User manual SENNHEISER EW 322 G2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SENNHEISER EW 322 G2. We hope that this SENNHEISER EW 322 G2 user guide will be useful to you.


SENNHEISER EW 322 G2 : Download the complete user guide (1789 Ko)

You may also download the following manuals related to this product:

   SENNHEISER EW 322 G2 (1646 ko)
   SENNHEISER EW 322 G2 FICHE TECHNIQUE (46 ko)
   SENNHEISER EW 322 G2 PRODUCT SHEET (351 ko)
   SENNHEISER EW 322 G2 FREQUENCY SHEETS (36 ko)

Manual abstract: user guide SENNHEISER EW 322 G2

Detailed instructions for use are in the User's Guide.

[. . . ] W 300 Instructions for use Thank you for choosing Sennheiser! We have designed this product to give you reliable operation over many years. Over sixty years of accumulated expertise in the design and manufacture of high-quality electro-acoustic equipment have made Sennheiser a world-leading company in this field. Please take a few moments to read these instructions carefully, as we want you to enjoy your new Sennheiser products quickly and to the fullest. 2 Contents The evolution wireless series ew 300 G2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 The channel bank system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The "MUTE" display appears on the transmitter display panel. Provided that the pilot tone function is activated on both the transmitter and the receiver, the "MUTE" display also appears on the receiver display panel. Set the MUTE switch back to the original position to retransmit the audio signal. Muting the SKM 300 G2 radiomicrophone Turn the protective cap ¶ at the bottom of the radiomicrophone so that the MUTE switch becomes accessible. The "MUTE" display appears on the transmitter display panel. Provided that the pilot tone function is activated on both the transmitter and the receiver, the "MUTE" display also appears on the receiver display panel. Set the MUTE switch back to the original position to retransmit the audio signal. ¶ Activating/deactivating the lock mode ew 300 G2 transmitters and receivers have a lock mode that can be activated or deactivated via the operating menu (see "Activating/deactivating the lock mode" on page 34). The lock mode prevents that the transmitter or receiver is accidentally programmed or switched off during operation. 19 The operating menu A special feature of the Sennheiser ew 300 G2 series is the similar, intuitive operation. As a result, the units are easy to operate and adjustments to the settings can be made quickly and "without looking" ­ even in stressful situations, for example on stage or during a live show or presentation. The buttons Buttons ON/OFF or ON (EM 300 G2 only) SET Mode Standard display Operating menu Setting mode Standard display Operating menu Setting mode / Standard display Operating menu Setting mode To . . . turn the transmitter or receiver on and off cancel the entry and return to the standard display cancel the entry and return to the standard display get into the operating menu get into the setting mode of the selected menu store the settings and return to the previous menu level without function change to the previous menu ( ) or change to the next menu () adjust the setting of the selected menu: option ( / ) Overview of menus Receiver Display Bank Channel Tune Function of the menu Switching between channel banks Switching between the channels in a channel bank Setting a receiving frequency for the channel bank "U" (user bank) Display BANK CHAN TUNE SENSIT Transmitters Function of the menu Switching between channel banks Switching between the channels in a channel bank Setting a transmission frequency for the channel bank "U" (user bank) Adjusting the sensitivity (AF) Scan AF Out Squelch Display Name Reset Pilot Lock LCD Contr Exit Scanning the channel banks for free channels Adjusting the audio output level Adjusting the squelch threshold Selecting the standard display Entering a name Activating/deactivating the pilot tone evaluation Activating/deactivating the lock mode Adjusting the contrast of the graphic display Exiting the operating menu and returning to the standard display DISPLY NAME PILOT LOCK Selecting the standard display Entering a name Loading the factory-preset default settings Activating/deactivating the pilot tone transmission Activating/deactivating the lock mode Loading the factory-preset default settings RESET EXIT Exiting the operating menu and returning to the standard display 20 Working with the operating menu By way of example of the "Tune" menu, this section describes how to use the operating menu. After switching the unit on, the standard display is shown on the display panel. EM 300 G2 Transmitters Getting into the operating menu Press the SET button to get from the standard display into the operating menu. With the receiver, the current setting is additionally displayed. Selecting a menu Press the / buttons to select a menu. Press the SET button to get into the setting mode of the selected menu. With the transmitters, the current setting that can be adjusted flashes on the display. With the receiver, the name of the menu and the current setting are displayed. Adjusting a setting Press the / buttons to adjust the setting. By briefly pressing the / buttons, the display jumps either forwards or backwards to the next setting. In the "Channel", "Tune" and "Name" menu, the / buttons feature a "fast search" function. The "fast search" function allows you to get fast and easily to your desired setting. With the transmitters, the new setting flashes on the display until it is stored. Storing a setting Press the SET button to store the setting. "Stored" appears on the display, indicating that the setting has been stored. With most menus, new settings become effective immediately without having to be stored. An exception are the "BANK", "CHAN", "TUNE" and "RESET" menus of the transmitters and the "Reset" menu of the receiver. With these menus, new settings only become effective after they have been stored and "Stored" had appeared on the display. 21 Exiting the operating menu Select the "Exit" menu to exit the operating menu and to return to the standard display. When you have entered the operating menu, the ON/OFF button or the ON button (EM 300 G2 receiver only) serves as the ESC (cancel) key, i. e. [. . . ] 30 mW SKM 300 G2 Microphone Line Microphone Line 1. 8 Vrms, unbalanced 2. 4 Vrms 10 k, unbalanced 1 M ­ ­ ­ ­ Overall device Power supply Nominal voltage Max. power consumption at nominal voltage Power consumption with switched-off transmitter Operating time (with batteries) Operating time (with BA 2015 accupack) Dimensions [mm] Weight (incl. batteries) Microphones Transducer principle Sensitivity Pick-up pattern Max. SPL Microphone heads Transducer principle Sensitivity Pick-up pattern Max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SENNHEISER EW 322 G2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SENNHEISER EW 322 G2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.