User manual AEG-ELECTROLUX DF6163-M

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual AEG-ELECTROLUX DF6163-M. We hope that this AEG-ELECTROLUX DF6163-M user guide will be useful to you.


AEG-ELECTROLUX DF6163-M : Download the complete user guide (2490 Ko)

Manual abstract: user guide AEG-ELECTROLUX DF6163-M

Detailed instructions for use are in the User's Guide.

[. . . ] The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed. The air outlet installation must comply with the regulations laid down by the relevant local authorities. When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole. National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room. [. . . ] You will need an original charcoal filter for the recirculation function. The numbers and symbols have the following meanings (from left to right): The extractor part (visor) of the hood is used to switch the fan on and off when the appliance is switched on (Motor). The lighting can be separately switched on and off with the slide switch. Turn the hood on a few minutes before you start cooking then you will get an underpressure in the kitchen. It should be left on after cooking for about 15 minutes or until all odours have disappeared. The hood must always be disconnected from the electricity supply before beginning any maintenance work. Clean the outside of the hood using a damp cloth and a mild washing up liquid solution. Only ever clean the switch panel and filter grill using a damp cloth and mild washing up liquid solution. It is extremely important to clean the unit and change the filters at the recommended intervals. Failure to do so will cause grease deposits to build up that could constitute a fire hazard. The purpose of the grease filters is to aspirate grease particles which form during cooking and it must always be used, either in the extraction or internal recirculation function. Close the bulb cover and relock it by twisting the bolts to the right. If the light does not come on, make sure the bulb has been inserted correctly before contacting your local Service Force Centre. Contact our Service Force Centre Available from your retailer as an accessory Available from your retailer as an accessory ET-NR. If your appliance fails to work properly please carry out the following checks. Check that a fan speed has been selected Check that: The fan speed is set high enough for the task. If the hood has been installed below the heights indicated in the installation instructions the motor will cut-out frequently which will damage the hood. If after all these checks, the problem persists, contact your local Service Force Centre, quoting the model and serial number. Please note that it will be necessary to provide proof of purchase for any in-guarantee service calls. In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown. You are welcome to telephone our technical assistance service (see list of technical assistance centres) whenever you need information or in the unlikely event of a fault. ) This information is shown on the registration plate inside the unit behind the grease filter. [. . . ] 5 Preparing the wall unit - Filter version (DF 6160) Before installation of the hood in the wall unit, a 115x115 mm hole for the deflector should be cut in the ceiling of the wall unit. Depending on the wall unit height, you need for return air operation a pipe union or additionally a non-flammable length of pipe (Ø 100/115/ 120 mm) as far as the ceiling of the wall unit. Outlet hole - Only for models DF 6261 (extractor-filter version) When used as an extractor unit, the hood must be fitted with a 150mm diameter hose. Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof, it is possible to use the 150/125 mm reduction flange provided. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX DF6163-M




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX DF6163-M will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.