User manual SENNHEISER EM 3731

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SENNHEISER EM 3731. We hope that this SENNHEISER EM 3731 user guide will be useful to you.


SENNHEISER EM 3731 : Download the complete user guide (3826 Ko)

You may also download the following manuals related to this product:

   SENNHEISER EM 3731 (3841 ko)
   SENNHEISER EM 3731 (3865 ko)
   SENNHEISER EM 3731 (3728 ko)
   SENNHEISER EM 3731 01-08 (3728 ko)
   SENNHEISER EM 3731 01-08 (3865 ko)
   SENNHEISER EM 3731 FREQUENCY TABLES (69 ko)
   SENNHEISER EM 3731 FREQUENCY TABLES (69 ko)
   SENNHEISER EM 3731 FREQUENCY TABLES (69 ko)
   SENNHEISER EM 3731 FREQUENCY TABLES (69 ko)
   SENNHEISER EM 3731 FREQUENCY TABLES (69 ko)
   SENNHEISER EM 3731 FREQUENCY TABLES (69 ko)

Manual abstract: user guide SENNHEISER EM 3731

Detailed instructions for use are in the User's Guide.

[. . . ] EM 3731 EM 3732 EM 3732 Command Instructions for use A RF 300 100 30 B PEAK 100 50 10 % DEV µV 10 790. 800 03. 03 BANK CH M H z A RF 300 100 B PEAK 100 50 10 % DEV AF COM 30 µV 10 790. 800 03. 03 BANK CH M H z AF COM Contents Contents Important safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Delivery includes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 The EM 3731/3732 receiver family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 The frequency bank system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Connect headphones with a ¼" (6. 3 mm) stereo jack plug to the headphone output 2. To monitor the audio signals of one of the two receivers of a twin receiver: A RF 300 100 30 10 B % DEV PEAK 100 50 10 V 790. 800 03. 03 BANK CH M H z save AF COM sync esc Press the headphone button 0 of the receiver whose audio signals you want to monitor. To simultaneously monitor the audio signals of both receivers of a twin receiver: Simultaneously press the headphone buttons 0 of both receivers. The audio signals of the left receiver are output via the left headphone channel, the audio signals of the right receiver are output via the right headphone channel. To switch the headphone output off: Press the headphone button 0 of the receiver whose headphone output you want to switch off. Deactivating the lock mode When the receivers are remote controlled via a PC and the supplied "Wireless Systems Manager" software, their buttons can be locked via the "Wireless Systems Manager" software. To deactivate the lock mode: Press the esc button 6 until the progress bar is complete and the status display appears. The lock mode is deactivated and the settings can be made manually. Hold esc to unlock 20 Using the receiver Synchronizing the transmitter with the receiver frequency Via its infra-red interface, the receiver can transfer the frequency and the name to suitable transmitters (e. g. Note: The transmitter must be from the same frequency range ("A" to "I", see page 5) and be equipped with the same compander system (HDP, see page 38) as the receiver!Set the receiver to the desired receiving frequency (see "Setting the receiving frequency" on page 28 and "Selecting a frequency bank and a channel" on page 28) and enter the desired name (see "Entering a name" on page 29). EV 790. 800 03. 03 BANK CH M H z save AF COM digital audio processing sync esc sync Press the sync button 9. The two blue LEDs in the infra-red interface (sync) A flash and the backlighting of the sync button 9 flashes red. During the transfer, the two blue LEDs in the infra-red interface (sync) A flash and the backlighting of the sync button 9 flashes green. ­ After successful completion of the synchronization, the two blue LEDs in the infra-red interface (sync) A stop flashing and the sync button 9 is backlit in green. The receiver's frequency and name are now also set on the transmitter and the transmission link is ready for operation. the transmitter is too far away from the receiver), the two blue LEDs in the infra-red interface (sync) A stop flashing and the sync button 9 is backlit in red. Note on the SKM 5200 hand-held transmitter: The infra-red interface of the SKM 5200 hand-held transmitter is located at the left-hand