[. . . ] SAFETY PRECAUTIONS
The following check should be performed for the continued protection of the customer and service technician.
ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER.
LEAKAGE CURRENT CHECK
Measure leakage current to a known earth ground (water pipe, conduit, etc. ) by connecting a leakage current tester such as Simpson Model 229-2 or equivalent between the earth ground and all exposed metal parts of the appliance (input/output terminals, screwheads, metal overlays, control shaft, etc. ). Plug the AC line cord of the appliance directly into a 120V AC 60Hz outlet and turn the AC power switch on. PRODUCT SAFETY NOTICE
Many electrical and mechanical parts in the appliance have special safety related characteristics. These are often not evident from visual inspection nor the protection afforded by them necessarily can be obtained by using replacement components rated for voltage, wattage, etc. [. . . ] To select a recording source component, press the REC SELECTOR switch so that the indicator of the desired source component lights up. When this switch is set to [TUNER] or [CD], the signal from the selected component can be recorded regardless of the input selector switch and TAPE2 MONITOR button settings. TUNER : To record from the equipment connected to the TUNER terminals. SOURCE : To record from the equipment selected by the INPUT SELECTOR knob. OFF : In this position, nothing from the REC terminals of TAPE 1/CD-R/MD is output. Set to this position when not recording; the cassette deck will be disconnected, improving sound quality. NOTE: The function selected using the INPUT SELECTOR knob will be recorded irrespective of the position of the REC SELECTOR switch (TAPE 2 MONITOR terminals). CD
0 LOUDNESS button/indicator
Use when listening at low volume level. Boosts low and high frequencies to give added punch to playback even at low volume level. NOTE: This button does not operate at DIRECT ON mode.
- TREBLE tone control
Use to adjust the high-frequency tone. When turned to the right, the high-frequency tone is emphasized; when turned to the left, the high-frequency tone is de-emphasized. NOTE: This control does not operate at DIRECT ON mode.
= BASS tone control
Use to adjust the low-frequency tone. When turned to the right, the low-frequency tone is emphasized; when turned to the left, the low-frequency tone is de-emphasized. NOTE: This control does not operate at DIRECT ON mode.
~ PHONES jack
When using headphones, insert the plug into this jack.
8 BALANCE control
Should normally be left in the center position. If the right side is louder, turn toward the L (left) position and if the left side is louder, turn toward the R (right) position. SPEAKERS B (ON/OFF) button/indicator
Use this button to listen to the speaker system connected to the SPEAKERS B terminals. Set to this position when listening with headphones.
9 DIRECT/SB MODE button/indicator
Press and hold the button for more than 3 seconds to switch SB mode ON. (Volume indicator goes out) Press and hold the button for more than 3 seconds again to switch SB mode OFF. (Volume indicator lights) [DIRECT] Use this button when you do not wish to pass the output from input terminal equipment through the various frequency adjusting circuits (BASS, TREBLE, BALANCE, LOUDNESS). The signals input through the input terminals are reproduced without passing through the various frequency adjusting circuits. This results in flat, pure sound which is a more faithful reproduction of the input source. [SB MODE] The SB mode is a special mode in which the amplifier does not accept remote control except power ON/OFF (But all of the facilities can be controled by manual as same as SB mode OFF. ). [. . . ] ± 8 dB (10 kHz) Loudness contour (volume control set at 30 dB position) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . + 5 dB (100 Hz)/ + 3 dB (10 kHz)
Accessories
Remote control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Batteries (AA/R6P) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]