User manual BOSCH PCL 10 REV 6-2008

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BOSCH PCL 10. We hope that this BOSCH PCL 10 user guide will be useful to you.


BOSCH PCL 10 REV 6-2008: Download the complete user guide (3336 Ko)

Manual abstract: user guide BOSCH PCL 10REV 6-2008

Detailed instructions for use are in the User's Guide.

[. . . ] IEC 60825-1: 2007-03, < 1 mW, 635 nm Laser Radiation Do not stare into beam Class 2 laser product Have the measuring tool repaired only through qualified specialists using original spare parts. Do not allow children to use the laser measuring tool without supervision. [. . . ] Please observe the article number on the type plate of your measuring tool. When inserting, pay attention to the correct polarity according to the representation on the inside of the battery compartment. Remove the batteries from the measuring tool when not using it for extended periods. When storing for extended periods, the batteries can corrode and discharge themselves. 12 | English Working with Automatic Levelling (see figures A­B) Position the measuring tool on a level and firm support, hold it by the contact surfaces 6 against a vertical surface or attach it to a tripod 11. After switching on, the levelling function automatically compensates irregularities within the self-levelling range of ±4°. The levelling is finished as soon as the laser beams do not move any more. Because the surface on which the measuring tool stands deviates by more than 4° from the horizontal plane, the indicator 2 lights up red and the laser is automatically switched off. In this case, bring the measuring tool to the level position or hold it by the contact surfaces 6 straightly against a vertical surface, and wait for the selflevelling to take place. As soon as the measuring tool is within the self-levelling range of ±4° again, the indicator 2 lights up green and the laser beams are switched on. When not within the self-levelling range of ±4°, working with the measuring tool is not possible, because it cannot be assured that the laser beams run at a right angle to each other. In case of ground vibrations or position changes during operation, the measuring tool is automatically levelled in again. To avoid errors, check the position of the horizontal and vertical laser line with regard to the reference points upon re-levelling. Laser viewing glasses (Accessory) The laser viewing glasses filter out the ambient light. [. . . ] Only for EC countries: Defective or dead out battery packs/batteries must be recycled according the guideline 91/157/EEC. Batteries no longer suitable for use can be directly returned at: Great Britain Robert Bosch Ltd. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BOSCH PCL 10




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BOSCH PCL 10 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.