User manual HAIER HSU-18HEK03-R2 INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HSU-18HEK03-R2. We hope that this HAIER HSU-18HEK03-R2 user guide will be useful to you.


HAIER HSU-18HEK03-R2 INSTALLATION: Download the complete user guide (7949 Ko)

You may also download the following manuals related to this product:

   HAIER HSU-18HEK03-R2 (2294 ko)
   HAIER HSU-18HEK03-R2 (2294 ko)
   HAIER HSU-18HEK03-R2 (2294 ko)
   HAIER HSU-18HEK03-R2 (2294 ko)
   HAIER HSU-18HEK03-R2 (2294 ko)
   HAIER HSU-18HEK03-R2 SERVICE MANUAL (1749 ko)

Manual abstract: user guide HAIER HSU-18HEK03-R2INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] more than 60cm more than10cm Fixing of outdoor unit Fix the unit to concrete or block with bolts (10mm) and nuts rmly and horizontally. When tting the unit to wall D E surface, roof or rooftop, x a supporter surely with nails or wires in consideration of earthquake and strong wind. If vibration may affect the house, x the unit by attaching a vibration-proof mat. more than15cm Please be subject to the actual product purchased , the above picture is just for your reference. Read this manual before installation Explain suf ciently the operating means to the user according to this manual 36 HSU-18HEK03/R2 Accessory parts Remote controller (1) R-03 dry battery (2) Mounting plate (1) Plastic cap (4) Ø4X25 Screw (4) Drain hose (1) Cushion (4) Heat insulation material Installation 1. [. . . ] Install piping hole cover and seal it off with putty after installation Wall hole Ø60mm Thickness of wall When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Indoor side Outdoor side (Section of wall hole) G Piping hole pipe Installation of the Indoor Unit Drawing of pipe [ Rear piping ] Draw pipes and the drain hose, then fasten them with the adhesive tape [ Left Left-rear piping ] In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials. Note When connecting the cable, con rm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. 37 HSU-18HEK03/R2 Installation Outdoor unit Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units 3 4 Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe , and the bending radius should be 30 to 40 mm or longer. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of gas. Pipe Diameter( ) 2 4 1(L) 2(N) Outdoor unit 2 Indoor unit Power cable: 1. 5mm Connecting wiring: 1(L) 2(N) 3 HSU-18RE03/R2 HSU-22RE03/R2 Fastening torque 18N. m 42 N. m 55N. m 60 N. m Liquid side6. 35mm(1/4") 4 2 Liqui Spanner Torque wrench s side9. 52mm(3/8") as side 12. 7mm(1/2") as side 15. 88mm(5/8") HSU-14HR03/R2 HSU-18HR03/R2 1( L) 2( N) 1(L ) 2 (N) Be careful that matters, such as wastes of sands, etc. If the pipe has to be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerant must be conducted by professional air conditioner engineer. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump, then charge additional refrigerant. 34 CAUTION Outdoor unit Indoor unit Power cable: . 5mm Connecting wiring: 5mm 2 (For: L N )+2x0. 75mm 2 HSU-18HEK03/R2 HSU-18HEA03/R2 HSU-18RH03/R2 HSU-18HRA03/R2 HSU-18HV03/R2 Outdoor unit Outdoor unit 2 Outdoor unit B A A Indoor unit B Indoor unit B Oil trap Indoor unit A Max. Elevation: Amax=10m In case the elevation A is more than 5m, oil trap shoud be installed every 5~7m Max. Length: Bmax=15m In case the pipe length B is more than 7m, the refrigerant should be charged, according to 20 g/m. 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar quali ed person. If the fuse on PC board is broken please change it with the type of T. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. Connection Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws. Insert the cable according to terminal number in the same manner as the indoor unit. If wiring is not correct, proper operation can not be carried out and controller may be damaged. Fix the cable with a clamp. Attaching Drain-Elbow If the drain-elbow is used, please attach it as gure. (Note: Only for heat pump unit. ) Purging Method:To use vacuum pump 1. Detach the service port's cap of 3-way valve, the valve rod's cap for 2-way valve and 3-way's, connect the service port into the projection of charge hose (Iow) for gaugemanifold. [. . . ] In case that the attached drain hose is in a room, please apply heat insulation to it without fail. 6. Detach the charge hose from the service port, open 2-way valve and 3-way. Turn the valve rod anticlockwiseuntil hitting lightly. 7. To prevent the gas leakage, turn the service port's cap, the valve rod's cap for 2-way valve and 3-way's a little more than the point where the torque increases suddenly. Check Items for Test Run Put check mark in boxes Gas leak from pipe connecting? [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-18HEK03-R2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-18HEK03-R2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.