User manual BOSCH GWS 11-125 CI

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BOSCH GWS 11-125 CI. We hope that this BOSCH GWS 11-125 CI user guide will be useful to you.


BOSCH GWS 11-125 CI : Download the complete user guide (8475 Ko)

Manual abstract: user guide BOSCH GWS 11-125 CI

Detailed instructions for use are in the User's Guide.

[. . . ] In the Commonwealth of Massachusetts this product must be installed by a licensed plumber or gas fitter. Upon completion of the installation, these instructions should be handed to the user of the appliance for future reference. · Do not try to light any appliance · Do not touch any electrical switch; do not use any phone in your building. · Immediately call your gas supplier from a neighbor's phone. [. . . ] Its purpose is to ensure that the hot water temperature will remain steady, although the water flow demand might vary. The output temperature can be adjusted with either the temperature adjustment knob or the gas control slide. Temperature adjustment knob The temperature adjustment knob on the front bottom of the heater (see Fig. See table 4 for details. The hottest position is the highest flame position all the way to the right. Fig. 25 4. 5 Draining water from heater If there is a risk of freezing, proceed as follows: B Remove the retaining clip from threaded bushing (pos. 23 Knob position Degree rise Activation rate Max flow rate Clockwise 90°F 0. 5 GPM 2. 0 GPM Counterclockwise 45°F 1. 1 GPM 3. 7 GPM B Empty the appliance of all water. Table 4 Temperature rise (slide control to the right) As the temperature adjustment knob is turned counterclockwise, the output temperature will lower and the activation rate will be raised. Turning the knob clockwise will raise the temperature and lower the activation rate. Gas control slide button The gas control slide button adjusts temperature by adjusting how much gas is allowed to flow to the burners. As the slide is adjusted to the left, the output temperature will lower, with the lowest setting being the small flame position. Fig. 26 Drain plug and filter location 1 2 Retaining clip Threaded bushing Fig. 24 16 6 720 608 034 Maintenance and service 5 5. 1 Maintenance and service Maintenance intervals Warning: Failure to perform recommended maintenance may result in complete failure of the unit over time. Shut off the installer supplied cold water isolation valve to the heater. Position a bucket under the heater's water valve assembly to catch any water that may drain from the heater. Disconnect the water pipe leading out of water valve to the heat exchanger. Do this by removing the retaining 6 720 608 034 17 Maintenance and service 5. 4 Main burners The main burner flames should be blue, with a more intense blue cone in the center core. Yellow flames could be a sign of wrong size gas orifices or dirty burners, a blockage on the heat exchangers fins. If some burners have yellow flames while others have blue flames, it is likely that dust, lint or spider webs have partially clogged the burner venturis. Run solution through the heat exchanger until the solution returning to the descaling reservoir comes out clear. Position a container below the hot water outlet and connect cold water supply. Open cold water supply isolation valve and flush heat exchanger with clean water. Shut cold water isolation valve and reconnect hot water supply to the water heater. Reconnect electrical supply to unit, open water isolation valves, and return the unit to service. 5. 5 Vent assembly Inspect the draft hood and heat exchanger fins for signs of soot build-up or any other foreign material such as spider webs. [. . . ] At below freezing temperatures, disconnect the plumbing connections to the heater and allow the heater to drain. To prevent any freeze damage, introduce short bursts of compressed air (20-40 psi) through these connections to remove the residual water in the horizontal pipes and water valve. Follow instructions in chapter 4. 5 to remove any additional water remaining in the watervalve and heat exchanger. 6 720 608 034 23 Interior components and diagram parts list 8 8. 1 Interior components and diagram parts list Interior components Fig. 28 Functional scheme 4 5 10 11 20 Heat exchanger Burner Temperature adjustment selector Water valve Gas connection 22 26 30 102 Flexible hot outlet Gas control slide Pilot gas tubing Piezo 24 6 720 608 034 Interior components and diagram parts list 8. 2 Components diagram 5 4 6 44 41 8 48 47 50 39 14 12 13 15 19 18 43 16 20 11 24 10 9 21 23 51 27 22 7 38 25 52 17 30 28 26 31 35 13 29 32 45 46 34 42 36 49 3 2 1 33 37 40 6720608126-02. 1 JF Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BOSCH GWS 11-125 CI




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BOSCH GWS 11-125 CI will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.