User manual CDA CTE6

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CDA CTE6. We hope that this CDA CTE6 user guide will be useful to you.


CDA CTE6 : Download the complete user guide (473 Ko)

Manual abstract: user guide CDA CTE6

Detailed instructions for use are in the User's Guide.

[. . . ] UK COOKER HOOD USER INSTRUCTIONS DEU DUNSTABZUGSHAUBE GEBRAUCHSANWEISUNG FRA HOTTE PER CUISINE M A N U E L D U T I L I S AT I O N NLD AFZUIGKAP GEBRUIKSAANWIJZING ESP CAMPANA EXTRACTORA MANUAL DE UTILIZACION PRT COIFA ASPIRANTE MANUAL DO USURIO ITA CAPPA ASPIRANTE MANUALE DUSO SVE BR U K S A N V I S N I N G NOR VENTILATOR BRUKERVEILEDNING DNK BRUGERVEJLEDNING FIN LIESITUULETIN K Y TT O H J E GRC OPORROFHTHRAS ODHGIES CRHSEWS RUS C O POL OKAPA INSTRUKCJE UZYTKOWNIKA CZE ODSAVAC NVOD K POZIT HUN PARAELSZIV HASZNLATI TMUTAT ARE 3LI0SLIM3. 1 Fig. 1 165 135 30 12 440 512 / 812 21. 5 469 / 769 21. 5 31 290 270 600 / 900 150 80 339 259 229 31 131 258 120 65 77. 5 30 43. 5 21. 5 89. 5 512 / 812 469 / 769 21. 5 43. 5 31 12 440 65 290 22 600 / 900 131 258 Fig. 2 G A B P L P Fig. 3 Fig. 4 B B 40 4 440 max 80 cm 2 ENGLISH GENERAL ENGLISH RECIRCULATION To transform the cooker hood from the extraction version to the re circulating one ask your supplier for an activated carbon filter. This filter is not washable or re-usable and must be substituted at least every 4 months. Saturation of the activated charcoal depends on how often the appliance is used, the type of kitchen and how regularly the grease filter is cleaned. [. . . ] It is recommended to leave the appliance in operation for 15 minutes after cooking is terminated in order to completely eliminate cooking vapours and odours. The proper function of the cooker hood is conditioned by the regularity of the maintenance operations, in particular, the active carbon filter. The anti-grease filters capture the grease particles suspended in the air, and are therefore subject to clogging according to the frequency of the use of the appliance. In order to prevent fire hazard, it is recommendable to clean the filter at a maximum of 2 months by carrying out the following instructions: - Remove the filters from the cooker hood and wash them in a solution of water and neutral liquid detergent, leaving to soak. The active carbon filters purify the air that is replaced in the environment. The filters are not washable nor re-useable and must be replaced at maximum every four months. The saturation of the active carbon filter depends on the frequency of use of the appliance, by the type of cooking and the regularity of cleaning the anti-grease filters. Clean the fan and other surfaces of the cooker hood regularly using a cloth moistened with denatured alcohol or non abrasive liquid detergent. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR EVENTUAL DAMAGES CAUSED BY BREACHING THE ABOVE WARNINGS. INSTALLATION INSTRUCTIONS Electric Connection The appliance has been manufactured as a class II, therefore no earth cable is necessary. The connection to the mains is carried out as follows: BROWN = L line BLUE = N neutral If not provided, connect a plug for the electrical load indicated on the description label. Where a plug is provided, the cooker hood must be installed in order that the plug is easily accessible. An omnipolar switch with a minimum aperture of 3mm between contacts, in line with the electrical load and local standards, must be placed between the appliance and the network in the case of direct connection to the electrical network. The appliance must be installed at a minimum height of 650 mm from an cooker stove. If a connection tube composed of two parts is used, the upper part must be placed outside the lower part. [. . . ] When mounting align the front of the cooker hood to the door of the cupboard and regulate the L wall spacer through the screws marked P (Fig 2). EXTRACTION THROUGH AN OUTSIDE WALL The appliance expels the fumes through an outside wall or a duct. It is necessary to buy a telescopic pipe in accordance with the standards in use (inflammable with diameter 120mm) and connect it to flange B (Fig 3). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CDA CTE6




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CDA CTE6 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.