User manual LA CROSSE TECHNOLOGY WS-7395U-CH

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY WS-7395U-CH. We hope that this LA CROSSE TECHNOLOGY WS-7395U-CH user guide will be useful to you.


LA CROSSE TECHNOLOGY WS-7395U-CH : Download the complete user guide (1019 Ko)

Manual abstract: user guide LA CROSSE TECHNOLOGY WS-7395U-CH

Detailed instructions for use are in the User's Guide.

[. . . ] WS-7395U Wireless 433 MHz Radio-controlled Weather Station Instruction Manual TABLE OF CONTENTS Topic Inventory of Contents/Additional Equipment About WWVB Quick Set-Up Guide Detailed Set-Up Guide Battery installation Program Mode Program Sequence and Default Settings Function Keys Setting the LCD Contrast Setting the Time Zone Daylight Saving Time Setting Radio-controlled Time Setting 12/24-hour Time Setting Setting the Time Setting the Year, Day and Month Setting the Snooze Setting the Temperature Format Setting the Forecast Sensitivity Features Weather Forecast Icons and Tendency Arrows Indoor Temperature, Humidity, & Comfort Level Indicator Outdoor Temperatures Minimum & Maximum Records (Indoor, Outdoor, & Resetting) Moon Phase Current, minimum and maximum Dew Point Wind speed, wind chill and minimum and maximum Beaufort Scale Time Alarm Mounting Troubleshooting Maintenance & Care Specifications Warranty Information Page 3 3 4 5 6 6 6-7 7 7 7 8 8 9 9 9 10 11 11 11 11-12 13 13 13-14 14-16 16 17-18 19 19 20 21 2 INVENTORY OF CONTENTS 1. Mounting hardware Instruction manual and warranty card. Figure 1 Figure 2 Time LCD Date LCD Moon Phase LCD Indoor LCD Forecast LCD Outdoor LCD Wind Speed LCD Figure 3 ADDITIONAL EQUIPMENT (not included) 1. Two fresh AA 1. 5V batteries for the remote temperature/humidity sensor. The remote temperature/humidity sensor powers the wind speed sensor so no batteries are required. [. . . ] A sad face icon will be displayed when the temperature and humidity are outside the mentioned ranges. OUTDOOR TEMPERATURE AND HUMIDITY The temperature and humidity received from the remote temperature/humidity sensor is viewed in the OUTDOOR LCD. MINIMUM AND MAXIMUM TEMPERATURE RECORDS The WS-7395U keeps a record of the MINIMUM and MAXIMUM temperature, and the time and date of their occurrence, for both the indoor and outdoor modes. "MAX" appears to the right of the indoor temperature, indicating that the maximum temperature (along with the humidity measured at that time) and the time and date of occurrence are displayed. The maximum records will display for 30 seconds before returning to the normal display mode. 11 2. 3. Press and release the IN/HR button again (once while "MAX" is still displayed, twice otherwise). "MIN" appears to the right of the indoor temperature, indicating that the minimum temperature (along with the humidity measured at that time) and the time and date of occurrence are displayed. While "MIN" is still displayed press and release the IN/HR button again to return to the current data display. Or you can wait 30 seconds, during either the minimum or the maximum readings, and the unit will automatically return to current data readings. B. "MAX" appears above the outdoor temperature and the LCD will flash, indicating that the maximum temperature, and the time and date of occurrence are displayed. The maximum records will display for 30 seconds before returning to the normal display mode. 2. 3. Press and release the OUT/MIN button again (once while "MAX" is still displayed, twice otherwise). "MIN" appears to the right of the outdoor temperature, indicating that the minimum temperature and the time and date of occurrence are displayed. While "MIN" is still displayed press and release the OUT/MIN button again to return to the current data display. Or you can wait 30 seconds, during either the minimum or the maximum readings, and the unit will automatically return to current data readings. C. RESETTING THE MIMIMUM AND MAXIMUM RECORDS To reset the INDOOR records: 1. Press and release the IN/HR button to select the record you wish to reset, either MAX or MIN. The record is now reset and will show the current time in the TIME LCD and current indoor temperature and humidity in the INDOOR LCD. Press and release the OUT/MIN button to select the record you wish to reset, either MAX or MIN 2. The record is now reset and will show the current time in the TIME LCD and current outdoor temperature and humidity in the OUTDOOR LCD. 12 V. MOON PHASE There are 12 moon phases shown on the indoor weather station; the black portion signifies the portion of the moon visible in the sky. VIEWING THE CURRENT, MAXIMUM AND MINUMUM DEW POINT To view the current dew point: 1. The OUTDOOR LCD will switch to show the dew point (DEW POINT will be visible in the upper left corner of the OUTDOOR LCD). To view the maximum and minimum dew point readings: 1. The maximum or minimum value along with the time and date it was recorded will be displayed (MAX or MIN will be displayed below the words DEW POINT in the OUTDOOR LCD). After 30 seconds the display will automatically go back to the normal display mode showing the current dew point reading. 3. To reset the maximum or minimum dew point record: While viewing either the maximum or minimum dew point record: 1. [. . . ] Contact La Crosse Technology for repairs. SPECIFICATIONS Weather data measuring range: Indoor: 14. 2°F to 139. 8°F with 0. 1°F resolution (0°C to 59. 9°C with 0. 1°C resolution) "OFL" displayed if outside this range Outdoor and dew point: -21. 8°F to 157. 8°F with 0. 1°F resolution (-29. 9°C to 69. 9°C with 0. 1°C resolution) "OFL" displayed if outside this range Wind chill: -21. 8°F to 157. 8°F with 0. 1°F resolution (-29. 9°C to 69. 9°C with 0. 1°C resolution) "OFL" 19 Indoor relative humidity measuring range: Outdoor relative humidity measuring range: Wind speed measuring range: Weather data checking interval: Indoor temperature checking Every 15 seconds interval: Indoor humidity checking Every 20 seconds interval: Outdoor temperature checking Every 128 seconds interval (remote temperature/humidity sensor): Outdoor humidity checking Every 128 seconds interval: Wind speed checking interval: Average of 128 seconds with highest gust Outdoor temperature, humidity Every 128 seconds and wind speed reception (indoor weather station): Transmission range: 300 feet (in open space) Power Supply: Indoor weather station: 3 x AA, IEC LR6, 1. 5V Remote temperature/humidity 2 x AA, IEC LR3, 1. 5V sensor: Remote wind speed sensor: Supplied by remote temperature/humidity sensor Battery life cycle: Approximately 12 months Recommended battery type: Alkaline Dimensions (H x W x D): Indoor weather station: 13. 75" x 5. 65" x 1. 2" (350 x 144 x 30. 4 mm) Remote temperature/humidity 5. 4" x 2. 25" x 2. 25" sensor: (137 x 56. 2 x 56. 2 mm) Remote wind speed sensor: 7. 5" x 2. 2" x 2. 2" (191. 2 x 55. 8 x 56 mm) displayed if outside range 1% to 99% with 1% resolution ("- -" displayed if outside this range 1% to 99% with 1% resolution ("- - " displayed if outside this range 0 to 111. 8 mph (0 to 50 m/s) WARRANTY INFORMATION La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship. This limited warranty begins on the original date of purchase, is valid only on products purchased and used in North America and only to the original purchaser of this product. To receive warranty service, the purchaser must contact La Crosse Technology, Ltd for problem determination and service procedures. Warranty service can only be performed by a La Crosse Technology, Ltd authorized service center. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY WS-7395U-CH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY WS-7395U-CH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.