User manual DSC LCD-600

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DSC LCD-600. We hope that this DSC LCD-600 user guide will be useful to you.


DSC LCD-600 : Download the complete user guide (135 Ko)

Manual abstract: user guide DSC LCD-600

Detailed instructions for use are in the User's Guide.

[. . . ] 1645 Flint Road, Downsview, Ontario, Canada M3J 2J6 Printed in Canada 29000144 R1 LCD-6OO SECURITY STATION Table of Contents Introduction About Your Security System Trouble and Armed LED Displays System Information Master Code Description Arming "At-Home" Arming Split Arming the Panel Disarming If an Alarm Sounds Alarm Memory Display Zone Bypassing Viewing Trouble Conditions LCD-600 Controls and Display Description Testing Keypad Zones Quick-Arm Feature Door Chime Feature Alarm Test Programming Security Codes Master Code Additional Codes One-Time Use Code Fire Alarm Operation Fire Safety in the Home Household Fire Safety Audit Family Escape Planning Maintenance Limited Warranty 1 1 2 3 4 4 5 5 5 6 6 6 7 8 10 11 11 12 12 13 13 13 14 15 15 15 16 Maintenance With normal use, the system requires minimum maintenance. Light dusting with a barely damp cloth should remove normal accumulations of dust. The battery/ bell test is designed to determine battery condition, however it is recommended that the stand-by batteries be replaced every three years. For other system devices such as smoke detectors, passive infrared, ultrasonic or microwave motion detectors or glassbreak detectors, consult the respective manufacturer's literature for testing and maintenance. Limited Warranty Digital Security Controls Ltd. [. . . ] Check to see which zones are bypassed and that these zones are intentionally bypassed. If a trouble is present, see the section "Viewing Trouble Conditions". If this display is showing, there are no troubles or bypassed Enter Code to Arm System zones and the system may be fully armed. If the security code was incorrectly entered, the keypad sounder will beep steadily for two seconds and the display will not change. Exit Delay in Once the correct security code has been entered, the display Progress will be as shown on the left. Exit the premises through the door indicated by your installer as the "exit-entry" door. Once the "exit" delay expires, the system will be armed and will display the following message Enter Code to Disarm System Enter Code to Arm System <> Enter Master Access Code. . . Select Code< > Code 1 P Select Code< > Code 01 P Enter 4 Digit Access Code. . . Enter your current Master Code. Once the new code is entered the keypad sounder will beep 3 times and the display will read. . Remember to record your new Master Code on the System Information page in this booklet. Select Code Code 01 <> P Additional Codes · PC1500 and PC1550 Control Panels Up to 5 additional user codes (2 through 6) may be programmed. · PC2500 Control Panel Up to 7 additional user codes (2 through 8) may be programmed. · PC 2550 and 3000 Control Panels Up to 15 additional user codes (2 through 16) may be programmed. To erase, add or change a user code, press [D] to enter the "functions" list. Press (5) Access Code. . . If you enter your security code with one or more zones bypassed, the following message will appear as soon as you enter the first digit. D WARNING D If this message appears, ensure that the zones bypassed are Bypass Active intentionally bypassed. If you enter your security code and a system trouble is present, the following message will appear as soon as you enter the first digit. If this message appears, check to see what the trouble D WARNING D System Trouble condition is and call for service. If you arm the system with a zone bypassed or with a trouble present your security protection is reduced. Enter Master Access Code. . . Enter Master Code. <> Display will read Select Code Code (x) or Select code Code (xx) <> 13 Door Chime Feature The Door Chime feature provides a tone from the security station each time a monitored door or window is opened or closed. The zones which will activate the Door Chime must be programmed by your installer. If zones have been programmed to initiate the Door Chime, you may enable or disable the feature. Start with the panel in the disarmed mode, press [D] to enter the function list, then scroll to find "User Functions". [. . . ] Restore the sensor to normal, close door/window or stop motion, and the LCD display will return to the disarmed state. Arm then quickly disarm the panel to silence the signal and return to the disarmed state. If the FIRE zone is enabled, activation will cause the signal to sound pulsing. Caution: Do not use open flame or burning materials to test a smoke detector. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DSC LCD-600




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DSC LCD-600 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.