User manual SENNHEISER SKP 300 G3

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SENNHEISER SKP 300 G3. We hope that this SENNHEISER SKP 300 G3 user guide will be useful to you.


SENNHEISER SKP 300 G3 : Download the complete user guide (4621 Ko)

Manual abstract: user guide SENNHEISER SKP 300 G3

Detailed instructions for use are in the User's Guide.

[. . . ] SKP 300 Instruction manual Contents Contents Important safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 The SKP 300 G3 plug-on transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Areas of application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 The frequency bank system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Delivery includes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Overview of the SKP 300 G3 plug-on transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Overview of the displays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Putting the plug-on transmitter into operation. . . . . . . . . . . . . 8 Inserting the batteries/accupack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Charging the accupack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Plugging the plug-on transmitter onto a microphone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Using the plug-on transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Muting the audio signal or deactivating the RF signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Using the operating menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 The buttons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] allowing you to check the adjusted sensitivity before live operation. B. Ch: 19. 24 543. 850 MHz AF P MUTE Input sensitivity adjusted . . . too high Close talking distances, speakers with loud voices or loud music passages cause overmodulation in the transmission link. The audio level display "AF" 1 shows full deflection for the duration of the overmodulation. correctly The audio level display "AF" 1 shows full deflection only during the loudest passages. This results in a signal with high background noise. Adjust a low input sensitivity when using condenser microphones, adjust a high input sensitivity when using dynamic microphones. SKP 300 G3 | 17 Adjusting settings via the operating menu Selecting the frequency bank and the channel manually ­ "Frequency Preset" Menu Frequency Preset B. Ch: 18. 24 Call up "Frequency Preset" Frequency Preset B. Ch: 18. 24 546. 550MHz Select the frequency bank and confirm Frequency Preset B. Ch: 19. 24 538. 475MHz Select the channel; store the setting "Stored" When you are in the "Frequency Preset" menu item, the RF signal is deactivated. Overview of the frequency banks and channels: Frequency bank Channels "1" to "20" up to 24 per frequency bank "U1" to "U6" Type System bank: frequencies are factory-preset up to 24 per User bank: frequency frequencies are bank freely selectable When setting up multi-channel systems, please observe the following: Only the factory-preset transmission frequencies within one frequency bank ("1" to "20") are intermodulation-free. Entering a name ­ "Name" Menu Name Lichael Name Lichael Enter a character and confirm Name Michael Enter a character; store the setting Call up "Name" "Stored" Via the "Name" menu, you can enter a freely selectable name for the plug-on transmitter. The name can be displayed on the standard displays "Frequency/Name" and "Name/Channel" (see page 13) and can consist of up to 8 characters such as: · · · letters (without pronounciation marks), numbers from 0 to 9, special characters and spaces. To enter a name, proceed as follows: Press the UP/DOWN button to select a character. SET Press the SET button to change to the next segment/character or to store the complete entry. 18 | SKP 300 G3 Adjusting settings via the operating menu Activating/deactivating the automatic lock mode ­ "Auto Lock" Menu Auto Lock Active Call up "Auto Lock" Auto Lock Active Select the desired setting Auto Lock Inactive Store the setting "Stored" The lock mode prevents that the plug-on transmitter is accidentally switched off or programed during operation. The lock mode icon 5 on the current standard display indicates that the lock mode is activated. For information on how to use the lock mode, refer to page 11. The extended menu "Advanced Menu" Setting the transmission frequencies for the frequency banks "U1" to "U6" ­ "Tune" When you have selected one of the system banks and then select the "Tune" menu item, the plug-on transmitter automatically switches to channel 1 of the frequency bank "U1". Upon delivery, the channels of the frequency banks "U1" to "U6" are not assigned a transmission frequency. When you are in the "Tune" menu item, the RF signal is deactivated. set a transmission frequency to be stored in the current channel of the frequency bank ("U1" to "U6") 2. or select a frequency bank ("U1" to "U6") and a channel and assign this channel a transmission frequency. It is vital to observe the notes on frequency selection on page 23. SKP 300 G3 | 19 Adjusting settings via the operating menu Setting a transmission frequency for the current channel Press the UP/DOWN button until the "Tune" menu item appears. SET Press the SET button. The frequency selection appears. Tu n e 543 . 850 MHz B. Ch: U1. 1 Select the MHz value and confirm Advanced Menu Tune Call up "Tune" Tu n e 543. 850MHz B. Ch: U1. 1 Select the kHz value; store the setting "Stored" Set the desired frequency. SET Press the SET button. You are back to the operating menu. Selecting a frequency bank and a channel and assigning this channel a transmission frequency Press the UP/DOWN button until the "Tune" menu item appears. SET Keep the SET button pressed until the frequency bank selection appears. Tu n e 543. 850MHz B. Ch: U1. 1 Select the frequency bank and confirm Advanced Menu Tune Call up "Tune" (special function) Tu n e 543. 850MHz B. Ch: U1. 1 Select the channel; store the setting "Stored" Set the desired frequency bank and the desired channel. SET Press the SET button. The frequency selection appears. Set the desired frequency. 20 | SKP 300 G3 Adjusting settings via the operating menu Setting the mode for the MUTE switch ­ "Mute Mode" Advanced Menu Mute Mode Call up "Mute Mode" Mute Mode AF On/Off Select the desired setting Mute Mode RF On/Off Store the setting "Stored" Mode Function "AF On/Off" When the switch is in the MUTE position, no audio signal is transmitted. "RF On/Off" When the switch is in the MUTE position, the RF signal is deactivated. "Disabled" The muting function is deactivated. For information on how to use the MUTE switch 9 refer to page 12. Adjusting the transmission power ­ "RF Power" Advanced Menu RF Power Call up "RF Power" RF Power Standard Select the desired setting RF Power Low Store the setting "Stored" Via the "RF Power" menu item, you can adjust the transmission power in 2 steps ("Low" and "Standard"). [. . . ] 30 mW ("Standard") Pilot tone squelch can be switched off AF characteristics Compander system Sennheiser HDX AF frequency response 80 to 18, 000 Hz Signal-to-noise ratio (1 mV, peak deviation) 120 dBA THD 0. 9% Max. input voltage 6 Vrms Input impedance 6 k, balanced Adjustment range of 48 dB, adjustable in steps of input sensitivity 6 dB Overall device Temperature range Power supply Nominal voltage Power consumption ­10°C to +55°C 2 AA size batteries, 1. 5 V or BA 2015 accupack 2. 4 V at nominal voltage: · typ. 210 mA (10 mW RF, w/o P48) with switched-off plug-on transmitter: · 25 A typ. 195 g Modulation Frequency ranges Operating time Dimensions Weight (incl. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SENNHEISER SKP 300 G3




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SENNHEISER SKP 300 G3 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.