannot be Lock mode is activated operated, "Locked" appears on the display panel No operation indication No RF signal at the receiver No mains connection Transmitter and receiver are not on the same channel If "RF Mute" additionally appears on the transmitter display: RF signal is deactivated Very weak RF signal at the receiver Transmission range is exceeded Check the connections of the mains cable. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SENNHEISER SR 2050 IEM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SENNHEISER SR 2050 IEM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.