User manual EUTECH INSTRUMENTS ALPHA RES 1000 CONTROLLER TRANSMITTER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA RES 1000 CONTROLLER TRANSMITTER. We hope that this EUTECH INSTRUMENTS ALPHA RES 1000 CONTROLLER TRANSMITTER user guide will be useful to you.


EUTECH INSTRUMENTS ALPHA RES 1000 CONTROLLER TRANSMITTER : Download the complete user guide (686 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS ALPHA RES 1000 CONTROLLER TRANSMITTER

Detailed instructions for use are in the User's Guide.

[. . . ] Alpha RES 1000 Controller/Transmitter Resistivity ROSS and the COIL trade dress are trademarks of Thermo Fisher Scientific Inc. AQUAfast, Cahn, ionplus, KNIpHE, No Cal, ORION, perpHect, PerpHecT, PerpHecTion, pHISA, pHuture, Pure Water, Sage, Sensing the Future, SensorLink, ROSS, ROSS Ultra, Sure-Flow, Titrator PLUS and TURBO2 are registered trademarks of Thermo Fisher. 1-888-pHAX-ION, A+, All in One, Aplus, AQUAsnap, AssuredAccuracy, AUTO-BAR, AUTO-CAL, AUTO DISPENSER, Auto-ID, AUTO-LOG, AUTO-READ, AUTO-STIR, Auto-Test, BOD AutoEZ, Cable-Free, CERTI-CAL, CISA, DataCOLLECT, DataPLUS, digital LogR, DirectCal, DuraProbe, Environmental Product Authority, Extra Easy/Extra Value, FAST QC, GAP, GLPcal, GLPcheck, GLPdoc, ISEasy, KAP, LabConnect, LogR, Low Maintenance Triode, Minimum Stir Requirement, MSR, NISS, One-Touch, OneTouch Calibration, One-Touch Measurement, Optimum Results, Orion Star, Pentrode, pHuture MMS, pHuture Pentrode, pHuture Quatrode, pHuture Triode, Quatrode, QuiKcheK, rf link, ROSS Resolution, SAOB, SMART AVERAGING, Smart CheK, SMART STABILITY, Stacked, Star Navigator 21, Stat Face, The Enhanced Lab, ThermaSense, Triode, TRIUMpH, Unbreakable pH, Universal Access are trademarks of Thermo Fisher. Guaranteed Success and The Technical Edge are service marks of Thermo Fisher. [. . . ] 8) Continue with additional Advanced Set-up procedures, or return to the Measurement mode by pressing the and keys (escape) simultaneously. 6) 7. 2. 1 Setting manual temperature compensation HOLD SETUP Atc on HOLD SETUP 0. 0 o C 25. 0 ATC HOLD SETUP oFF Atc HOLD SETUP 25. 0 P. C Note: This parameter is unavailable if ATC is selected. For manual temperature compensation, two different temperatures: process and calibration can be input independently. Example: setting a calibration temperature of 25 oC lets you calibrate using standard buffer solutions at 25 oC, even if process temperature is different. Push ENTER key and scroll to Advanced Set-up security code "22". Push ENTER key and Press or keys to scroll till display shows "Set oC". 2) 3) Pressing the or keys keys toggle between ATC `on' or `off' (default setting is ATC on). Upper display shows current process temperature and lower display shows "P. oC" to indicate process temperature. oC. HOLD SETUP 25. 0 6) 7) 4) 5) Press or keys to adjust process temperature value from ­9. 9 to 125 C. C Press ENTER key. Upper display shows current calibration temperature and lower display shows "C. oC" to indicate calibration temperature. Press or keys to adjust calibration temperature value, ­9. 9 to 125 oC. Continue with additional Advanced Set-up procedures, or return to Measurement mode by pressing and keys (escape) simultaneously. 12 Operating Instructions Alpha RES 1000 7. 3 Control Relay A/Control Relay B (SP1/SP2) sub-function SP1 option sets operating parameters for Relay A; and SP2 for relay B. Since these groups have the same set-up parameters, they are described together. HOLD SETUP HOLD SETUP HOLD SETUP HOLD SETUP HOLD SETUP HOLD SETUP SP 1 7. 3. 1 1) 1. 00 SP 1 Lo SP 1 0. 20 HYS 0 On. d 0 Of. d Entering the Set point 1 (Set point 2) sub-function Enter Advanced Set-up mode. Push the ENTER key and scroll to Advanced Set-up security code "22". Press the or keys to scroll until the upper display shows SP1 (SP2). HOLD SETUP HOLD SETUP SP 1 2) 7. 3. 2 Selecting the set point values This lets you choose the value that will cause your controller to activate (Default: SP1 = 1. 00 m; SP2 = 19. 00 m). The upper display shows the current set point value and the lower display shows SP1 (SP2). 3) Press the or keys to select your value for Set point 1 (Set point 2). Press the ENTER key to confirm your selection. 1. 00 HOLD SETUP m SP 1 SP 1 Lo 4) 5) Proceed to 7. 3. 3, or return to Measurement mode by pressing the and keys simultaneously (escape). 7. 3. 3 Choosing High or Low set points When `Lo' is selected, the control relay is activated when the value is lower than SP1 (SP2). When `Hi' is selected, the control relay is activated when the value is higher than the set point (SP1/SP2). Using both SP1 and SP2, you can select lo/lo, lo/hi, hi/lo, or hi/hi set points (Default: SP1 = Lo; SP2 = Hi). 2) Press the ENTER key until the upper display shows Lo or Hi (for low or high set point) and the lower display shows SP1 (SP2). 3) Press or keys to select low (lo) or high (hi) set point for SP1 (SP2). 4) Proceed to 7. 3. 4, or return Measurement mode by pressing and keys simultaneously (escape). 7. 3. 4 Selecting a hysteresis (dead band) value (0. 000 to 0. 200 m or 0. 00 to 2. 00 m) Hysteresis prevents rapid contact switching if the value is fluctuating near the set point. It does this by overshooting the set point value to a specified hysteresis value (default is 0. 20 m). [. . . ] 5) 22 Operating Instructions Alpha RES 1000 9 Technical Specifications Resistivity Range 0. 00 to 19. 99 m/cm 0. 000 to 1. 999 m/cm Resolution 0. 01 m/cm 0. 001 m/cm Default Cell Constant, K 0. 01 0. 1 -9. 9 to 125 oC 0. 1 oC ± 0. 5 oC Pt 1000/Pt 100 Auto / manual (reference at 25. 0 oC) Limit/Proportional controller 0 to 1999 sec. 600 VA 110 / 220 VAC (jumper selectable) 48 to 62 Hz 0/4 to 20 mA, galvanically isolated max. 600 Terminal blocks 5-pole / 17-pole, removable slow-blow 250 V / 100 mA According to EN 50081-1 According to EN 50082-1 0 to 50 oC 10 to 95%, non-condensing 175 x 96 x 96 mm max. 0. 7 kg ABS with polycarbonate (front housing) IP 54 / IP 65 Temperature Resolution Relative Accuracy Sensor Temperature Compensation Set-point and Controller Functions Controller characteristics Pickup / Dropout delay Switching Condutivity hysteresis Contact outputs, controller Switching voltage Switching current Switching power Alarm/Wash Functions Function (switchable) Pickup delay Switching voltage Switching current Switching power Electrical Data and Connections Power Requirements Frequency Signal Output Signal Output Load Connection terminal Mains fuse / fine wire fuse EMC Specifications Emissions Susceptibility Environmental Conditions Ambient temp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA RES 1000 CONTROLLER TRANSMITTER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA RES 1000 CONTROLLER TRANSMITTER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.