Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
pH 500 LCD Transmitter
2-wire pH/ORP Transmitter with Display
Technology Made Easy . . .
68X216829 03/02 version 1
Preface
This manual serves to explain the use of the pH 500 transmitter. It functions in two ways, firstly as a step by step guide to help you to operate the transmitter. It is written to cover as many anticipated applications of the transmitter as possible. If there are doubts in the use of the transmitter, please do not hesitate to contact the nearest Authorized Distributor. [. . . ] Press ENTER key to return to MEAS mode.
3.
CAL
READY
HOLD
R. mV
4.
4. 4
Temperature Calibration
Only available in the pH mode and ATC probe is available. Calibrate temperature probe only if temperature value displayed on transmitter is different from that of a calibrated thermometer. Temperature readings are only displayed Please refer to section 6. 3. 1 for further information.
10
5
ADVANCED SETUP FUNCTIONS
The advanced setup mode lets you customize your transmitter's preferences and defaults. This transmitter features different sub groups that organize all setup parameters. The sub-groups are:
5. 1
Offset Setting (Unavailable in ORP mode)
As a result of the continuous measurement and the application concerned, it may not be convenient to remove the electrode for calibration. Upper display shows amount of offset, in terms of pH; lower display shows current measured pH value. As the lower measured reading changes, upper display records the amount of offset. Press both or keys together to return to ` MEAS ` mode.
SETUP
HOLD
2.
SETUP
READY
HOLD
.
.
pH
pH
3.
11
5. 2
Output Range Setting
SETUP
HOLD
Output of pH 500 transmitter is via the 2-wire power supply loop. Both the 4 mA and 20 mA output can be assigned to specific pH or ORP values, for a more refined output. Press ENT key and use or keys to scroll till LCD displays `r n g '. Upper display shows pH value, `0. 00' (or 1000 mV) while lower display shows `r 4. 0'. Upper display shows pH value, '14. 00' (or 1000 mV) while lower display shows `r 20. 0'.
2.
3. Press ENT key.
o
C'.
6.
Press
and
keys together, to return to MEAS mode.
The transmitter will now compensate pH readings for the manually set temperature (values taken from P oC).
SETUP
HOLD
SETUP
HOLD
SETUP
HOLD
SETUP
HOLD
SETUP
.
.
HOLD
ATC
.
SETUP
HOLD
.
Temperature Compensation Setting Chart alpha pH 500 Transmitter
14
5. 4
SETUP
HOLD
HOLD Current Setting
When Transmitter is in CAL or SETUP modes, it automatically goes into a `HOLD' mode. To indicate Transmitter is in `HOLD' mode, output current can be set to 22 mA output by activating the `HLD On'.
1.
SETUP
HOLD
Press ENT key and use or keys to scroll till LCD displays `SEt' in the upper display; and `HLd' in the lower display. Press ENT to accept selection.
2.
SETUP
HOLD
3.
measured value.
Press
and
keys together, to return to MEAS mode.
NOTE: If `HLd' is set to `OFF', then current output will be equivalent to last
5. 5
SETUP
HOLD
Out-of-Range Current Setting
If pH or ORP readings exceed the scale, LCD displays `Or' (over-range), or `Ur' (under-range). Transmitter current output can be set to 3. 8 mA to indicate Out-of Range situation.
1.
SETUP
HOLD
Press ENT key and use or keys to scroll till LCD displays `SEt' in the upper display; and `org' in the lower display. Press ENT to accept selection.
2.
SETUP
HOLD
3.
Press
and
keys together, to return to MEAS mode.
NOTE: If `org' is set to `OFF', under-range will be set at 4 mA, while overrange will be set at 20 mA.
15
5. 6
5. 6. 1
Configuration
Selecting pH or ORP Mode of Operation
SETUP
HOLD
The alpha pH 500 transmitter is not only a pH transmitter, but also an ORP transmitter. When configured to measure ORP, electrode must be changed and calibrated (see Section 5. 3 for calibration procedure). 2.
Press ENT key and use or keys to scroll till LCD displays `COF' (Configuration). Use or keys to change from `PH' to `ORP', if this Transmitter is to operate as an ORP Transmitter.
SETUP
HOLD
3. Press and keys together, to return to MEAS mode.
SETUP
HOLD
If the readings on the Transmitter is fluctuating wildly, please proceed to Section 6. 6. 2, for a possible solution.
5. 6. 2
Selecting Asymmetrical or Symmetrical Mode of Operation
In some applications, there may be some electrical interference in the sample, where the electrode is installed. The sensitive electrode picks up the signal and the effect is displayed on the LCD. [. . . ] EC-PHCTP0500 EC-ARTSO-05B EC-ARGTSO-05B EC-100GTSO-05B EC-DA93506-05B EC-HTAUTSO-05B EC-HTPTTSO-05B Item Alpha pH/ORP 2-wire LCD Transmitter Combination pH electrode with 5m cable Combination pH electrode with PMP and 5m cable Combination pH electrode with PT 100, PMP and 5m cable Combination pH electrode, submersible, with 5m cable Combination Gold ORP electrode with PMP and 5m cable Combination Platinum ORP electrode with PMP and 5m cable
Calibration Solutions
Ordering Code No. EC-BU-4BT EC-BU-7BT EC-BU-10BT EC-BU-4BS EC-BU-7BS EC-BU-10BS EC-RIN-WT EC-AST-PK EC-DPC-BT EC-RE-005 Item pH 4. 01 buffer solution, 480 ml bottle pH 7. 00 buffer solution, 480 ml bottle pH 10. 01 buffer solution, 480 ml bottle pH 4. 01 buffer sachets, 20 ml x 20 pcs. pH De-ionized water rinse sachets, 20 ml x 20 pcs pH sachet assortment pack 5 each of pH 4. 01, pH 7. 00, pH 10. 01 and deionized water sachets per box. Protein cleaning solution for pH electrode Storage solution for pH electrode
Note: pH buffer solutions (480-ml bottle) have ±0. 01 pH accuracy at 25 °C. [. . . ]