User manual EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER. We hope that this EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER user guide will be useful to you.


EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER : Download the complete user guide (731 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual lpha CON 2000 Conductivity/ Total Dissolved Solids Controller / Transmitter Technology Made Easy . . . 68X216843 Rev 1 01/04 Preface This manual serves to explain the use of the lpha CON 2000 Series. The manual functions in two ways, firstly as a step by step guide to help the user operate the instrument, and secondly as a handy reference guide. This instruction manual is written to cover as many anticipated applications of the lpha CON 2000 as possible. If you have any doubts concerning the use of the instrument, please do not hesitate to contact the nearest Eutech Instruments Authorised Distributor. [. . . ] The transmitter returns to the Measurement mode and the old calibration values remain active. The calibration security code automatically resets from "11" to "000" after the transmitter returns to Measurement mode. 16 Instruction Manual lpha CON 2000 5. 2 Calibration This transmitter features a one-point calibration. Note: The calibration is always carried out in the specific range selected. SETUP HOLD ENT HOLD HOLD CAL ENT HOLD CAL µs ENT HOLD CAL ENT MEAS µs °C 4 4 4 4 ATC 4 CAL °C 4 ATC HOLD 4 1. The display momentarily shows the cell type ("2 CELL" or "4 CELL") to which the transmitter is configured before displaying the last set cell constant (k) Important: If set for a 2 cell operation, make sure that the outer and inner electrode points are shorted on the connector (pins 15 and 16 shorted and pins 17 and 18 shorted). Immerse the sensor in a suitable standard solution, whose value is within the measurement range selected in the transmitter. Note: The calibration standard must have a value that is 10% to 100% of full scale of the range selected. For example, if the range in the controller is selected to be 2000 µS (range 4), then the calibration standard value should be 200 µS to 2000 µS. The display then shows the current measured value of the calibration standard solution. Once the reading stabilises press the or key to adjust the measured value to that of the standard solution. Note: The acceptable calibration window is ±40% of the displayed (default) value. If the display is 1000 µS, the values to which it can be adjusted is 600 to 1400 µS. If there is a calibration error the transmitter displays "ERR" and return to the measurement mode. This serves as a diagnostic feature to indicate the effectiveness of the electrode which will degrade with time and usage. An effective electrode should be within the calibration factor window of 0. 60 to 1. 40. Press the ENT key to return to the Measurement mode. 17 Instruction Manual lpha CON 2000 Note: If you entered the Calibration mode from the Setup mode, the transmitter will return to the setup menu. Note: When calibrating with manual temperature compensation, the transmitter automatically changes from the preset process temperature to the calibration temperature. After leaving the Calibration mode, the transmitter switches back to the process temperature (for setting the calibration temperature and the process temperature, see section 6. 3). 5. 3 View actual cell constant and calibration factor MEAS µS °C 4 CAL ENTER ENT CAL 4 ENT ENTER CAL HOLD ENT 4 1. An effective electrode should be within the calibration factor window of 0. 60 to 1. 40. Press the ENT key to return to the Measurement mode. 18 Instruction Manual lpha CON 2000 6 6. 1 MEAS SETUP MODE Enter Setup mode µS In the Setup mode the transmitter can be configured to your individual requirements. Set the security code with or key to: - "SCD 22" if you want to change parameter settings 4 °C 4 ENTER ENT ENT ENTER SETUP HOLD ENT 4 - "SCD 000" if you want to view only parameter settings (view only mode) 3. Temperature settings see section 6. 3 SETUP HOLD ENT Press the ENT key 4 SETUP HOLD ENT 4 Relay A (set point 1) settings see section 6. 4 SETUP HOLD ENT 4 Relay B (set point 2) settings see section 6. 4 SETUP HOLD ENT 4 Controller settings see section 6. 5 SETUP HOLD ENT 4 Current output 1 settings see section 6. 6 SETUP HOLD ENT 4 Current output 2 settings see section 6. 7 SETUP HOLD ENT 4 Wash contact settings see section 6. 8 SETUP HOLD ENT 4 Range settings see section 6. 9 SETUP HOLD ENT 4 Unit settings see section 6. 10 SETUP HOLD ENT 4 CAL Calibration see section 5 Note: Note: to exit Setup mode at any time press the and key simultaneously (escape). The transmitter returns to the Measurement mode. 19 Instruction Manual lpha CON 2000 6. 2 Temperature compensation (TC) sub-function This sub-function allows you to select the correct temperature compensation for optimum operations. SETUP HOLD ENT SETUP HOLD ENT SETUP HOLD ENT SETUP HOLD 4 4 4 ATC 4 ATC °C SETUP HOLD ENT 4 1. Selecting type of temperature compensation: press the or key to select the suitable type of temperature compensation: - PUR TC = Pure water temperature compensation Use pure water temperature compensation for applications in the pure water or ultrapure water industries. [. . . ] will determine if the product problem is due to deviations or customer abuse. Out-of-warranty products will be repaired on an exchange basis at cost. 10. 2 Packaging / Scope of delivery The instrument is packaged in a corrugated box with an instruction manual and the following accessories: Wall mount version: · · · Plug, nylon, black, 2 pcs PG13. 5, cable gland, 3 pcs Connectors, one each of 3 way (5. 08 mm), 9 way (5. 08mm), 13 way (3. 5mm), 8 way (3. 5mm) Panel mount version: · · · · Rubber gasket, 1pc Catch, 2pcs Rod, thread, 2 pcs Connector, one each of 19 way (3. 5 mm), 5 way (5. 08 mm) and 9way (5. 08 mm) 10. 3 Return of goods Before returning goods for any reason whatsoever, Customer Service Dept. Items must be carefully packed to prevent damage during shipment, and insured against possible damage or loss. Eutech Instruments will not be responsible for any damage resulting from careless or insufficient packing. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.