User manual SAMSUNG RD080HRXGB

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SAMSUNG RD080HRXGB. We hope that this SAMSUNG RD080HRXGB user guide will be useful to you.


SAMSUNG RD080HRXGB : Download the complete user guide (12166 Ko)

Manual abstract: user guide SAMSUNG RD080HRXGB

Detailed instructions for use are in the User's Guide.

[. . . ] DVM PLUS IV RDHHXG Series RDHRXG Series Air Conditioner installation manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www. samsung. com/register E S F I P D G Ne Po Hu R DB98-33140A(3) safety information SAFETY INFORMATION Before installing an air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently install a new appliance. DVM PLUS IV air conditioner uses R410A refrigerant. - When using R410A, moisture or foreign substances may affect the capacity and reliability of the product. Safety precautions must be taken when installing the refrigerant pipe. [. . . ] M · emoveallburrsattheedgeoftheknock-outholeandapplythepaintsittoprevent R rust. · seacabletubeandbushingtopreventacablefrombeingdamagedwhenpassing U through a knock-out hole. Knock-out hole installing the unit _23 installing the unit REFRIGERANT PIPING WORKS Connecting the outdoor unit pipe HeatPump Connectionfromfrontside Connectionfrombottomatthe left/rightside · irst, removethecoverfromunit. F · eparatetheknock-outholeatthe S · eparatetheknock-outholetouse. S bottom side of the unit and install If the hole is open, small animals such as the pipe. squirrels and rats may get into the unit · fterinstallingandinsulatingthepipe, A Workingprocess through the hole and the unit may be close up the remaining gap. remain open, small animals such as rats · ixthepipecoverofbottomsideandfix and squirrels may get inside the unit and F the pipe cover of upper side thereafter. cause damage to the unit. Single installation Gas side pipe Liquid side pipe Gas side pipe Liquid side pipe Combination installation Gas side pipe Oil balancing valve Liquid side pipe Gas side pipe Oil balancing valve Liquid side pipe 24_ installing the unit HeatRecovery Connectionfromfrontside Connectionfrombottomatthe left/rightside Single installation Gas pipe Liquid pipe Oil balancing valve High pressure gas pipe Gas pipe Liquid pipe Oil balancing valve High pressure gas pipe ENGLISH Gas pipe Gas pipe Oil balancing valve High pressure gas pipe Liquid pipe Oil balancing pipe Oil balancing valve High pressure gas pipe Combination installation Liquid pipe Oil balance pipe Caution for connecting the pipe CAUTION · hen connecting the pipe to the unit, the unit may get W damaged by a welding fire and a flame. Use a flame proofing cloth to protect the unit from a welding fire or flame. Ambient air temperature sensor for detecting outside temperature is located on the left side of the welding part. · he O-ring and Teflon packing inside service valve may get T damaged by a welding fire. Wrap the bottom side of the service valve with a wet cloth and weld it as shown above. Make sure not to interrupt the welding with the drops of the wet cloth. · he connecting pipes of liquid side and gas side should not T contact each other. Vibration may cause a damage to the pipes. Service valve Filling port Wet towel Temperature sensor installing the unit _25 installing the unit REFRIGERANT PIPING WORKS Piping works among outdoor units · The additional branch joints are needed for module installation of the outdoor units. · When outdoor units are installed in module, there is no designation of outdoor unit's location according to capacity. · The connected piping should be positioned at the same level with pipe cover hole or lower. Note the changes of DVM PLUS III, IV by comparing to DVM PLUS II Cautions Correctpipingwork Wrongpipingwork The refrigerant piping should be the same level or lower than connecting position of piping to outdoor units. Piping work should be run with side direction for better uniform distribution of refrigerant and oil like next diagram. Outdoor joint kits should be installed in a horizontal direction, even it is a low pressure pipe. Horizontal length = over 100mm Minimum 100mm When the piping length between outdoor and branch joints is 2m or more, a vertical trap has to be installed like right diagram. 