User manual AEG-ELECTROLUX DK9660-MR

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX DK9660-MR. We hope that this AEG-ELECTROLUX DK9660-MR user guide will be useful to you.


AEG-ELECTROLUX DK9660-MR : Download the complete user guide (508 Ko)

You may also download the following manuals related to this product:

   AEG-ELECTROLUX DK9660-MR (513 ko)
   AEG-ELECTROLUX DK9660-MR (502 ko)
   AEG-ELECTROLUX DK9660-MR (489 ko)
   AEG-ELECTROLUX DK9660-MR (527 ko)

Manual abstract: user guide AEG-ELECTROLUX DK9660-MR

Detailed instructions for use are in the User's Guide.

[. . . ] The premises where the appliance is installed must be sufficiently ventilated, when the kitchen hood is used together with other gas combustion devices or other fuels. The ducting system for this appliance must not be connected to any existing ventilation system which is being used for any other purpose such as discharging exhaust fumes from appliances burning gas or other fuels. The use of exposed flames is detrimental to the filters and may 56 Cause a fire risk, and must therefore be avoided in all circumstances. Any frying must be done with care in order to make sure that the oil does not overheat and ignite. [. . . ] In this mode fumes are extracted to the outside via a hose connected to the coupling ring. In order to obtain the best performance the hose should have a diameter equal to the outlet hole. The air is filtered through a charcoal filter and returned to the kitchen. You will need an original charcoal filter for the recirculation mode. Best results are obtained by using a low speed for normal conditions and a high speed when odours are more concentrated. The hood should be left on after cooking for about 15 minutes or until all the odours have disappeared. The cooker hood is fitted with a sensor which, in the event of extreme variations in temperature, switches the appliance on automatically until the temperature of the environment surrounding the hood has been significantly reduced. The control switches are located on the unit's front panel: 1 Motor ON/OFF button By pressing the button, the hood starts at speed 1. Pressing the button (OFF) while the hood is in function turns the latter off. 2 Speed increase button By pressing the button, the hood starts at speed 1. Pressing the button (while the hood is on) modifies the motor speed: Speed 1: the number "1" appears on the display Speed 2: the number "2" appears on the display Speed 3: the number "3" appears on the display High-speed: the number "4" appears (flashing) on the display The high-speed function is regulated by a timer. The charcoal filter should only be used if you want to use the hood in recirculation mode. To do this you will need an original charcoal filter (available from your local Service Force Centre). Replacing the charcoal filter The charcoal filter cannot be washed nor regenerated. The charcoal filter should be replaced every 4 months under normal use. Replacement filters are available from your local Service Force Centre. Fitting Position the carbon filter inside the hood to cover the protection grill of the motor. Always specify the hood model number, serial number and product number code when ordering replacement filters. This information is shown on the rating plate located on the inside of the unit. The charcoal filter can be ordered from your local Service Force Centre. The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations. If the light does not come on, make sure the bulb has been inserted in correctly before contacting your local Service Force Centre. [. . . ] Safety warnings for the electrician The mains power supply must correspond to the rating indicated on the plate situated inside the hood. If provided with a plug connect the hood to a socket in compliance with current regulations and positioned in an accessible area. If it not fitted with a plug (direct mains connection) or if the plug is not located in an accessible area apply a double pole switch in accordance with standards which assures the complete disconnection of the mains under conditions relating to over-current category III, in accordance with installation instructions. Before re-connecting the hood circuit to the mains supply and checking the efficient function, always check that the mains cable is correctly assembled. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX DK9660-MR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX DK9660-MR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.