User manual MITSUBISHI GB-24A FOR INITIAL SETTING WEB

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MITSUBISHI GB-24A. We hope that this MITSUBISHI GB-24A user guide will be useful to you.


MITSUBISHI GB-24A FOR INITIAL SETTING WEB: Download the complete user guide (1856 Ko)

You may also download the following manuals related to this product:

   MITSUBISHI GB-24A WEB BROWSER (2099 ko)

Manual abstract: user guide MITSUBISHI GB-24AFOR INITIAL SETTING WEB

Detailed instructions for use are in the User's Guide.

[. . . ] Mitsubishi Electric Air-conditioner Control System Centralized Controller GB-24A Operation Manual for Initial Setting Web Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-1 Terms Used in This Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-2 Computer Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 Setting the Operating Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2-1 Setting the PC IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2-2 Setting the Web Browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 Performing Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3-1 Entering the User Name and the Password, and Connecting to the GB-24A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4 Initial Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 4-1 Setting the Current Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 4-2 Setting Basic Information and External Input Functions . . . . . . . . . . . . . . . . . . 8 4-3 Group Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 4-4 Interlocked Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 4-5 Block Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 5 Functions 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5-1 Error mail reports/E-mail communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5-2 Settings for measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 6 Functions 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 6-1 Limiting the Set Temperature Operating Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 6-2 Night Mode (Silent Mode) Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 7 User Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 8 Registering a License for Optional Functions . . . . . . . . . . . . . . . . . . . . . . . . 30 Before using the web browser to set the GB-24A controller, please read this operation Manual carefully to ensure correct operation. Retain this manual for future reference. 1 Introduction Special features of Mitsubishi Electric Corporation's "Centralized Controller GB-24A" are that a PC connected to a LAN can be used to monitor the operation condition of air conditioners, perform air conditioner operations, and make initial settings. The document explains the procedures for performing initial settings for the Centralized Controller GB-24A using the web browser. 1-1 Terms Used in This Manual - "Click" refers to positioning the mouse cursor on the object (such as button or folder), pressing down, and releasing the left mouse button once. - Unless otherwise specified, the example screen images used in this manual are Windows XP® and Internet Explorer 6. 0 screen images. Note: Windows is a registered trademark or trademark of Microsoft Corporation USA in the United States and other countries. 1-2 Computer Requirements To monitor and operate air conditioners by web browser, computer must include the following requirements. [. . . ] Note: MA remote controls do not need to be registered to a group. (4) To register system remote controllers in a group, click on the [System Controller Registration] field to display the [Select Unit Addresses] screen, and click on the numbers corresponding to the units to be registered. The ones that are selected will be shown with a yellow-green background. Deselected items will be shown with a gray background. Note: The combined number of system controllers and remote controls cannot exceed four. 4-3-3 Registering general equipment in the group (1) To register general equipment in a group, click on the [Air Conditioner and General Equipment Registration] field to display the [Select Unit Addresses] screen, and select the [General Equipment (via PAC-YG66DCA)]. of the general interface device (PAC-YG66D) that is connected to the general equipment to be registered. will be displayed with a red frame (selected state), and select the contact No. To disconnect the general equipment, select the interface device No. , and click the contact No. will be displayed in gray (unselected state). Note: A maximum of 16 general equipment can be registered in one group. Note: To change the registered units to general equipment in the group in which air-conditioners are registered, disconnect the air-conditioners first. (2) To change the icon, click the right or left arrow. (3) In the [Allow Operation] section, select whether to enable or disable the ON/OFF operation on the Web browser operation screen. Select [In batch and on individual group] to enable only when the collective operation is performed. (4) In the [Monitor] section, select whether to display I/P to or from the general equipment on the monitor screen. 16 4-4 Interlocked Setting To interlock the operation of LOSSNAY with the run/stop status of the indoor units, click on [Initial Settings]-[Interlocked LOSSNAY] in the menu to bring up the Interlocked LOSSNAY screen, and enter the interlock conditions. Click [Save Settings] to send setting data to the GB-24A. Note: If the user logs in as a manager, the operations may be prohibited. Interlocked LOSSNAY Registration Register the interlocked ventilation equipment here. Click to bring up the registration screen. Interlocked Indoor Units Registration Register the indoor units to which LOSSNAY units are interlocked here. Click to bring up the registration screen. Refresh Read setting data from GB-24A. Save Settings Send setting data to GB-24A. (1) Click in the Interlocked LOSSNAY registration field to display the [Select a Unit Address] screen, and click on the numbers corresponding to the units to be registered. The ones that are selected will be shown with a yellow-green background. Deselected items will be shown with a gray background. (2) Click on the Interlocked Indoor Unit Registration field to display the [Select Unit Addresses] for the indoor units, and click on the numbers corresponding to the units to be registered. Deselected items will be shown with a gray background. Note: A maximum of 16 indoor units can be registered to operate with one ventilator. 17 4-5 Block Setting By performing block settings, multiples of air conditioner groups can be collectively monitored or operated from the Web. Bring up the Block Setting screen by clicking [Initial Settings]-[Blocks] in the menu, and register the groups in the block to utilize these features. Click [Save Settings] to send setting data to the GB-24A. Note: If the user logs in as a manager, some of the operations may be prohibited. Block Name Register the block name to be displayed on the Web screen here. Group Registration Register the groups to be included in the block here. Refresh Read setting data from GB-24A. Save Settings Send setting data to GB-24A. 4-5-1 Registering a block name In the [Block Name] field on the screen, register the block name to be displayed on the Web screen, using a name consisting of no more than 20 characters Note: The following characters cannot be used in the group name: < > & " ` 4-5-2 Registering a group in a block Click on the Group Registration field to display [Select Groups], and click on the numbers corresponding to the groups to be registered. The ones that are selected will be shown with a yellow-green background. (Putting a cursor on the group number will display the group name. ) To cancel the selection, click on them again. Deselected items will be shown with a gray background. 18 5 Functions 1 5-1 Error mail reports/E-mail communication Click on [Functions 1] ­ [E-Mail] in the menu to open the [E-mail] window and make necessary settings to perform remote monitoring via mail, using error mail report or the maintenance tool. [. . . ] Note: The set temperature range for all modes can be limited on the browser operation screen (for administrator regardless of any settings being made. Note: If the user logs in as a manager, some of the operations may be prohibited. Batch operations Click to set all groups collectively. Group No. , group name Group numbers and group names will be displayed. Copy Click to copy the settings. Paste Click to paste the settings. Set temperature range display The set temperature range is displayed. Refresh Read setting data from GB-24A. Upper limit (1) Click the set temperature range display to display the setting screen. Click [OK] to return the previous screen. Note: When displayed in Fahrenheit, the temperature is displayed in 2°F increments. (2) Click [Save Settings] to send setting data to GB-24A. Note: When copying settings of a group to another group, click [Copy] button. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MITSUBISHI GB-24A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MITSUBISHI GB-24A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.