User manual EUTECH INSTRUMENTS HIGHLOW CONDUCTIVITY TESTER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS HIGHLOW CONDUCTIVITY TESTER. We hope that this EUTECH INSTRUMENTS HIGHLOW CONDUCTIVITY TESTER user guide will be useful to you.


EUTECH INSTRUMENTS HIGHLOW CONDUCTIVITY TESTER : Download the complete user guide (124 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS HIGHLOW CONDUCTIVITY TESTER

Detailed instructions for use are in the User's Guide.

[. . . ] Out of warranty products will be repaired on a charge basis. Return Of Items Authorization must be obtained from Eutech's distributor before returning items for any reason. When applying for authorization, please include information regarding the reason the item(s) are to be returned. Note: We reserve the right to make improvements in design, construction and appearance of products without notice. [. . . ] · Replace all batteries if low battery indicator appears, or if readings are faint or unstable. · If you experience drift, periodically let electrode fully dry. When you need a new electrode, see "Electrode Replacement" on insert in back of box. Self-Diagnostic Messages bAt Weak batteries­replace with fresh ones specified by manufacturer. Or, Ur Over range/Under range signal, or electrode is not in contact with solution, or electrode is failing. ---- Calibration mode activated but not performed. 68X247755 11/00 Rev 0 Open this leaflet for calibration/testing/maintenance instructions. Changing Batteries 1. Recalibrate after battery change. Warranty Eutech Instruments warrants its meter free from manufacturing defects for 2 years and electrode module for 6 months. If repair, adjustment or replacement is necessary and has not been the result of abuse or misuse within the time period, please return the tester ­ freight prepaid ­ and correction will be made without charge. Out of warranty products will be repaired on a charge basis. Return Of Items Authorization must be obtained from Eutech's distributor before returning items for any reason. When applying for authorization, please include information regarding the reason the item(s) are to be returned. Note: We reserve the right to make improvements in design, construction and appearance of products without notice. Prices are subject to change without notice. + · Waterproof & Floats · Replaceable Electrode · Auto-off · Automatic Temperature Compensation (ATC) Waterproof ECScan Low Instructions Before You Begin Remove electrode cap. Soak electrode for a few minutes in alcohol to remove oils. Conductivity Testing 1. Wait for reading to stabilize (Automatic Temperature Compensation corrects for temperature changes). Note: Tester automatically shuts off after 8. 5 minutes of non-use. Calibration Tester is factory calibrated. However, to ensure accuracy, calibrate conductivity on a regular basis. Select a calibration standard appropriate for the ECScan Low tester (between 200 µS and 1990 µS). [. . . ] ---- Calibration mode activated but not performed. 68X247754 11/00 Rev 0 Twist-off Battery Compartment REMOVE THE OLD ELECTRODE A (Picture A) Lanyard connection Replaceable Sensor REPLACE THE ELECTRODE B (Picture B) · Push-button calibration · Fast, stable, repeatable readings · Available through authorized distributors SPECIFICATIONS Tester Range TDScan TDScan Low High 0 to 1990 ppm 10 ppm ECScan ECScan Low High 0 to 0 to 0 to 10. 00 1990 19. 90 ppt µS/cm mS/cm 0. 10 10 0. 10 ppt µS/cm mS/cm ±1% Full Scale 0. 4 to 1. 0 selectable 200 to 2 . 00 to 200 to 2. 00 to 1990 10. 00 1990 19. 90 ppm ppt µS/cm mS/cm 1 point (calibration range is ±30% of factory default parameter) 0 to 50 °C 2% per °C 0 to 50 °C Four X 1. 5V (Type: A76, LR 44 or V136A); > 140 hrs continuous use Tester: 16. 5 cm x 3. 8 cm; 90 g Boxed: 22 cm x6 cm x 5 cm; 170 g Manufactured By: Electrode Replacement You can replace the electrode module at the fraction of the cost of a new tester. When the tester fails to calibrate or gives fluctuating readings in calibration standards, you need to change the electrode. 1. With dry hands, grip the ribbed tester collar with electrode facing you. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS HIGHLOW CONDUCTIVITY TESTER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS HIGHLOW CONDUCTIVITY TESTER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.