User manual SENNHEISER EW 335 G3
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SENNHEISER EW 335 G3. We hope that this SENNHEISER EW 335 G3 user guide will be useful to you.
You may also download the following manuals related to this product:
SENNHEISER EW 335 G3 FICHE TECHNIQUE (103 ko)
SENNHEISER EW 335 G3 FREQUENCY SHEETS (633 ko)
SENNHEISER EW 335 G3 FREQUENCY SHEETS (633 ko)
SENNHEISER EW 335 G3 FREQUENCY SHEETS (633 ko)
SENNHEISER EW 335 G3 PRODUCT SHEET (142 ko)
SENNHEISER EW 335 G3 FREQUENCY SHEET (592 ko)
SENNHEISER EW 335 G3 FREQUENCY SHEETS (633 ko)
Manual abstract: user guide SENNHEISER EW 335 G3
Detailed instructions for use are in the User's Guide.
[. . . ] 300 Series
Instruction manual
Contents
Contents
Important safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Bodypack transmitter and radio microphone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The contacts can become dirty or damaged if touched.
When unscrewing the microphone head during operation, the muting function is automatically activated. When screwing the microphone head back to the radio microphone, the muting function is deactivated. Put the radio microphone back into operation.
Changing the color-coded protection ring
The color-coded protection ring ¾ prevents the multi-function switch ¹ from accidental operation. The protection rings allow you to clearly identify each radio microphone. Remove the color-coded protection ring as shown in the left-hand diagram. Put on a new protection ring as shown in the right-hand diagram.
¾
¾
º
º
Using the devices
To establish a transmission link, proceed as follows: 1. The transmission link is established and the and the display backlighting of the receiver changes from red to orange. If you cannot establish a transmission link between transmitter and receiver: Make sure that transmitter and receiver are set to the same frequency bank and to the same channel. If necessary, read the chapter "If a problem occurs . . . " on page 30.
17
Using the devices
It is vital to observe the following notes: Make sure that the desired frequencies are listed in the enclosed frequency information sheet. Make sure that the desired frequencies are approved and legal in your country and, if necessary, apply for an operating license.
Switching the devices on/off
EM 300 receiver
To switch the receiver on:
ew300 G3
200 MHz
SKM300
E
Briefly press the STANDBY button ¶. The receiver switches on and the "Receiver Parameters" standard display appears.
¶
To switch the receiver to standby mode: If necessary, deactivate the lock mode (see page 21). Keep the STANDBY button ¶ pressed until "OFF" appears on the display panel.
When in the operating menu, pressing the STANDBY button ¶ will cancel your entry (ESC function) and return you to the current standard display. To completely switch the receiver off: Disconnect the receiver from the mains by unplugging the mains unit from the wall socket.
SK 300 bodypack transmitter
´ ¹ ¹ ¸
To switch the bodypack transmitter on (online operation): Push the two catches ¹ and open the battery compartment cover ¸.
18
Using the devices Briefly press the ON/OFF button . The red ON LED ´ lights up and the standard display "Frequency/Name" appears on the display panel. You can switch the bodypack transmitter on and deactivate the RF signal on switchon. To switch the bodypack transmitter off: If necessary, deactivate the lock mode (see page 21).
ON/OFF
ON/OFF
Press the ON/OFF button until "OFF" appears on the display panel. When in the operating menu, pressing the ON/OFF button will cancel your entry (ESC function) and return you to the current standard display.
To switch the bodypack transmitter on and to deactivate the RF signal on switch-on (offline operation):
ON/OFF
Press the ON/OFF button
until "RF Mute On?" appears on the display panel.
SET
Press the SET button º. The transmission frequency is displayed but the bodypack transmitter does not transmit an RF signal. When the pilot tone function is activated on both bodypack transmitter and receiver, "RF Mute" appears on the receiver's display panel.
543. 200 MHz ew300 G3
AF
P MUTE
Use this function to save battery power or to prepare a bodypack transmitter for use during live operation without causing interference to existing transmission links. To activate the RF signal:
ON/OFF
SET
Briefly press the ON/OFF button . The transmission icon is displayed again.
19
Using the devices
SKM 300 radio microphone
µ
»
To switch the radio microphone on (online operation):
ON/OFF
Briefly press the ON/OFF button . The red ON LED µ lights up and the standard display "Frequency/Name" appears on the display panel. [. . . ] 980 g
Overall device
Temperature range Power supply Current consumption Dimensions Weight
32
Specifications
In compliance with (EM)
Europe: EMC Radio Safety EN 301489-1/-9 EN 300422-1/-2 EN 60065
USA:
47 CFR 15 subpart B
Approved by
Canada: Industry Canada RSS 210, IC: 2099A-G3SKMEM
Mains unit
Input voltage Power/current consumption Output voltage Secondary output current Temperature range 100 to 240 V~, 50/60 Hz max. 120 mA 12 V 400 mA 10°C to +40°C
In compliance with
Europe: EN 55022, EN 55024, EN 55014-1/-2 Safety EN 60065 47 CFR 15 subpart B ICES 003 EMC
USA: Canada: Certified by cCSAus KL, 60065, CSA.
For accessories and information on connector assignment, visit the ew G3 product page at www. sennheiser. com.
SK 300 and SKM 300
RF characteristics
Modulation Frequency ranges Transmission frequencies wideband FM 516558, 566608, 626668, 734776, 780822, 823865 MHz (A to E, G, see page 4) 1, 680 frequencies, tuneable in steps of 25 kHz 20 frequency banks, each with up to 24 factory-preset channels, intermodulation-free 6 frequency banks, each with up to 24 user programmable channels 42 MHz ±24 kHz / ±48 kHz ±15 ppm typ. 10/30 mW, switchable can be switched off
Switching bandwidth Nominal/peak deviation Frequency stability RF output power at 50 Pilot tone squelch
33
Specifications
AF characteristics
Compander system AF frequency response SK SKM S/N ratio (1 mV, peak deviation) THD Max. input voltage (SK) microphone/line Input impedance (SK) microphone/line Adjustment range of input sensitivity Sennheiser HDX microphone: 8018, 000 Hz line: 2518, 000 Hz 8018, 000 Hz 115 dBA 0. 9% 3 Vrms 40 k, unbalanced/1 M SK: 60 dB, adjustable in steps of 3 dB SKM: 48 dB, adjustable in steps of 6 dB 10°C to +55°C 2 AA size batteries, 1. 5 V or BA 2015 accupack 2. 4 V typ. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SENNHEISER EW 335 G3