User manual SENNHEISER EW300 G2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SENNHEISER EW300 G2. We hope that this SENNHEISER EW300 G2 user guide will be useful to you.


SENNHEISER EW300 G2 : Download the complete user guide (1698 Ko)

Manual abstract: user guide SENNHEISER EW300 G2

Detailed instructions for use are in the User's Guide.

[. . . ] W 300 Instructions for use Thank you for choosing Sennheiser! We have designed this product to give you reliable operation over many years. Over half a century of accumulated expertise in the design and manufacture of high-quality electro-acoustic equipment have made Sennheiser a world-leading company in this field. Please take a few moments to read these instructions carefully, as we want you to enjoy your new Sennheiser products quickly and to the fullest. 48 Contents The evolution wireless series ew 300 G2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 The channel bank system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] With the transmitters, the current setting that can be adjusted flashes on the display. With the receiver, the name of the menu and the current setting are displayed. Adjusting a setting Press the / buttons to adjust the setting. By briefly pressing the / buttons, the display jumps either forwards or backwards to the next setting. In the "Channel", "Tune" and "Name" menu, the / buttons feature a "fast search" function. The "fast search" function allows you to get fast and easily to your desired setting. With the transmitters, the new setting flashes on the display until it is stored. Storing a setting Press the SET button to store the setting. "Stored" appears on the display, indicating that the setting has been stored. With most menus, new settings become effective immediately without having to be stored. An exception are the "BANK", "CHAN", "TUNE" and "RESET" menus of the transmitters and the "Reset" menu of the receiver. With these menus, new settings only become effective after they have been stored and "Stored" had appeared on the display. 67 Exiting the operating menu Select the "Exit" menu to exit the operating menu and to return to the standard display. When you have entered the operating menu, the ON/OFF button or the ON button (EM 300 G2 receiver only) serves as the ESC (cancel) key, i. e. by briefly pressing the ON/OFF or POWER button, you cancel your entry and return to the standard display. 68 Operating menu of the receiver SET Exit Menu Exit Bank Channel SET 1 01 Bank 1. 01 B. CH 786. 300 MHz Bank 3. 01 B. CH / 790. 250 MHz Current channel bank : 1. . . 8, U (User Bank) Changing the channel bank SET: Stores the setting Stored Menu Bank 3 Channel 01 Tune 786. 400MHz Changing the channel SET Channel 3. 01 790. 250 MHz B. CH Current channel and corresponding frequency Channel 3. 08 807. 900 MHz B. CH / : Channel 01. . . 08 SET: Stores the setting Stored Menu Channel 08 Tune 807. 900MHz Scan Setting the frequency for channel bank "U" SET Tune U. 01 B. CH 786. 300 MHz Tune U. 01 B. CH 797. 075 MHz Current frequency on the selected channel / : Receiving frequency in steps of 25 kHz SET: Stores the setting Stored Menu Tune Scan AF Out SET Scan 797. 075MHz +18 Channel list Scan new Scan reset Channel list = Last scan result, Scan new = Starts a new scan, Scan reset = Deletes the last scan result SET Scan new SET = Starts a new scan SET Scan reset SET: Deletes the scan result and releases locked channels SET Scanning the channel banks for free channels Scan 1. 01 786. 300 MHz B. CH Scans all channel banks for free channels Bank 1 2 3 Free 08 08 03 Bank 5 6 7 Free 06 08 02 4 04 8U 01 08 Bank 1 2 3 Free 08 08 08 Bank 5 6 7 Free 08 08 08 4 08 8U 08 08 Number of free channels per channel bank / : Selects a channel bank SET: Changes to the "Channel" menu SET Bank 1 2 3 Free 02 08 02 Bank 5 6 7 Free 04 05 08 4 08 8U 03 08 / : Selects a channel bank SET: Changes to the "Channel" menu Channel 1. 03 790. 600 MHz B. CH Channel and corresponding frequency / : Channel 01. . . 08 SET: Stores the setting SET Number of free channels per channel bank / : Selects a channel bank SET: Changes to the "Channel" menu SET SET STORED Stored AF Out +18 69 Scan Menu Scan AF Out Squelch SET AF Out +18 Current audio output level AF Out ­24 / : +18 . . . 0. . . ­ 24 dB +18 High Setting the audio output level (in steps of 6 dB) SET: Stores the setting Stored Menu AF Out Squelch Display SET ­24 Low Squelch Low Current squelch threshold Squelch High / : Low, Mid, High Setting the squelch threshold SET: Stores the setting Stored Menu Squelch High Display Main Name VOCAL Switching between the standard displays SET Display Main Current standard display Display Frequency / : Main, Frequency, Bank/Channel, Name, AFMeter, Second RF SET: Stores the setting Stored Main Frequency Bank/Channel Name AF-Meter Second RF Menu Display Name Reset SET Frequency VOCAL Name OCAL Current receiver name Name G CAL / : Name (10 characters) Letters w/o pronounciation marks, numbers from 0. . . 