Detailed instructions for use are in the User's Guide.
[. . . ] W 300 IEM
Instructions for use
.
Thank you for choosing Sennheiser!
We have designed this product to give you reliable operation over many years. Over half a century of accumulated expertise in the design and manufacture of high-quality electro-acoustic equipment have made Sennheiser a world-leading company in this field. Please take a few moments to read these instructions carefully, as we want you to enjoy your new Sennheiser products quickly and to the fullest.
40
Contents
The ew 300 IEM G2 system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
The channel bank system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Mode Stereo
Adjusting the contrast of the graphic display
SET
LCD Contrast IIIIII. . . . . . . . . .
Current contrast setting
LCD Contrast IIIIIIIIII. . . . . .
/ :
16 steps
SET: Stores the setting
STORED
SET
Menu LCD Contr IIIIIIIIII. . . . . . Mode Stereo Lock Off
Switching between stereo and mono operation
Mode Stereo
Current setting
Mode Mono
/ : Stereo, Mono
SET: Stores the setting
STORED Menu Mode Lock Exit
SET
Mono Off
Lock Off
Lock mode activated or deactivated
Lock On
/ : On, Off Lock mode = On: SET: Stores the setting, returns to standard display
Activating the lock mode
STORED
Lock mode = Off: SET: Stores the setting
Menu Lock Exit Bank
SET
On 3
Exiting the operating menu
Bank
3
58
Operating menu of the stereo receiver
EXIT
SET
BANK
Changing the channel bank
SET
BANK 1
Current channel bank
/
BANK U
: 1. . . 8, U (User
Bank) SET: Stores the setting
STORED CHAN
Changing the channel SET
1. 01
B. CH
/
1. 12
: Channel
B. CH
Current channel or frequency
01. . . 12
SET: Stores the setting
STORED TUNE
Setting the frequency for channel bank "U" SET
790. 025 MHz
Current frequency on the selected channel
/
791. 125 MHz
: Receiving frequency in steps of 25 kHz
SET: Stores the setting
STORED SCAN
Scanning the selected channel bank for free channels SET U.
START
U.
/
CLEAR
: CLEAR, START
09 CH FREE
SET
Start scan = START SET: Scans the selected channel bank for free channels Delete result = CLEAR SET: Releases locked channels
STORED SQELCH
Setting the squelch threshold SET
SQ LO
Current squelch threshold
/
SQ HI
:
LO, MID, HI
SET: Stores the setting
STORED ST--FOC
59
SQELCH
ST--FOC
Switching between stereo and FOCUS operation
SET
STEREO
Current setting
/
FOCUS
:
Stereo, Focus
SET: Stores the setting
STORED
SET
LTD
Limiting the volume at the headphone output
LTD. OFF OFF
Limiter activated or deactivated
/
LTD. ON
: OFF, ON SET: Stores the setting
STORED HI--BST
Boosting the AF frequency response SET
HB. OFF OFF
Frequency boost activated or deactivated
/
HB. ON
: OFF, ON
SET: Stores the setting
STORED DISPLY
Switching between the standard displays SET
CHAN
Current standard display
NAME
/ : FREQ, NAME, CHAN
SET: Stores the setting
STORED NAME
Assigning the receiver a name SET
VOCAL
Current receiver name
/
GUCAL
: Enter a name (6 characters) Letters w/o
pronounciation marks, numbers from 0. . . 9, special characters, spaces
STORED RESET
SET: 5 x next character, then store
60
NAME
SET
RESET
Loading the factorypreset default settings
RST. OK
/ : OK, NO "reset" = OK: SET: Receiver loads factory-
preset default settings (only pilot tone setting is kept), receiver is restarted, standard display appears
"reset" = NO SET: Reset is cancelled SET
PILOT
Activating/deactivating the pilot tone transmission
PLT. OFF
/ : ON, OFF
SET: Stores the setting
STORED LOCK
Activating the lock mode SET
LOC. OFF OFF
Lock mode activated or deactivated
LOC. ON
/ : ON, OFF
STORED EXIT
Exiting the operation SET
Lock mode = ON: SET: Stores the setting, ("STORED") returns to standard display Lock mode = OFF: SET: Stores the setting
BANK
BAL. L 1
Current balance setting Adjusting the balance
BAL. R 15
: BAL. L 1. . . 15, BAL. --0--, BAL. R 1. . . 15 /
61
Adjustment tips for the operating menu
Switching between channel banks BANK Bank
Via the "Bank" menu, you can switch between the nine channel banks of the ew 300 IEM G2 transmitter and receiver. The channel banks "1" to "8" have up to 12 switchable channels that are factory-preset to a transmission/ receiving frequency (see "The channel bank system" on page 42). The channel bank "U" (user bank) also has up to 12 switchable channels to store your selection out of 1440 transmission/receiving frequencies that are freely selectable within the preset frequency range. When switching from one channel bank to another, the channel with the lowest channel number is automatically displayed. If, during the last scan of this channel bank, an interfering frequency was detected on the channel with the lowest channel number, the receiver display panel automatically displays the next free channel (see below).
Switching between the channels in a channel bank CHAN Channel
Via the "Channel" menu, you can switch between the channels in a channel bank. Always set the transmitter and the receiver of a transmission link to the same channel. After scanning a channel bank (see "Scanning the channel banks for free channels (receiver only)" on page 62), only the free channels are displayed. Set the transmitter to one of the free channels
Selecting the frequencies to be stored in the channel bank "U" TUNE Tune
Via the "Tune" menu, you can select the frequencies to be stored in the channel bank "U" (user bank). When you have selected one of the channel banks "1" to "8" and then select the "Tune" menu, the transmitter or receiver automatically switches to channel 01 of the channel bank "U". Use the / buttons to select the desired transmission or receiving frequency. Transmission and receiving frequencies are tunable in 25-kHz steps within a switching bandwidth of 36 MHz max. For intermodulationfree frequencies, please refer to the enclosed frequency table.
Scanning the channel banks for free channels (receiver only) SCAN
Before putting one or several transmission links into operation, you should scan the selected channel bank for free channels.
62
Starting the scan and storing the scan result Before starting the scan, switch all transmitters of your system off, since channels used by switched-on transmitters will not be displayed as "free channels". Select "START" and confirm your selection by pressing the SET button. After the scan is completed, the number of free channels is displayed. Pressing the SET button once more will store the scan result and lock all channels that are used or subject to interference. Select "CLEAR" and confirm your selection by pressing the SET button. [. . . ] Las pretensiones legales por defectos y emanadas del contrato de compraventa frente al vendedor, no quedan limitadas por esta garantia. La garantia esta disponible en todos los paises a excepción de EE. UU. , siempre que la legislación nacional aplicable no sea contraria a nuestras determinaciones de garantia.
NEDERLANDS
Wij hanteren voor onze producten een garantietermijn gedurende een periode van 24 maanden. Uitgezonderd hiervan zijn accessoires, accu's en batterijen die aan het product toegevoegd zijn; op grond van hun geaardheid beschikken deze producten over een kortere levensduur die van geval tot geval van hun gebruiksintensiteit afhangt. Zonder dit bewijs, dat door de Sennheiser servicepartner wordt gecontroleerd, worden reparaties in principe tegen kostenvergoeding uitgevoerd. [. . . ]