[. . . ] Introduction
This instruction manual contains all the information regarding design, installation and start-up procedure for the electrical actuator unit type EA 30. Warnings: ¼ Do not work on this unit before disconnecting it from the mains!¼ The actuator is factory preset to a mains voltage of 230 V AC. [. . . ] Limit switch positions Switch S1 opens at <open> position Switch S2 opens at <closed> position (see diagram in the margin) Procedure Both switching cams S1 and S2 are to be adjusted so that the actuating angle is less than 90°). Drive the actuator until one limit switch, either <closed> or <open> is operated. The end positions can be adjusted by moving the switching cams, as the actuator follows them. ¼ For George Fischer ball valves an exact 90°) rotation should be set. ¼ For George Fischer butterfly valves the <closed> position should be adjusted according to the following directions.
S2 S1
GEORGE FISCHER . . .
49
G/2 a
Setting the <closed> position in actuators At the <closed> position in butterfly valves the disk is not exactly vertical to the pipe axis. Deviation values can be taken from the following table.
open
ab
b
DN mm 65 80
d mm 75 90
ab mm 4 4
50
GEORGE FISCHER . . .
5. 5 / 230 V, 5060 Hz (switchable) 24 V = / 24 V, 5060 Hz 48 V, 5060 Hz on request @2 W IP 65 in accordance with DIN 40050 @00% at 25 °C / 70% at 50 °C, 20 min Dependent on current and time (automatic reset) 1) Cable plug 3 P+E in accordance with DIN 43650 additional cable connections PG 270°, set to 90° 25 Nm 50 Nm @0° to +50 °C 2) 098%, non-condensing PP fiberglass reinforced external screws rust-proof visual, integrated
Power consumption Protection Duty cycle Overload protection Electric connection
Control time Angle of operation Continuous torque Peak torque Operating temperature Permissible humidity Body material Position indicator
1)
The overload protection is designed to protect both motor and power supply board. If the overload protection device has triggered, it will reset automatically when the unit has cooled down sufficiently and the actuator will operate again. @43 should be installed (see Item 6. 5).
2)
GEORGE FISCHER . . .
51
5. 2 Block Diagram
input voltage selection 230 V 1@5 V Closed 2 N S2
power supply overload protection
Open L
1
S1
M
N
230 V 1@5 V
reversing circuit
5. 3 Dimensions
72 56. 4 159
63. 7 185
120. 7
61 146
85
15
52
GEORGE FISCHER . . .
6. Assembly and Connection of Modular Components
The electrical actuator EA 30 is equipped with fastening points which allow for additional modular components to be mounted. The electrical connection is made by means of a second cable plug or a threaded cable joint (depending on the number of connecting wires). The respective kits are prepared for installation, the electric cables are cut to size and package accordingly. In the following sections, the corresponding assembly points and the wiring are illustrated.
GEORGE FISCHER . . .
53
6. 1 Mechanical limit switches
Description Kit with 2 additional auxiliary switches Kit with 4 additional auxiliary switches Kit with 2 additional auxiliary switches with gold contacts 1 2
1 Additional switching cams 2 Limit switch S5, S6 or S5 to S8
Technical Data 250 V , @0 A 250 V , @0 A 430 V = 1@00 mA
Code @99 @90 @38 @99 @90 @39 @99 @90 @49
Wiring diagram Nr. . 149
M
S1 S2 S6
14 2
S5
14 2
M
S1
S2
14
2
14
2
14
2
14
2
black
white
black red
FED 654N21 65
FED 4N2 1
1 3 2 1
B
A
DC
AC L1 N PE
B
A
DC
AC L1 N PE
54
GEORGE FISCHER . . .
6. 2 Inductive limit switches
The mechanical installation of these switches is identical to those under 6. 1. An additional metal part must be mounted so that the active surface of the inductive switch can be activated. Description Kit with 2 additional auxiliary switches inductive, with LED NPN Kit with 2 additional auxiliary switches inductive, with LED PNP Kit with 2 additional auxiliary switches inductive Namur Technical Data 9, 655 V = 0, 2 A 9, 655 V = 0, 2 A 524 V = @0 mA Code @99 @90 @46 @99 @90 @47 @99 @90 @48
Wiring Diagram Nr. @99 @90 @47 PNP
S6 +A S5 +A M S1 S2 +
Wiring Diagram Nr. [. . . ] +46(0)8/727 47 00, Fax +46(0)8/749 23 70 e-mail: info@georgfischer. se, Internet: http://www. georgfischer. se George Fischer Pte. Ltd. , ¢5 Kaki Bukit Road 2, KB Warehouse Complex, 4¢7 845 Singapore/Singapore Tel. +65(0)7/47 06 ¢¢, Fax +65(0)7/47 05 77, e-mail: info@georgfischer. com. sg George Fischer Inc. , 2882 Dow Avenue, Tustin, CA 92780-7285 Tel. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GEORG FISCHER EA30