User manual FABER LOOK ISOLA BRS X/V A90

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FABER LOOK ISOLA BRS X/V A90. We hope that this FABER LOOK ISOLA BRS X/V A90 user guide will be useful to you.


FABER LOOK ISOLA BRS X/V A90 : Download the complete user guide (9403 Ko)

Manual abstract: user guide FABER LOOK ISOLA BRS X/V A90

Detailed instructions for use are in the User's Guide.

[. . . ] If the extractor is used in conjunction with non-electrical appliances (e. Gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. When the cooker hood is used in conjunction with appliances supplied with energy other than electric, the negative pressure in the room must not exceed 0, 04 mbar to prevent fumes being drawn back into the room by the cooker hood. The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels. [. . . ] For concrete ceilings, use the appropriate plugs for the screw size (not provided). For wooden shelf, use 4 screws 12g with washers 22 and nuts 23, provided. Should it be necessary to adjust the height of the frame, proceed as follows: · Unfasten the metric screws joining the two opposite parts that Can be seen from the front; · Adjust the height of the frame as required, then replace the Screws removed as above, making sure that you insert 2 of them close to the panel lock; · Lift the frame, insert the slots onto the screws and slide them until they lock; · Tighten the two screws and insert the other two screws provided. 2, remove the film from the double sided adhesive and fix it inside the frame so as to hold it more firmly. Before final locking of the screws it is possible to make small Adjustments to the frame, making sure that the screws do not Come out of the adjustment slot. The Frame must be securely fastened both due to the weight of The Hood and the stress caused by occasional sideways pres- Sure on the Appliance when in position. That the base is stable even when the Frame is subjected to In all cases where the Ceiling is not sufficiently strong at the Point of suspension, the Installation technician must strengthen When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer. To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. 1 into the side of the Con- Insert the Connector 15 into the Support bracket 7. 3, fixing it to the upper part with Make sure that the Connector extensions outlet 14. Respondence with the Chimney openings both horizontally and vertically. Join the Connector 15 to the Hood canopy outlet using a rigid or flexible pipe ø¸150 mm, selection of which is at the discre- 12e tion of the installation technician. Make sure that the Activated charcoal odour filter has been Apply the Novastick tape 16 to the front edge of the Upper Chimney from the top part down to the start of the Lower Chimney. Fitting the Panel and Fixing the Hood Canopy Before fixing the Hood Canopy to the Frame: ?Unscrew the screws near the Air outlet and use these For attaching the Control Group 50; · Remove the Grease filters from the Hood Canopy; · Working from below, fix the Hood canopy to the Then hook the upper part of the Panel 3, adjusted to size, to the rubber supports in the upper part and in the lower part of the Frame. Slide the lower part of the Panel 3 until its metal tabs slot into the slots in the frame. Connect the Hood to the Mains Power Supply, inserting a bipolar switch with a contact aperture of at least 3 mm. Make sure that the Power cable has been properly inserted into the Control Board Unit socket. Connect up all the connectors to the sockets provided on the Control Board Unit, making sure they are compatible. Enables / Disables Keyboard Lock mode if pressed All the Leds light up in cycle and run a start-up sequence. Press and hold the button for approximately 5 seconds, with all the loads turned off (Motor and Lights), to turn the Activated Charcoal Filter alarm on. At the end of this time the system will return to the speed set previously. [. . . ] The Activated Charcoal Filter is only present on the Hoods in Recirculation version, and has the job of retaining smells in the flow of air that passes over it, until reaching saturation. This cannot be washed or regenerated, and must be changed when the Delay led on the display starts to flash, or at least once every 4 months. The Alarm signal, if it has been activated, only appears when the Suction motor is turned on. activating the alarm signal · In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on Turn the Lights and the Suction Motor off. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FABER LOOK ISOLA BRS X/V A90




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FABER LOOK ISOLA BRS X/V A90 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.