User manual EUTECH INSTRUMENTS CYBERCOMM PRO FOR CYBERSCAN CON 1500

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS CYBERCOMM PRO FOR CYBERSCAN CON 1500. We hope that this EUTECH INSTRUMENTS CYBERCOMM PRO FOR CYBERSCAN CON 1500 user guide will be useful to you.


EUTECH INSTRUMENTS CYBERCOMM PRO FOR CYBERSCAN CON 1500 : Download the complete user guide (1685 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS CYBERCOMM PRO FOR CYBERSCAN CON 1500

Detailed instructions for use are in the User's Guide.

[. . . ] Data type stored is in the ASCII format. © Windows is the registered trademark of Microsoft Corporation 1. 2 System Requirements To run the CyberComm Pro DAS software, the following items are required: 1 2 3 4 IBM Compatible PC Pentium and above Windows Operating Systems 95 and above VGA/SVGA Monitor RS232C Serial Communication Cable 1. 2. 1 Setting the Communication Parameters The meter is capable of different communication configurations for baud rate, parity and stop bits. The values chosen for these parameters of the meter must match those chosen for the computer, same goes for the serial printer if it is connected. 1 Instruction Manual CyberComm CON 1500 2 2. 1 INSTALLATION OF CYBERCOMM DATA ACQUISITION SOFTWARE (DAS) Loading of CD-ROM See Figure 1. Before running the program, check that the CyberScan CON 1500 meter is properly connected to the computer. It is preferable to connect to either one of the COM (serial) ports available on a computer. [. . . ] Maximum default time is 10080 minutes (1 week). Figure 7: Data Log Options Click OK to exit and save settings. After matching the Communication Settings and setting the Data Log Options between your computer and the CyberScan CON 1500 meter using CyberComm Pro, you can now capture data into your computer for analysis and storage purposes. EXAMPLE: Set Time between successive readings to be `10 sec', Length of Time to Capture Data to be `5 min'. You will be able to retrieve the recorded data in every 10 seconds during a 5 minutes duration measurement. Reference source not found. : Retrieve Recorded Data. 3. 3 Connect to Meter (File) See Figure 8. From the Main Menu, select Connect to Meter to start the communication between your computer and the meter. The complete main window the CyberComm Pro will start after connection to the meter: NOTE: All keys on the meter are disabled after connection to computer. 6 Instruction Manual CyberComm CON 1500 4 4. 1 MAIN WINDOW (AFTER CONNECTING METER TO COMPUTER) CyberComm Pro Manuals (Help) See Figure 8 and 9. The main menu appears with the File and Help drop down menus, each having a list function settings shown below. Soft copies of the CyberComm Pro Software User Guide Manuals are available in the program itself. Select the manual option with reference to the meter you are using. Figure 8:Running CyberComm Pro/ Complete Main Menu (Connected to meter) Figure 9: CyberComm Pro Main Menu (Partial) 7 Instruction Manual CyberComm CON 1500 4. 1. 1 File Options (File) See Figure 10. Enter the relevant information for useful future references and type a file name/or file location that you wish to store these details. Click OK upon completion to save information. Figure 10: File Options 4. 1. 2 About CyberComm Pro (Help) See Figure 6. By selecting About CyberComm Pro from the Help drop down menu, the dialogue box will be shown as below. Select OK button to exit. Figure 11: About CyberComm Pro 8 Instruction Manual CyberComm CON 1500 4. 2 Sub menus & Function Icons on the CyberComm Program See Figure 12. The figure shows the CyberComm Pro software Main Menu after linking with the meter. From this menu, most of the meter key functions can be emulated except replatinisation of conductivity probe. This Sub Menu has following features: Figure 12: Running CyberComm Pro/ Complete Main Menu (Connected to meter) NOTE: All keys on the meter are disabled after connection to computer. 9 Instruction Manual CyberComm CON 1500 4. 2. 1 Function Icons See Figure 13. The function icons on the main menu each serve a vital role in the CyberComm Pro software, providing user friendly one click access. Figure 13: Function Icon Panel (extracted from Figure 12) Icon no. 1 Function Name Description Click on this icon to start recording meter readings, readings will be shown on the CyberComm Pro main menu. Data captured will also be stored to the hard disk (in a ". csv" formatted file). A pop-up menu will prompt you whether to overwrite saved data should you already have recorded data reading. Tracking means that the current reading is always visible and the graph window will scroll to show the current reading like a chart recorder. Refer to Icon 2. Record 2 Resume Tracking 3 Pause Tracking 4 Scroll/Zoom Use this function to drag along single axis at a time to expand selected region of the reading curve Click to enlarge screen image Click to minimise screen image. You are able to drag the guide across the readings to get the exact or extrapolated readings at any point on the curve. [. . . ] Select the `copy' icon and the data readings will be copied to the `clipboard' 3. Select to paste the copied data readings in a document of your preference 6. 2 Paste data in Microsoft Word© Follow steps instructed in Section 6. 1: Steps to export data readings from CyberComm Professional:. Select `Edit' from the menu and click `Paste' to transfer data from the clipboard to the current word document. The data will be displayed as shown below. Figure 21: Paste data readings in a Microsoft Word© document 17 Instruction Manual CyberComm CON 1500 6. 3 Paste data in Microsoft Excel© , WordPad and Notepad Follow steps instructed in Section 6. 1: Steps to export data readings from CyberComm Professional: and paste the data copied from the CyberComm Pro to a new document. Figure 22: Paste data readings in a Microsoft Excel© document 18 Instruction Manual CyberComm CON 1500 Figure 23: Paste data readings in a Microsoft Notepad© document 19 Instruction Manual CyberComm CON 1500 7 7. 1 PRINT READINGS Printing using a serial printer Connect the CyberScan CON 1500 bench meter to the serial printer via RS232C cable (refer to the list of accessories). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS CYBERCOMM PRO FOR CYBERSCAN CON 1500




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS CYBERCOMM PRO FOR CYBERSCAN CON 1500 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.