Detailed instructions for use are in the User's Guide.
[. . . ] W 300
Instructions for use
Thank you for choosing Sennheiser!
We have designed this product to give you reliable operation over many years. Over half a century of accumulated expertise in the design and manufacture of high-quality electro-acoustic equipment have made Sennheiser a world-leading company in this field. Please take a few moments to read these instructions carefully, as we want you to enjoy your new Sennheiser products quickly and to the fullest.
48
Contents
The evolution wireless series ew 300 G2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
The channel bank system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] With the transmitters, the current setting that can be adjusted flashes on the display. With the receiver, the name of the menu and the current setting are displayed.
Adjusting a setting Press the / buttons to adjust the setting. By briefly pressing the / buttons, the display jumps either forwards or backwards to the next setting. In the "Channel", "Tune" and "Name" menu, the / buttons feature a "fast search" function. The "fast search" function allows you to get fast and easily to your desired setting. With the transmitters, the new setting flashes on the display until it is stored.
Storing a setting Press the SET button to store the setting. "Stored" appears on the display, indicating that the setting has been stored. With most menus, new settings become effective immediately without having to be stored. An exception are the "BANK", "CHAN", "TUNE" and "RESET" menus of the transmitters and the "Reset" menu of the receiver. With these menus, new settings only become effective after they have been stored and "Stored" had appeared on the display.
67
Exiting the operating menu Select the "Exit" menu to exit the operating menu and to return to the standard display. When you have entered the operating menu, the ON/OFF button or the ON button (EM 300 G2 receiver only) serves as the ESC (cancel) key, i. e. by briefly pressing the ON/OFF or POWER button, you cancel your entry and return to the standard display.
68
Operating menu of the receiver
SET
Exit Menu Exit Bank Channel
SET
1 01
Bank 1. 01 B. CH
786. 300 MHz
Bank 3. 01 B. CH
/
790. 250 MHz
Current channel bank
: 1. . . 8, U (User Bank)
Changing the channel bank
SET: Stores the setting
Stored Menu Bank 3 Channel 01 Tune 786. 400MHz
Changing the channel SET
Channel 3. 01 790. 250 MHz B. CH
Current channel and corresponding frequency
Channel 3. 08 807. 900 MHz B. CH
/ : Channel 01. . . 08
SET: Stores the setting
Stored Menu Channel 08 Tune 807. 900MHz Scan
Setting the frequency for channel bank "U" SET
Tune U. 01 B. CH
786. 300 MHz
Tune U. 01 B. CH
797. 075 MHz
Current frequency on the selected channel
/ : Receiving frequency in steps of 25 kHz
SET: Stores the setting
Stored Menu Tune Scan AF Out
SET Scan
797. 075MHz +18
Channel list Scan new Scan reset
Channel list = Last scan result, Scan new = Starts a new scan, Scan reset = Deletes the last scan result SET
Scan new
SET = Starts a new scan SET
Scan reset
SET: Deletes the scan result and releases locked channels SET
Scanning the channel banks for free channels
Scan 1. 01 786. 300 MHz B. CH
Scans all channel banks for free channels
Bank 1 2 3 Free 08 08 03 Bank 5 6 7 Free 06 08 02
4 04 8U 01 08
Bank 1 2 3 Free 08 08 08 Bank 5 6 7 Free 08 08 08
4 08 8U 08 08
Number of free channels per channel bank / : Selects a channel bank SET: Changes to the "Channel" menu SET
Bank 1 2 3 Free 02 08 02 Bank 5 6 7 Free 04 05 08
4 08 8U 03 08
/ : Selects a channel bank SET: Changes to the "Channel" menu
Channel 1. 03 790. 600 MHz B. CH
Channel and corresponding frequency / : Channel 01. . . 08 SET: Stores the setting SET
Number of free channels per channel bank / : Selects a channel bank SET: Changes to the "Channel" menu
SET
SET
STORED Stored AF Out +18
69
Scan
Menu Scan AF Out Squelch
SET
AF Out +18
Current audio output level
AF Out 24
/ : +18 . . . 0. . . 24 dB
+18 High
Setting the audio output level
(in steps of 6 dB)
SET: Stores the setting
Stored Menu AF Out Squelch Display
SET
24 Low
Squelch Low
Current squelch threshold
Squelch High
/ : Low, Mid, High
Setting the squelch threshold
SET: Stores the setting
Stored Menu Squelch High Display Main Name VOCAL
Switching between the standard displays SET
Display Main
Current standard display
Display Frequency
/ : Main, Frequency, Bank/Channel, Name, AFMeter, Second RF SET: Stores the setting
Stored
Main
Frequency
Bank/Channel
Name
AF-Meter
Second RF
Menu Display Name Reset
SET
Frequency VOCAL
Name OCAL
Current receiver name
Name G CAL
/ : Name (10 characters) Letters w/o pronounciation marks, numbers from 0. . . 9, special characters, spaces
Assigning the receiver a name
Stored
SET: 9 x next character, then store
Menu Name Reset Pilot
SET
GUITAR On
Reset Reset?Yes
/ : No, Yes "reset"= Yes: SET: Receiver loads factorypreset default settings (only pilot tone setting is kept), receiver is restarted, standard display appears "reset"= No: SET: Reset is cancelled
Loading the factory-preset default settings
Pilot
On/Off
70
Reset
Menu Reset Pilot Lock
SET
Pilot On
Pilot tone evaluation activated or deactivated
Pilot Off
/ : On, Off SET: Stores the setting
On Off
Activating/deactivating the pilot tone evaluation
STORED Menu Pilot Off Lock Off LCD Contr IIIIII. . . . .
