User manual FABER CUBIA GLOSS EG8 WH A45 ACTIVE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FABER CUBIA GLOSS EG8 WH A45 ACTIVE. We hope that this FABER CUBIA GLOSS EG8 WH A45 ACTIVE user guide will be useful to you.


FABER CUBIA GLOSS EG8 WH A45 ACTIVE : Download the complete user guide (4971 Ko)

Manual abstract: user guide FABER CUBIA GLOSS EG8 WH A45 ACTIVE

Detailed instructions for use are in the User's Guide.

[. . . ] Warning: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards. Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. The extractor hood has been designed exclusively for domestic use to Never use the hood for purposes other than for which it has been designed. Adjust the flame intensity to direct it onto the bottom of the pan only, making Sure that it does not engulf the sides. [. . . ] on the wall , trace: · A vertical line up to the ceiling or top limit, at the centre of the area where you intend to fit As shown, mark a reference point at 808 mm above the horizontal reference line, and at X Mm (X= see table in figure) to the right of the vertical reference line. Drill the points marked using a ø 12 mm bit · Insert plugs with screws and brackets 11a in the holes then tighten them. Adjust the two screws Vr of brackets 11a, by just placing them in position. Pull the Comfort Panel to open it, remove the filters one by One, push them towards the rear part of the unit and pull downwards at the same time . When installing the hood in ducting version, basing on the in- Staller's choice, a rigid or a flexible pipe with a ø 150 or 120 mm Is used in order to connect the hood to the air outlet piping. Pipe connection can be made on the upper part or on the rear side Before connecting the hood to the air outlet ducting remove the 9 has to be removed only in case the connecting diameter is 150. When drilling the air outlet hole in the wall proceed in accor- Dance with the scheme in the part concerning the wall drilling. Use a pair of tongs when breaking the rear air outlet hole in the In case the connection is made by using a ø 120 mm pipe insert The reduction flange 9 on the hood body outlet. Fix the metal cover 10 to the upper air outlet hole of the hood In case the connection is made by using a ø 120 mm pipe insert The reduction flange 9 on the hood body outlet. Use a pair of tongs when removing the central part of the metal cover 10. Fix the cover to the air outlet hole of the hood by us- Fix the pipe with an adequate quantity of pipe clamps. In case the components requested for the recycling functioning Have been removed earlier these have to be positioned again. Make sure that the Make sure that charcoal filters have been placed inside the Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan. Displays the set speed Displays the set speed Displays the set speed D Activate intensive speed from any other speed, Displays HI and the time remaining once very second. This speed is set to operate for 6 minutes, after which the system returns to the speed that was set before. Press and hold the button for approximately 5 seconds, with all the loads turned off (Motor and Lights), to turn the Activated Charcoal Filter alarm On and Off. Displays 24 and the spot at the bottom right flashes once Turns the suction motor on at speed one and every second, while the motor is running. When the filters alarm is triggered, the alarm can be reset by pressing and holding this button for approximately 3 seconds. When the procedure terminates, the indication shown previously turns off: FG indicates the need to wash the metal grease filters. The alarm is triggered after the Hood has been in operation for 100 working hours. FC indicates the need to change the activated charcoal filters, and also to wash the metal grease filters. [. . . ] ) · Replace, taking care to ensure that the handle faces forwards. It cannot be washed or regenerated, and must be changed when the FC symbol on the display appears, or at least once every 4 months. The Alarm signal, if it has been activated, only appears when the Suction motor is turned on. In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on Turn the Lights and the Suction Motor off. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FABER CUBIA GLOSS EG8 WH A45 ACTIVE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FABER CUBIA GLOSS EG8 WH A45 ACTIVE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.