User manual LEICA EG F V1.0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LEICA EG F. We hope that this LEICA EG F user guide will be useful to you.


LEICA EG F V1.0: Download the complete user guide (599 Ko)

You may also download the following manuals related to this product:

   LEICA EG F V1.0 (602 ko)
   LEICA EG F V1.0 (604 ko)
   LEICA EG F V1.1 (621 ko)
   LEICA EG F V1.1 (324 ko)
   LEICA EG F V1.1 (355 ko)
   LEICA EG F V1.1 (343 ko)
   LEICA EG F V1.1 (356 ko)
   LEICA EG F V1.1 (307 ko)
   LEICA EG F V1.1 (365 ko)
   LEICA EG F V1.1 (356 ko)
   LEICA EG F V1.1 (360 ko)
   LEICA EG F V1.1 (360 ko)
   LEICA EG F BROCHURE (118 ko)
   LEICA EG F BROCHURE (118 ko)
   LEICA EG F BROCHURE (118 ko)

Manual abstract: user guide LEICA EG FV1.0

Detailed instructions for use are in the User's Guide.

[. . . ] Any reproduction of text and illustrations (or of any parts thereof) by means of print, photocopy, microfiche, web cam or other methods ­ including any electronic systems and media ­ requires express prior permission in writing by Leica Microsystems Nussloch GmbH. For the instrument serial number and year of manufacture, please refer to the name plate at the back of the instrument. © Leica Microsystems Nussloch GmbH Issued by: Leica Microsystems Nussloch GmbH Heidelberger Str. 17-19 D-69226 Nussloch Germany Phone: Fax: e-mail: Internet: Leica EG F + 49 62 24 143-0 + 49 62 24 143-2 00 histo_info@leica-microsystems. com http://www. histo-solutions. com 3 Table of contents 1. [. . . ] 11 4. 1 4. 2 4. 3 5. Warranty and service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4 Instruction Manual V1. 0 ­ 03/2003 1. 1. 1 Symbols in this manual and their meaning Dangers, warnings and cautions appear in a gray box and are marked by a warning triangle . Important notes 1. 2 Designated use The Leica EG F are electrically heated forceps that are used to transfer and orient histologic tissue samples. Any use of the instrument other than its designated use is considered improper. Notes, i. e. important information for the user, appear in a gray box and are marked with . (5) (Fig. in drawings or to the drawings themselves. If additional requirements on accident prevention and environmental proctection exist in the country of operation, this instruction manual must be supplemented by appropriate instructions to ensure compliance with such requirements. Instrument surfaces which become hot during operation are marked with this symbol Instrument type: All information contained in this instruction manual applies solely to the instrument type indicated on the cover page. Required information for all enquiries For any enquiries please be sure to specify: · Instrument type · Serial number A name plate with the instrument serial number is attached to the bottom of the instrument. Leica EG F 5 2. Safety Be sure to comply with the safety instructions and warnings in this chapter. Be sure to read these instructions, even if you are already familiar with the operation and use of other Leica products. 2. 1 Safety instructions This instruction manual contains important instructions and information regarding the operational safety and maintenance of the instrument. The instruction manual is an important part of the product, which must be read carefully prior to setup and use and must always be kept near the instrument. This instrument was built and tested in accordance with the safety regulations for electrical measuring, control, regulating and laboratory devices as specified below: · EN 61010 -1 · EN 61010 -2 · EN 61326-1. · EN 61000 -3-2 · EN 61000 -3-3 In order to maintain this condition and ensure safe operation, the operator must observe all the instructions and warnings contained in this instruction manual. 6 Instruction Manual V1. 0 ­ 03/2003 2. Safety 2. 2 Warnings To ensure perfect operation of the instrument, the following safety instructions and warnings must be observed: The instrument must be connected to mains only with one of the supplied power cords and only to grounded sockets. The protective function must not be removed through the use of an extension cord without protective earth conductor. Extreme temperature fluctuations between storage facility and setup site as well as high humidity may cause condensation to form. In this case, a two-hour waiting period must be maintained before switching on the instrument. Failure to observe the waiting period may result in damage to the instrument. It may only be used according to its designated use and the instructions in this instruction manual. The instrument may be opened for maintenance or repair work by authorized service technicians only. While handling cleaning materials, observe the safety regulations of the manufacturer and the applicable laboratory regulations. Before replacing the fuses, switch the instrument off and pull the power plug from the wall socket. For corresponding fuse specifications see Chapter 4. 3 "Technical Data. " Leica EG F 7 3. 3. 1 Installation Scope of delivery The Leica EG F standard delivery consists of: · control unit · heatable forceps, tip width 1 mm · forceps holder with paraffin collecting tray · 1 set of power cords (see p. 9) · 1 set of fuses · instruction manual. Carefully check the delivery against the packing list, delivery note and your order. Should there be any discrepancy, please contact the Leica sales unit handling your order or your Leica dealer. 3. 2 Setting up the instrument · Carefully remove the control unit from its packaging. [. . . ] Use only the supplied replacement fuses. · Before connecting the power cord, ensure that the mains switch (1) is set to off = 0. · Select the power cord with the correct connector for your mains power socket from the supplied set of power cords. The instrument must be connected to mains only with the supplied power cord and only to a grounded socket. · Insert a small screwdriver into the cutout (5) and carefully pry out the insert. · Replace the defective fuses, reinsert the fuse housing in the instrument and press down until it snaps into place (audible click). · Connect the plug of the power cord to the connecting socket (6) on the rear of the control unit. · Plug the power cord into the mains power socket. 10 Instruction Manual V1. 0 ­ 03/2003 4. 4. 1 Overview ­ Components / functions Instrument features Control instrument (front view) Control panel Forceps holder Paraffin collecting tray Heatable forceps (tip width 1 mm), with cable Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LEICA EG F




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LEICA EG F will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.