User manual AEG-ELECTROLUX LUX CAG1500
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX LUX CAG1500. We hope that this AEG-ELECTROLUX LUX CAG1500 user guide will be useful to you.
You may also download the following manuals related to this product:
AEG-ELECTROLUX LUX CAG1500 (268 ko)
Manual abstract: user guide AEG-ELECTROLUX LUX CAG1500
Detailed instructions for use are in the User's Guide.
[. . . ] Complete, Easy To Read
INSTALLATION AND OPERATING INSTRUCTIONS
SMART TEMP ELECTRONIC THERMOSTAT
PM
4. Position the base for best appearance (to hide any marks from an old thermostat). Attach the base to the wall with the two screws provided.
CONNECTING THE WIRES
5. These diagrams are provided for new installations or unreferenced wires.
CAG1500 SERIES
SET SUNDAY
HEAT OFF
WEEKDAY PROGRAM SET DAY/TIME
COOL
Easy as 123
HEATING SYSTEMS
JUMPER PROVIDED
COOLING SYSTEMS
JUMPER PROVIDED
G
Y
W RH RC
B
O
G
Y
W RH RC
B
O
Installs Easily
Set Day and Time
Choose Heat or Cool
LUX PRODUCTS CORPORATION Mt. [. . . ] To minimize the risk of damaging the unit in extremely dry weather, touch a grounded metal object before touching your thermostat.
FAN A/C COMPRESSOR 24 VOLT COOLING TRANSFORMER
120 VAC
INSTALLATION
Please read all instructions carefully before beginning installation.
4 WIRE SYSTEM HEATING AND COOLING
CAUTION
Turn off electricity to the appliance before installing or servicing thermostat or any part of the system. G Do not short (jumper) across electric terminals on furnace or air conditioner to test the system. G The thermostat should be limited to a maximum of 1. 5 amps; higher current may cause damage to the thermostat. Please handle it with care.
G
Y
W
RH
RC
B
JUMPER
O
3. The HEAT or COOL set temperature will be displayed on the right side of the display. The start time for the displayed period will flash to show that this may be changed. The beginning of that period may not be any closer to the beginning of the next period than one 15 minute increment. Press NEXT to accept the displayed start time and advance to edit the SET TEMPERATURE. Use the UP/DOWN arrow keys to change the flashing HEAT or COOL set temperature to the temperature you desire. Press NEXT to accept the displayed set temperature and advance to edit the start time for the next period. The table pictured on the right is also OPEN CLOSE printed on the circuit board. The closed or J4 ELECT GAS shorted position is that which covers both a J3 2MIN 5MIN jumpers pins. To prevent its loss, a jumper F C J2 may be placed over one pin only for the J1 24HR 12HR open positions. After settings have been changed, press S8, the HARDWARE RESET button for the changes to take effect. See HARDWARE RESET
THERMOSTAT LOCATION
On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. Do not install it where there are unusual heating conditions, such as: in direct sunlight; near a lamp, television, radiator, register, or fireplace; near hot water pipes in a wall; near a stove on the other side of a wall. Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room; or in a draft from a stairwell, door, or window. Do not locate where air circulation is poor, such as: in a corner or an alcove; or behind an open door. Do not install the unit until all construction work and painting has been completed.
FAN COOLING HEAT
COPY BUTTON
COPY will copy the previous day's Heat, Cool or Fan program into the current day and advance to the beginning of the next day.
DAY PERIOD MORN HEAT COOL TIME TEMP. TIME TEMP.
24 VOLT 24 VOLT HEAT COOL TRANSFORMER TRANSFORMER
120 VAC 120 VAC
DAY PERIOD MORN HEAT COOL TIME TEMP. TIME TEMP.
THURS
DAY EVE NIGHT MORN DAY EVE NIGHT MORN DAY EVE NIGHT MORN DAY EVE NIGHT
SINGLE STAGE HEAT PUMP SYSTEM
BATTERIES AND MAINTENANCE
INSTALLING BATTERIES/ MAINTENANCE
The CAG1500 requires batteries to operate your heating/cooling system. Replace the batteries when the battery REPLACE indicator appears in the display or at least once a year. [. . . ] Rotate the dial back to RUN to accept all current values and end the programming session.
6:00
TECHNICAL ASSISTANCE
If you have any problems installing or using this thermostat, please reread the instructions carefully or visit our online technical support at www. luxproducts. com. Technical assistance is available through our Technical Service Number. Fill wall opening with noncombustible insulation to prevent drafts from affecting the thermostat.
NOTE
WARRANTY
Limited Warranty: If this unit fails because of defects in materials or workmanship within one year of date of original purchase, LUX will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX LUX CAG1500
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX LUX CAG1500 will begin.