User manual SAUNIER DUVAL XEON 30 HE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SAUNIER DUVAL XEON 30 HE. We hope that this SAUNIER DUVAL XEON 30 HE user guide will be useful to you.


SAUNIER DUVAL XEON 30 HE : Download the complete user guide (4773 Ko)

Manual abstract: user guide SAUNIER DUVAL XEON 30 HE

Detailed instructions for use are in the User's Guide.

[. . . ] High Efficiency Condensing Boiler Instructions for use Installation and servicing Xeon 18 HE Xeon 30 HE G. C. 41-920-46 Guarantee Registration Thank you for installing a new Saunier Duval appliance in your home. Saunier Duval appliances are manufactured to the very highest standard so we are pleased to offer our customers a Comprehensive Guarantee. This product is guaranteed for 24 months from the date of installation or 30 months from the date of manufacture, whichever is the shorter, for parts. [. . . ] Standard: Separate the flue duct from the terminal by twisting to release the terminal catch, then pull out of the retaining seal, refer to diagram 8. 8. The air duct should be cut at the opposite end to the terminal fixing. The terminal plastic duct MUST be cut at the opposite end to the catch. The plastic flue duct extensions MUST be cut at the opposite end to seal. Note: If you require to lubricate the seals to ease installation, please do not use a mineral oil based grease, we would recommend the use of water. Push the flue assembly into the wall, externally or internally, initially until the end of the assembly protrudes a short way from the inside face of the wall. This will enable the internal trim ring (if required) to be positioned and allow the flue duct to be drawn back into the flue elbow after the boiler has been mounted. 8. 4 Flue Attachment To Boiler Secure the flue elbow in position on top of the boiler with four torque headed screws supplied. Draw the flue assembly from wall and engage the flue duct into the elbow and butt fit the air duct, then fit the collar and secure with screws provided, see diagram 8. 9. NOTE: If the air and flue ducts have been correctly cut to the instructions given in section 8. 2, the rubber sealing collar should fit flush with the outside wall, check this. Slide the internal trim ring back against the wall, securing in place with a small amount of sealant if required. 8. 3 Flue Assembly The flue assembly is a push fit design with securing collars. Having adjusted the telescopic or cut the air and flue ducts as described in section 8. 2 Assemble the flue elbow to the air duct, ensuring the correct alignment of the terminal. Fit the collar into position, mark through two of the pre drilled holes in the collar. Remove collar and drill two 3mm diameter holes in the elbow, take care not to pierce the inner flue duct. Insert the terminal flue duct, remembering to engage the catch within the terminal, check for alignment. Fit the rubber sealing collar behind the locating lugs on the flue terminal, see diagram 8. 1. AIR DUCT TELESCOPIC Air duct securing telescopic Diagram 8. 7 28 12754 13mm AIR DUCT L L FLUE DUCT TERMINAL CATCH L + 11mm Diagram 8. 9 12756 Diagram 8. 8 12755 29 for qualified gas installers Installation and servicing instructions strictly reserved ELECTRICAL CONNECTIONS WARNING: This boiler must be earthed. Any fault arising from incorrect wiring cannot be put right under the terms of the Saunier Duval guarantee. Electrical components have been tested to meet the equivalent requirements of the BEAB. Connection of the whole electrical system and any heating system controls to the electrical supply must be through a common isolator. Isolation should preferably be by a double pole switched fused spur box having a minimum contact separation of 3mm on each pole. The fused spur box should be readily accessible and preferably adjacent to the boiler. A fused three pin plug and shuttered socket outlet may be used instead of a fused spur box provided that: a) They are not used in a room containing a fixed bath or shower. The mains electrical supply must be maintained at all times in order to provide domestic hot water. To gain access to the connection box remove the two retaining screws indicated in Diagram 9. 1 and carefully lower and pull forward the box to reveal the terminal strip inside. Connect both the mains supply and switched live from the external controls (room thermostat and, if applicable, frost thermostat) into the marked terminals as shown in diagrams 9. 2 and 9. 3. [. . . ] Lift up and carefully remove the condense trap taking care not to spill any water which may be left in the unit. Check for any debris in the outlet pipe of the condensate drain and clean as necessary. When refitting the float, take care as it can be fitted the wrong way. When refitting the cap ensure that a watertight seal is achieved, but do not use excessive force. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SAUNIER DUVAL XEON 30 HE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SAUNIER DUVAL XEON 30 HE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.