margin of the display. Position the transmitter's infra-red interface precisely in front of the infra-red interface (sync) A of the receiver. save sync esc digital audio processing A RF 300 100 30 B PEA % 10 5 1 sync V 10 < 5cm SKM 5200 21 The operating menu The operating menu Overview of menus Menu level Display Tune Function of the menu Setting a receiving frequency (this frequency is automatically stored in channel "01" of the frequency bank "U" (user bank)). Switching between the frequency banks and Bank. Ch between the channels of a frequency bank Name Entering a name Squelch Adjusting the squelch threshold Booster Switching the booster supply voltage on/off AF Out Adjusting the audio output level Adjusting the sampling rate of the digital audio Clock output (EM 3732 Command receiver only) Command Configuring the audio and command outputs More Changing to the extended menu Scan Scanning the frequency banks for free frequencies Display Selecting the status display IP-Addr Adjusting the IP address of the receiver MAC Displaying the MAC address Standby Setting the receiver to standby mode Reset Loading the factory-preset default settings 22 Extended menu Uppermost menu level The operating menu Working with the operating menu By way of example of the "Tune" menu, this section describes how to use the operating menu. 790. 800 03. 03 BANK CH M H z After switching the receiver on, the status display is shown on the display panel. AF COM Getting into the operating menu 790. The "Tune" menu is displayed together with its current setting. The position of a menu within the operating menu is illustrated by a graphic in the upper display margin (the "Tune" menu is on the very left of the operating menu). 800 MHz Tune B. Ch 1. 01 Bank Turn the jog dial 7 until the icon of the desired menu is in the center of the display. Press the jog dial 7 to get into the setting mode of the selected menu. The icon of the menu is displayed and the current setting starts flashing. Depending on the selected menu, it is possible that the next setting that can be changed and confirmed by turning and pressing the jog dial 7 can start flashing. [. . . ] input voltage 15 V (DC + AC) 75 , transformer balanced, AC-coupled output voltage 2. 5 V± 250 mV at 75 source impedance EMC Radio Safety 47 CFR 15 Industry Canada EN 301489-1/-9 EN 300422-1/-2 EN 60065 subpart B RSS 210, IC: 2099A-EM 373x Mains connector Dimensions W x D x H [mm] Weight Booster supply Ethernet Digital output Word clock connection Accepted sampling rates Word clock input impedance Word clock output impedance In compliance with Type approval 42 Accessories/spare parts Accessories/spare parts The following accessories are available from your authorized dealer: Cat. 502195 502197 502196 500887 004645 003658 009423 009407 009408 Accessory A 3700 active broadband antenna AD 3700 active broadband directional antennna AB 3700 antenna booster A 5000 CP circularly polarized broadband antenna A 1031 broadband remote antenna A 2003 broadband directional antenna ASA 3000-EU antenna splitter ASA 3000-US antenna splitter ASA 3000-UK antenna splitter 002325 002326 502432 002324 Cat. 004368 087969 087972 Accessory GA 3030 AM antenna mount Antenna daisy chain cable, 50 , BNC, 0. 25 m Word clock daisy chain cable, 75 , BNC, 0. 25 m GZL AES 10 AES3 cable, 10 m, 110 , double-shielded GZL 1019-A1 coaxial cable, type RG 58, BNC to BNC, 1 m GZL 1019-A5 coaxial cable, type RG 58, BNC to BNC, 5 m GZL 1019-A10 coaxial cable, type RG 58, BNC to BNC, 10 m 43 Manufacturer Declarations Manufacturer Declarations Warranty regulations The guarantee period for this Sennheiser product is 24 months from the date of purchase. Excluded are accessory items, rechargeable or disposable batteries that are delivered with the product; due to their characteristics these products have a shorter service life that is principally dependent on the individual frequency of use. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SENNHEISER EM 3731




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SENNHEISER EM 3731 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.