9, special characters, spaces Assigning the receiver a name Stored SET: 9 x next character, then store Menu Name Reset Pilot SET GUITAR On Reset Reset?Yes / : No, Yes "reset"= Yes: SET: Receiver loads factorypreset default settings (only pilot tone setting is kept), receiver is restarted, standard display appears "reset"= No: SET: Reset is cancelled Loading the factory-preset default settings Pilot On/Off 70 Reset Menu Reset Pilot Lock SET Pilot On Pilot tone evaluation activated or deactivated Pilot Off / : On, Off SET: Stores the setting On Off Activating/deactivating the pilot tone evaluation STORED Menu Pilot Off Lock Off LCD Contr IIIIII. . . . . Activating the lock mode SET Lock Off Lock mode activated or deactivated Lock On / : On, Off Lock mode = On: SET: Stores the setting, returns to standard display STORED Lock mode = Off: SET: Stores the setting Menu Lock On LCD Contr IIIIII. . . . . Exit Adjusting the contrast of the graphic display SET LCD Contrast IIIIII. . . . . . . . . . Current contrast setting LCD Contrast IIIIIIIIII. . . . . . / : 16 steps SET: Stores the setting STORED Menu LCD Contr Exit Bank SET IIIIIIIIII. . . . . . 1 Exiting the operating menu Bank 1 71 Operating menu of the transmitters EXIT SET BANK Changing the channel bank SET BANK 1 Current channel bank BANK U / : 1. . . 8, U (User Bank) SET: Stores the setting STORED CHAN Changing the channel SET 1. 03 B. CH / 1. 02 : Channel B. CH Current channel (display depends on "DISPLY" setting) 01. . . 08 SET: Stores the setting STORED TUNE Setting the frequency for channel bank "U" SET 790. 025 MHz 791. 125 MHz Current frequency on the selected channel / : Transmission frequency in steps of 25 kHz STORED SENSIT Setting the sensitivity SET -10 dB Current sensitivity setting / -30 dB : SK 300 G2: 0. . . -30 dB SKM 300 G2: 0. . . -30 dB SET: Stores the setting STORED SET DISPLY Switching between the standard displays FREQ Current standard display / NAME : FREQ, NAME, CHAN SET: Stores the setting STORED NAME 72 DISPLY NAME Assigning the transmitter a name SET VOCAL Current transmitter name GUCAL /: Name (6 characters) Letters w/o pronounciation marks, numbers from 0. . . 9, special characters, spaces STORED SET: 5 x next character, then store RESET Loading the factorypreset default settings SET RST. OK : OK, NO "reset" = OK: SET: Transmitter loads factory-preset default settings (only pilot tone setting is kept), transmitter is restarted, standard display "reset" = NO SET: Reset is cancelled PILOT Activating/deactivating the pilot tone transmission SET PLT. OFF / : ON, OFF SET: Stores the setting STORED LOCK Activating the lock mode SET LOC. OFF OFF Lock mode activated or deactivated LOC. ON ON / : ON, OFF Lock mode = ON: SET: Stores the setting (STORED), returns to standard display STORED EXIT Exiting the operating menu SET Lock mode = OFF: SET: Stores the setting BANK 73 Adjustment tips for the operating menu Switching between channel banks BANK Bank Via the "Bank" menu, you can switch between the nine channel banks. The channel banks "1" to "8" have eight switchable channels that are factorypreset to a transmission/receiving frequency (see "The channel bank system" on page 50). The channel bank "U" (user bank) has eight switchable channels to store your selection out of 1440 transmission/receiving frequencies that are freely selectable within the preset frequency range. When switching from one channel bank to another, the channel with the lowest channel number is automatically displayed. If, during the last scan of this channel bank, an interfering frequency was detected on the channel with the lowest channel number (see "Scanning the channel banks for free channels (EM 300 G2 only)" on page 75), the receiver display panel automatically displays the next free channel. Switching between the channels in a channel bank CHAN Channel Via the "Channel" menu, you can switch between the eight channels in a channel bank. [. . . ] Ihre gesetzlichen Mängelansprüche aus dem Kaufvertrag gegen den Verkäufer werden durch diese Garantie nicht eingeschränkt. Die Garantie kann weltweit in allen Ländern ­ außer in den USA ­ in Anspruch genommen werden, in denen das jeweils nationale Recht unseren Garantiebestimmungen nicht entgegensteht ENGLISH The guarantee period for this Sennheiser product is 24 months from the date of purchase. Excluded are accessory items, rechargeable or disposable batteries that are delivered with the product; due to their characteristics these products have a shorter service life that is principally dependent on the individual frequency of use. For this reason, we recommend that the sales receipt be retained as proof of purchase. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SENNHEISER EW300 G2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SENNHEISER EW300 G2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.