User manual LA CROSSE TECHNOLOGY WS-8010U

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY WS-8010U. We hope that this LA CROSSE TECHNOLOGY WS-8010U user guide will be useful to you.


LA CROSSE TECHNOLOGY WS-8010U : Download the complete user guide (423 Ko)

You may also download the following manuals related to this product:

   LA CROSSE TECHNOLOGY WS-8010U INSTRUCTION MANUAL (738 ko)

Manual abstract: user guide LA CROSSE TECHNOLOGY WS-8010U

Detailed instructions for use are in the User's Guide.

[. . . ] WS-8010U Wireless 433 MHz Giant Radio Controlled Weather Center Instruction Manual TABLE OF CONTENTS Topic Inventory of Contents/ Additional Equipment Quick Set-up Detailed Set-Up Guide Battery Installation Program Mode Function Keys/Buttons LCD Contrast Setting Time Zone Setting Daylight Saving Time Setting Language Setting 12/24 hour Time Setting Selecting °F or °C World Time Setting World/Local Time Display Setting Graphic Time Display Options/Settings Time and Date Settings Features About WWVB Weather Forecast Icons/ Tendency Arrows Additional Sensors (Set-Up & Selection) Date/Rainfall Display Rain Gauge Set-Up Minimum & Maximum Records (Indoor, outdoor, & resetting) Mounting Troubleshooting Maintenance & Care Specifications Warranty Information Page 3 3 3-4 5 6 6 6 6-7 7 7 7 8 8-9 9 10 10-11 11-12 12-13 13 13-14 15-16 17 17 18 19 2 INVENTORY OF CONTENTS 1. TX4U--Remote Thermo-Hygro (temperature-humidity) includes: mounting bracket/receptor, rain cover, and two mounting screws. Instruction manual and warranty card. ADDITIONAL EQUIPMENT (not included) 1. Wait 5 minutes for the Weather Center to receive remote signals from the Remote Thermo-Hygro sensor. [. . . ] One tendency arrow points up (on the left side of the Display) and one points down (on the right side of the Display). An arrow pointing up indicates that the air pressure is increasing and the weather is expected to improve or remain fair, an arrow pointing down indicates that the air pressure is decreasing and the weather is expected to become worse or remain poor. ADDING MORE SENSORS (optional) The WS-8010U can receive signals from up to three Sensors. The Sensor model(s) that you choose will come with their own set of instructions--follow those instructions for a complete guide to setting up. Following are some brief instructions for the basic set-up of additional sensors with the WS-8010U. Additional sensors can be purchased through the same dealer as this Weather Center, or by contacting La Crosse Technology directly (contact information can be found at the end of this manual). A TX4U will monitor temperature and humidity (it is the same model that comes with the WS-8010U), a TX3U will monitor temperature only, and the TX3UP monitors temperature via a 10 foot probe for use in pools, spas, etc. The TX3 units do not monitor humidity, thus when they transmit their information to the Weather Center dashes "- -" appear in the Humidity Display. Note: When setting up multiple sensors it is important to remove the batteries from all existing units in operation, then to insert batteries first into all the sensors, and in numeric sequence. Transmission problems will arise if this is not done correctly and if the total time for set-up exceeds 6 minutes. SET-UP OF MULTIPLE SENSORS Note: The first sensor signal that the Weather Center receives is automatically assigned as the "boxed #1. " The 2nd to be received is the "boxed #2, " and the 3rd is the "boxed #3. " 1. It is necessary to remove the batteries from all units currently in operation. 6. In sequential order, install batteries into the sensors (follow the same battery installation procedures seen in section I. Follow the Programming Mode instructions to program and set-up the Weather Center. B. To view the outdoor temperature and humidity from a different sensor, press key #1. A shift from a "boxed #1" to a "boxed #2" should be observed under the DATE DISPLAY (between the Outdoor Temperature and Outdoor Humidity Displays). Press key #1 a second time to shift from the "boxed #2" to the "boxed #3". (Information will display only if you have three sensors in operation). IV. DATE DISPLAY Note: The DATE DISPLAY defaults to the month/date/year format. This changes the DATE DISPLAY from the standard month/date/year to a display showing the weekday/month/date. Press key #2 to change back to the original date display. 2. Key #1 Key #2 Key #3 V. RAINFALL DISPLAY (optional) Note: If the Rainfall feature is opted, its information will display in the Date Display, in two possible configurations. Press key #2 again to change from the DATE DISPLAY to the RAIN DISPLAY. [. . . ] Do not use solvents or scouring agents--they may mark and damage the displays and casings. Immediately remove all low powered batteries to avoid leakage and damage. Contact La Crosse Technology for Repairs. 17 SPECIFICATIONS Temperature measuring range Indoor: Outdoor: 32°F to 140°F with 0. 2°F resolution. (-29. 9°C to 59. 9°C with 0. 1°C resolution). Relative Humidity measuring range Indoor/Outdoor: Indoor Temperature checking interval: Indoor Humidity checking interval: Outdoor Temperature/Humidity reception: Transmission Range: Power Supply Weather Center: Sensor: Battery life cycle: Recommended battery type: Dimensions (L x W x H) Weather Center: Sensor: 20% to 95% with 1% resolution. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY WS-8010U




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY WS-8010U will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.