Activating the lock mode SET
Lock Off
Lock mode activated or deactivated
Lock On
/ : On, Off Lock mode = On: SET: Stores the setting, returns to standard display
STORED
Lock mode = Off: SET: Stores the setting
Menu Lock On LCD Contr IIIIII. . . . . Exit
Adjusting the contrast of the graphic display
SET
LCD Contrast IIIIII. . . . . . . . . .
Current contrast setting
LCD Contrast IIIIIIIIII. . . . . .
/ :
16 steps
SET: Stores the setting
STORED
Menu LCD Contr Exit Bank
SET
IIIIIIIIII. . . . . . 1
Exiting the operating menu
Bank
1
71
Operating menu of the transmitters
EXIT
SET
BANK
Changing the channel bank
SET
BANK 1
Current channel bank
BANK U
/ : 1. . . 8, U (User
Bank) SET: Stores the setting
STORED CHAN
Changing the channel SET
1. 03
B. CH
/
1. 02
: Channel
B. CH
Current channel (display depends on "DISPLY" setting)
01. . . 08
SET: Stores the setting
STORED TUNE
Setting the frequency for channel bank "U" SET
790. 025
MHz
791. 125
MHz
Current frequency on the selected channel
/ : Transmission frequency in steps of 25 kHz
STORED SENSIT
Setting the sensitivity SET
-10 dB
Current sensitivity setting
/
-30 dB
: SK 300 G2: 0. . . -30 dB SKM 300 G2: 0. . . -30 dB SET: Stores the setting
STORED
SET
DISPLY
Switching between the standard displays
FREQ
Current standard display
/
NAME
: FREQ, NAME, CHAN SET: Stores the setting
STORED NAME
72
DISPLY
NAME
Assigning the transmitter a name
SET
VOCAL
Current transmitter name
GUCAL
/:
Name (6 characters)
Letters w/o pronounciation marks, numbers from 0. . . 9, special characters, spaces
STORED
SET: 5 x next character, then store
RESET
Loading the factorypreset default settings
SET
RST. OK
: OK, NO "reset" = OK: SET: Transmitter loads
factory-preset default settings (only pilot tone setting is kept), transmitter is restarted, standard display
"reset" = NO SET: Reset is cancelled
PILOT
Activating/deactivating the pilot tone transmission
SET
PLT. OFF
/ : ON, OFF
SET: Stores the setting
STORED LOCK
Activating the lock mode SET
LOC. OFF OFF
Lock mode activated or deactivated
LOC. ON ON
/ : ON, OFF Lock mode = ON: SET: Stores the setting
(STORED), returns to standard display
STORED EXIT
Exiting the operating menu SET
Lock mode = OFF: SET: Stores the setting
BANK
73
Adjustment tips for the operating menu
Switching between channel banks BANK Bank
Via the "Bank" menu, you can switch between the nine channel banks. The channel banks "1" to "8" have eight switchable channels that are factorypreset to a transmission/receiving frequency (see "The channel bank system" on page 50). The channel bank "U" (user bank) has eight switchable channels to store your selection out of 1440 transmission/receiving frequencies that are freely selectable within the preset frequency range. When switching from one channel bank to another, the channel with the lowest channel number is automatically displayed. If, during the last scan of this channel bank, an interfering frequency was detected on the channel with the lowest channel number (see "Scanning the channel banks for free channels (EM 300 G2 only)" on page 75), the receiver display panel automatically displays the next free channel.
Switching between the channels in a channel bank CHAN Channel
Via the "Channel" menu, you can switch between the eight channels in a channel bank. [. . . ] Ihre gesetzlichen Mängelansprüche aus dem Kaufvertrag gegen den Verkäufer werden durch diese Garantie nicht eingeschränkt. Die Garantie kann weltweit in allen Ländern außer in den USA in Anspruch genommen werden, in denen das jeweils nationale Recht unseren Garantiebestimmungen nicht entgegensteht
ENGLISH
The guarantee period for this Sennheiser product is 24 months from the date of purchase. Excluded are accessory items, rechargeable or disposable batteries that are delivered with the product; due to their characteristics these products have a shorter service life that is principally dependent on the individual frequency of use. For this reason, we recommend that the sales receipt be retained as proof of purchase. [. . . ]