200~300mm Less than 1m 2m or over 2m or over 26_ installing the unit The examples of the refrigerant pipe installation HeatPumpmodel ExampleofpipinglayoutsforDVMPLUSIV ENGLISH Using Y- joint Using Header joint Do not use Y-joint between Header joint and indoor units. HeatRecoverymodel Exampleofpipinglayouts MCU MCU MCU Using Y- joint MCU MCU MCU installing the unit _27 installing the unit REFRIGERANT PIPING WORKS Piping examples HeatPumpmodel BranchwithY-joint One outdoor unit installed b a h c i d j e k l f g m p a n b c d e f g h i BranchwithYandHeaderjoint BranchwithHeaderjoint F G Multiple outdoor units installed b a h c i d j e k l f F g m G n p Items Piping (Equivalent piping) Max. piping length Outdoor ~ Indoor unit Total piping 1000m below Branch with Y-joint 200m below (220m below) Examples Branch with Y-joint and Header joint Branch with header joint Branch with Y-joint Branch with Y-joint and Header joint Branch with Header joint r 10, s 10, t 10m r 13, s 13, t 13m H1 110m/40m H2 15m H3 5m b+c+d+e+f+g+p 45m, i 45m It needs to satisfy required conditions a+b+c+d+e+f+g+p 200m (220m) a+i+k 200m (220m) a+b+h 200m (220m) a+i 200m (220m) a+b+c+d+e+f+g+p+h+i+j+k+l+m+n 1000m a+b+c+d+e+f+g+p+h+i+j+k 1000m a+b+c+d+e+f+g+p+h+i 1000m Remarks Equivalent pipe length Y-joint : 0. 5m, Header : 1m Outdoor ~ Outdoor unit Piping Equivalent piping 10m below 13m below 110m / 40m*2) 15m below 15m below 45m below 90m below *1) Level difference Outdoor ~ Piping Indoor unit Indoor ~ Indoor Piping unit Outdoor ~ Piping Outdoor unit The first branch Allowable ~ length after Piping the farthest branch indoor unit Only apply to DVM PLUS IV (DVM PLUS IV HR exclusion) Distributionkit From distribution kit to indoor unit Allowable From distribution kit to indoor unit 3m Model MEV-A13SA / MEV-A16SA ( For 1 indoor unit) MXD-A13K116A / MXD-A13K200A / MXD-A16K200A / MXD-A22K200A ( For 2 indoor units) 20m MXD-A13K216A / MXD-A13K300A / MXD-A16K213A / MXD-A16K300A ( For 3 indoor units) Remarks For wall-mounted & ceiling indoor unit *1) Required condition Requiredcondition The first branch joint ~ If the sum of pipe length (b+c+d+e+f+g+p) is over 45m, (but not exceed : 90m) the farthest indoor unit Increase pipe size of b, c, d, e, f, g. (b, c, d, e, f, g : pipe 1 size up) If main pipe size is not increased, a+bx2+cx2+dx2+ex2+fx2+gx2+h+i+j+k+l+m+n+p 1000m Total pipe length size If main pipe size is increased, ax2+bx2+cx2+dx2+ex2+fx2+gx2+h+i+j+k+l+m+n+p 1000m Each Y-joint ~ h, i, j, . . . p 45m each indoor The difference between the distance of the outdoor unit to the farthest indoor Between indoor unit and the distance of the outdoor unit to the nearest indoor unit 45m units (a+b+c+d+e+f+g+p) - (a+h) 45m Example 28_ installing the unit *2) As an outdoor unit is located in a lower position than indoor unit, level difference is 40m. If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (If the level difference is higher than 50m, make a decision simulating by PDM kit installation Guide software whether the PDM kit should be installed or not. ) *PDM kit: Pressure Drop Modulation kit The refrigerant amount of the system must be less than 100kg. HeatRecoverymodel BranchwithY-joint Using MCU only ENGLISH MCU Using Y- joint and MCU MCU Items Piping (Equivalent piping) Max. piping length Outdoor ~ Outdoor unit 200m below (220m below) Using MCU only Examples a+b+c+d+e+f+g 200m (220m) a+g+m 200m (220m) a+b+c+d+e+f+g 1000m a+b+c+d+e+f+g+p+h+i+j+k+m 1000m Remarks Equivalent pipe length. [. . . ] · rotectionsystemcutspowerofthePCBforovervoltagewhenNphaseiscrosswiredtothe P R, S, and T. Check the power connection from N phase if the PCB is not turned on. completing the installation and commissioning _57 completing the installation and commissioning COMPLETING THE INSTALLATION · heckthefollowingaftertheinstallationiscompleted. C Outdoorunit ·Istheplacewell-ventilatedandensuresspaceforservice?·Isthereanypossibilityofshortcircuit? ·Checktheexternalsurfaceandtheinsideoftheindoorunit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG RD080HRXGB




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SAMSUNG RD080HRXGB will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.